At GSI the CAPRICE-type ECRIS delivers ion beams to the High Charge State Injector (HLI). Following the demand of high flexibility the ECRIS is operated either in cw mode for high duty cycle beams or in afterglow mode to provide low duty cycle beams for the Heavy Ion Synchrotron (SIS) at low repetition rates in the order of 1 pulse per second. Especially for high Z ions the afterglow mode can provide increased intensities with respect to cw mode in those charge states required for injection (A/q<8.5). Besides the required beam intensity major demands of accelerator injection are good long time stability and good pulse to pulse reproducibility of the ion beam. In order to find the best operating conditions for optimized afterglow performance systematic studies were performed with Xe-136, the heaviest stable rare gas isotope. Different rf pulse conditions (pulse length, repetition rate, pulse shape, duty cycle) were compared. The influence of the ion source parameters on the afterglow mode were studied in comparison to cw mode. (C) 2004 American Institute of Physics.
引用
收藏
页码:1407 / 1409
页数:3
相关论文
共 50 条
  • [1] Investigation of pulsed mode operation with the frequency tuned CAPRICE ECRIS
    Maimone, F.
    Tinschert, K.
    Endermann, M.
    Hollinger, R.
    Kondrashev, S.
    Lang, R.
    Maeder, J.
    Patchakui, P. T.
    Spaedtke, P.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (02):
  • [2] Cyclotron instability in the afterglow mode of minimum-B ECRIS
    Izotov, I.
    Kalvas, T.
    Koivisto, H.
    Komppula, J.
    Kronholm, R.
    Laulainen, J.
    Mansfeld, D.
    Skalyga, V.
    Tarvainen, O.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (02):
  • [3] Experiments on beam extraction from the CAPRICE ECRIS
    Tinschert, K
    Spädtke, P
    Bossler, J
    Iannucci, R
    Lang, R
    Electron Cyclotron Resonance Ion Sources, 2005, 749 : 241 - 241
  • [4] X-ray spectroscopy characterization of Ar17+ produced by an ECRIS in the afterglow mode
    Prigent, C.
    Lamour, E.
    Merot, J.
    Pascal, B.
    Rozet, J. -P.
    Trassinelli, M.
    Vernhet, D.
    Pacquet, J. -Y.
    Maunoury, L.
    Noury, F.
    Ramillon, J. -M.
    14TH INTERNATIONAL CONFERENCE ON THE PHYSICS OF HIGHLY CHARGED IONS (HCI 2008), 2009, 163
  • [5] Research and development activities to increase the performance of the CAPRICE ECRIS at GSI
    Maimone, F.
    Andreev, A.
    Galonska, M.
    Hollinger, R.
    Lang, R.
    Maeder, J.
    Patchakui, P. T.
    20TH INTERNATIONAL CONFERENCE ON ION SOURCES, 2024, 2743
  • [6] EXPERIMENTAL-STUDY ON DEACTIVATION OF XENON METASTABLE ATOMS IN AFTERGLOW
    GERASIMOV, GN
    PETROV, SY
    OPTIKA I SPEKTROSKOPIYA, 1976, 41 (02): : 184 - 188
  • [7] STUDY ON RECOMBINATION IN XENON AFTERGLOW
    GERASIMOV, GN
    KHRYAKOV, BV
    OPTIKA I SPEKTROSKOPIYA, 1975, 39 (03): : 453 - 457
  • [8] Ion beam extracted from a 14GHz ECRIS of CAPRICE type
    Spaedtke, P.
    Lang, R.
    Maeder, J.
    Rossbach, J.
    Tinschert, K.
    Stetson, J.
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2007, 31 : 192 - 195
  • [9] ION CONVERSION IN XENON AFTERGLOW PLASMAS
    Bhattacharya, A. K.
    APPLIED PHYSICS LETTERS, 1970, 17 (12) : 521 - 522
  • [10] STUDY OF XENON FLOWING AFTERGLOW IN VUV
    GERASIMOV, GN
    KRYLOV, BE
    LOGINOV, AV
    SHCHUKIN, SA
    OPTIKA I SPEKTROSKOPIYA, 1985, 59 (04): : 775 - 780