Tuning selectivity in cation-exchange chromatography applied for monoclonal antibody separations, part 2: Evaluation of recent stationary phases

被引:16
|
作者
Murisier, Amarande [1 ]
Farsang, Evelin [2 ]
Horvath, Krisztian [2 ]
Lauber, Matthew [3 ]
Beck, Alain [4 ]
Guillarme, Davy [1 ]
Fekete, Szabolcs [1 ]
机构
[1] Univ Lausanne, Univ Geneva, Sch Pharmaceut Sci, CMU, Rue Michel Servet 1, CH-1211 Geneva 4, Switzerland
[2] Univ Pannonia, Dept Analyt Chem, Egyet U 10, H-8200 Veszprem, Hungary
[3] Waters Corp, 34 Maple St, Milford, MA 01757 USA
[4] Ctr Immunol Pierre Fabre, 5 Ave Napoleon III,BP 60497, F-74160 St Julien En Genevois, France
基金
瑞士国家科学基金会;
关键词
Cation exchange chromatography; pH gradient; Salt gradient; Salt-mediated pH gradient; Monoclonal antibody; Column efficiency; CHARGE VARIANTS; HETEROGENEITY;
D O I
10.1016/j.jpba.2019.05.011
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this second part of the series, recently commercialized cation exchanger stationary phases were systematically investigated for their capabilities to separate therapeutic monoclonal antibodies. It was demonstrated that the different combinations of stationary and mobile phases result in diverse retention, selectivity and efficiency. Hence, the whole phase system (combination of stationary and mobile phase) should be considered when developing a method. In addition, retention behavior is mAb dependent and should be individually optimized. Another interesting observation was that in cation exchange chromatographic separations of large proteins, the particle size of the columns probably impacts retention rather than efficiency, due to the non-porous particle structure- and therefore the higher specific surface area of smaller particles-. Particle size influences the specific surface area and total porosity. Therefore, columns packed with larger particles showed lower retention (when the ion exchanger group was the same e.g. strong exchanger sulfonic group) while no link was observed between efficiency and particle size. The retention, efficiency and selectivity of the studied columns were quite different and strongly dependent on the elution mode (i.e. salt gradient, pH gradient or combined salt/pH gradient mode). The columns can be considered to be complementary, suggesting that it is useful to have more than one type of column on hand while developing new charge variant assays. Moreover, this work shows that it is especially attractive to make use of short, narrow bore ion exchange columns that offer the possibility to perform 4-6 min long separations of both intact and partially digested antibodies. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:320 / 328
页数:9
相关论文
共 39 条
  • [1] Tuning selectivity in cation-exchange chromatography applied for monoclonal antibody separations, part 1: Alternative mobile phases and fine tuning of the separation
    Farsang, Evelin
    Murisier, Amarande
    Horvath, Krisztian
    Beck, Alain
    Kormany, Robert
    Guillarme, Davy
    Fekete, Szabolcs
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2019, 168 : 138 - 147
  • [2] Protein variant separations by cation-exchange chromatography on tentacle-type polymeric stationary phases
    Weitzhandler, M
    Farnan, D
    Horvath, J
    Rohrer, JS
    Slingsby, RW
    Avdalovic, N
    Pohl, C
    JOURNAL OF CHROMATOGRAPHY A, 1998, 828 (1-2) : 365 - 372
  • [3] HYDROPHOBIC CHROMATOGRAPHY WITH DYNAMICALLY COATED STATIONARY PHASES .2. DYNAMIC CATION-EXCHANGE SEPARATIONS OF TYROSINYL PEPTIDES
    WALL, RA
    JOURNAL OF CHROMATOGRAPHY, 1980, 194 (03): : 353 - 363
  • [4] Glycoprotein variant separations using cation-exchange chromatography on grafted, pellicular polymeric stationary phases.
    Weitzhandler, M
    Avdalovic, N
    Farnan, D
    Roehl, R
    Slingsby, R
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2000, 219 : U183 - U183
  • [5] Characterization of cation exchanger stationary phases applied for the separations of therapeutic monoclonal antibodies
    Fekete, Szabolcs
    Beck, Alain
    Guillarme, Davy
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2015, 111 : 169 - 176
  • [6] Cation-exchange separations of C-terminal processing of a humanized monoclonal antibody on a grafted polymeric stationary phase
    Heckenberg, A
    Farnan, D
    Weitzhandler, M
    LC GC NORTH AMERICA, 2002, : 11 - 11
  • [7] Protein variant separations using cation exchange chromatography on grafted, polymeric stationary phases
    Weitzhandler, M
    Farnan, D
    Rohrer, JS
    Avdalovic, N
    PROTEOMICS, 2001, 1 (02) : 179 - 185
  • [8] Glycoprotein variant separations using cation exchange chromatography on grafted, pellicular polymeric stationary phases
    Weitzhandler, M
    Avdalovic, N
    Pohl, C
    GLYCOBIOLOGY, 1999, 9 (10) : 1154 - 1154
  • [9] Evaluation of cation exchange chromatography as a capture step for monoclonal antibody purification
    Lute, Scott
    Miesegaes, George
    Kaushal, Simran
    Strauss, Daniel
    Chen, Dayue
    Shamlou, Parviz
    Brorson, Kurt
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2011, 241
  • [10] Robustness assessment of cation-exchange chromatography with in-silico peak deconvolution in monoclonal antibody purification
    Kitamura, Ryunosuke
    Aiso, Takaki
    Kawatsu, Kosaku
    Masuda, Yumiko
    Kawabe, Takefumi
    Nonaka, Koichi
    Yonemochi, Etsuo
    JOURNAL OF CHROMATOGRAPHY OPEN, 2022, 2