Rational synthesis of rare-earth lanthanum molybdate covered reduced graphene oxide nanocomposites for the voltammetric detection of Moxifloxacin hydrochloride

被引:17
作者
Akilarasan, Muthumariappan [1 ]
Tamilalagan, Elayappan [1 ]
Chen, Shen-Ming [1 ]
Maheshwaran, Selvarasu [1 ]
Fan, Chih-Hsuan [1 ]
Habila, Mohamed A. [2 ]
Sillanpaa, Mika [3 ]
机构
[1] Natl Taipei Univ Technol, Dept Chem Engn & Biotechnol, 1,Sect 3,Chung Hsiao East Rd, Taipei 106, Taiwan
[2] King Saud Univ, Coll Sci, Dept Chem, POB 2455, Riyadh 11451, Saudi Arabia
[3] Aarhus Univ, Dept Biol & Chem Engn, Norrebrogade 44, Aarhus 8000, Denmark
关键词
La-2(MoO4)(3) @rGO nanocomposites; Drug analysis; Moxifloxacin hydrochloride sensor; Binary-metal oxide; Electrochemical sensor; GLASSY-CARBON ELECTRODE; OPHTHALMIC SOLUTION; ELECTROCHEMICAL DETERMINATION; CONTROLLED CONSTRUCTION; MICROARCHITECTURES; PHOSPHORS;
D O I
10.1016/j.bioelechem.2022.108145
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Recently, perovskite structure-based metal oxide nanomaterials and their composites opted for electrocatalyst because of its excellent conductivity, unique, and favored electronic structure. In this attempt, herein we prepared the rare earth mixed metal molybdate covered reduced graphene oxide La-2(MoO4)(3)@rGO nanocomposites by a simple hydrothermal method for the sensitive detection of Moxifloxacin hydrochloride (MOF) in pharmaceutical and human urine samples. The various physicochemical analysis such as SEM, TEM, XRD and Raman spectroscopy confirms the successful formation of (La-2(MoO4)(3)@rGO) nanocomposites. Furthermore, the electroanalytical performance ofLa(2)(MoO4)(3)@rGO modified glassy carbon electrode (La-2(MoO4)(3)@rGO/GCE) was analyzed using the cyclic voltammetry (CV) and differential pulse voltammetry (DPV) which shows excellent results with a wide range of 1.0 x 10(-8) M to 6.0 x 10(-4) M and the detection limit of 2.84 x 10(-9) M towards the MOF detection. Furthermore, the developed sensor expressed good selectivity, repeatability, stability and reproducibility. Finally, the real sample analysis of the developed sensor was tested in the MOF tablets and human urine samples, which shows the appreciable recoveries.
引用
收藏
页数:9
相关论文
共 42 条
[1]   Torsade de pointes associated with moxifloxacin: A rare but potentially fatal adverse event [J].
Altin, Timucin ;
Ozcan, Ozgur ;
Turhan, Sibel ;
Ozdemir, Aydan Ongun ;
Akyurek, Omer ;
Karaoguz, Remzi ;
Guldal, Muharrem .
CANADIAN JOURNAL OF CARDIOLOGY, 2007, 23 (11) :907-908
[2]   Development and validation of sensitive kinetic spectrophotometric method for the determination of moxifloxacin antibiotic in pure and commercial tablets [J].
Ashour, Safwan ;
Bayram, Roula .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2015, 140 :216-222
[3]   Controlled construction of uniform pompon-shaped microarchitectures self-assembled from single-crystalline lanthanum molybdate nanoflakes [J].
Bu, Wenbo ;
Xu, Yunpeng ;
Zhang, Na ;
Chen, Hangrong ;
Hua, Zile ;
Shi, Jianlin .
LANGMUIR, 2007, 23 (17) :9002-9007
[4]   Moxifloxacin-associated neutropenia in a cirrhotic elderly woman with lower extremity cellulitis [J].
Chang, Chia-Ming ;
Lee, Nan-Yao ;
Lee, Hsin-Chun ;
Lee, I-Wen ;
Wu, Chi-Jung ;
Lin, Yu-Shiuan ;
Ko, Wen-Chien .
ANNALS OF PHARMACOTHERAPY, 2008, 42 (04) :580-583
[5]   Controlled construction of monodisperse La2(MoO4)3:Yb,Tm microarchitectures with upconversion luminescent property [J].
Chen, Zhenxing ;
Bu, Wenbo ;
Zhang, Na ;
Shi, Jianlin .
JOURNAL OF PHYSICAL CHEMISTRY C, 2008, 112 (11) :4378-4383
[6]   Enantiomeric purity assay of moxifloxacin hydrochloride by capillary electrophoresis [J].
Cruz, LA ;
Hall, R .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 38 (01) :8-13
[7]   SIMULTANEOUS ESTIMATION OF MOXIFLOXACIN HYDROCHLORIDE AND DEXAMETHASONE SODIUM PHOSPHATE IN BULK AND IN OPHTHALMIC SOLUTION BY RP- HPLC [J].
Dhumal, D. M. ;
Shirkhedkar, A. A. ;
Nerkar, P. P. ;
Surana, S. J. .
JOURNAL OF THE CHILEAN CHEMICAL SOCIETY, 2012, 57 (04) :1344-1347
[8]   A Sensitive Voltammetric Sensor for Improved Simultaneous Determination of Moxifloxacin Hydrochloride and Paracetamol [J].
Essa, W. A. ;
Beltagi, A. M. ;
Hathoot, A. A. ;
Azzem, M. Abdel .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2020, 167 (16)
[9]   A new simple electrochemical Moxifloxacin Hydrochloride sensor built on carbon paste modified with silver nanoparticles [J].
Fekry, Amany M. .
BIOSENSORS & BIOELECTRONICS, 2017, 87 :1065-1070
[10]   A Sensitive Electrochemical Sensor for Moxifloxacin Hydrochloride Based on Nafion/Graphene Oxide/Zeolite Modified Carbon Paste Electrode [J].
Fekrya, Amany M. ;
Abdel-Gawad, Soha A. ;
Azab, Shereen M. ;
Walcarius, Alain .
ELECTROANALYSIS, 2021, 33 (04) :964-974