Comparison of Low-Cost Particulate Matter Sensors for Indoor Air Monitoring during COVID-19 Lockdown

被引:29
作者
Kaliszewski, Miron [1 ]
Wlodarski, Maksymilian [1 ]
Mlynczak, Jaroslaw [1 ]
Kopczynski, Krzysztof [1 ]
机构
[1] Mil Univ Technol, Inst Optoelect, Gen S Kaliskiego 2, PL-00908 Warsaw, Poland
关键词
indoor air; low-cost particle sensors; human activity; aerosol sources; PM; OPTICAL-PARTICLE COUNTER; EXPOSURE; PM2.5; POLLUTION; OUTDOOR; HEALTH; CLEANERS; DISEASES; OPC-N2;
D O I
10.3390/s20247290
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study shows the results of air monitoring in high- and low-occupancy rooms using two combinations of sensors, AeroTrak8220(TSI)/OPC-N3 (AlphaSense, Great Notley, UK) and OPC-N3/PMS5003 (Plantower, Beijing, China), respectively. The tests were conducted in a flat in Warsaw during the restrictions imposed due to the COVID-19 lockdown. The results showed that OPC-N3 underestimates the PN (particle number concentration) by about 2-3 times compared to the AeroTrak8220. Subsequently, the OPC-N3 was compared with another low-cost sensor, the PMS5003. Both devices showed similar efficiency in PN estimation, whereas PM (particulate matter) concentration estimation differed significantly. Moreover, the relationship among the PM1-PM2.5-PM10 readings obtained with the PMS5003 appeared improbably linear regarding the natural indoor conditions. The correlation of PM concentrations obtained with the PMS5003 suggests an oversimplified calculation method of PM. The studies also demonstrated that PM1, PM2.5, and PM10 concentrations in the high- to low-occupancy rooms were about 3, 2, and 1.5 times, respectively. On the other hand, the use of an air purifier considerably reduced the PM concentrations to similar levels in both rooms. All the sensors showed that frying and toast-making were the major sources of particulate matter, about 10 times higher compared to average levels. Considerably lower particle levels were measured in the low-occupancy room.
引用
收藏
页码:1 / 17
页数:17
相关论文
共 57 条
  • [1] Relative contribution of outdoor and indoor particle sources to indoor concentrations
    Abt, E
    Suh, HH
    Catalano, P
    Koutrakis, P
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2000, 34 (17) : 3579 - 3587
  • [2] [Anonymous], 2019, ALPHASENSE LTD OPC N
  • [3] Evaluation of Low-Cost Sensors for Ambient PM2.5 Monitoring
    Badura, Marek
    Batog, Piotr
    Drzeniecka-Osiadacz, Anetta
    Modzel, Piotr
    [J]. JOURNAL OF SENSORS, 2018, 2018
  • [4] Low-Cost Air Quality Sensors: One-Year Field Comparative Measurement of Different Gas Sensors and Particle Counters with Reference Monitors at Tusimice Observatory
    Bauerova, Petra
    Sindelarova, Adriana
    Rychlik, Stepan
    Novak, Zbynek
    Keder, Josef
    [J]. ATMOSPHERE, 2020, 11 (05)
  • [5] Performance evaluation of the cost-effective and lightweight Alphasense optical particle counter for use onboard unmanned aerial vehicles
    Bezantakos, Spyros
    Schmidt-Ott, Fabian
    Biskos, George
    [J]. AEROSOL SCIENCE AND TECHNOLOGY, 2018, 52 (04) : 385 - 392
  • [6] How to Get the Best from Low-Cost Particulate Matter Sensors: Guidelines and Practical Recommendations
    Brattich, Erika
    Bracci, Alessandro
    Zappi, Alessandro
    Morozzi, Pietro
    Di Sabatino, Silvana
    Porcu, Federico
    Di Nicola, Francesca
    Tositti, Laura
    [J]. SENSORS, 2020, 20 (11) : 1 - 33
  • [7] Laboratory Comparison of Low-Cost Particulate Matter Sensors to Measure Transient Events of Pollution
    Bulot, Florentin Michel Jacques
    Russell, Hugo Savill
    Rezaei, Mohsen
    Johnson, Matthew Stanley
    Ossont, Steven James Johnston
    Morris, Andrew Kevin Richard
    Basford, Philip James
    Easton, Natasha Hazel Celeste
    Foster, Gavin Lee
    Loxham, Matthew
    Cox, Simon James
    [J]. SENSORS, 2020, 20 (08)
  • [8] Evolution of PM2.5 Measurements and Standards in the US and Future Perspectives for China
    Cao, Junji
    Chow, Judith C.
    Lee, Frank S. C.
    Watson, John G.
    [J]. AEROSOL AND AIR QUALITY RESEARCH, 2013, 13 (04) : 1197 - 1211
  • [9] Comparison of real-time instruments used to monitor airborne particulate matter
    Chung, A
    Chang, DPY
    Kleeman, MJ
    Perry, KD
    Cahill, TA
    Dutcher, D
    McDougall, EM
    Stroud, K
    [J]. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2001, 51 (01) : 109 - 120
  • [10] Particle resuspension during the use of vacuum cleaners on residential carpet
    Corsi, Richard L.
    Siegel, Jeffrey A.
    Chiang, Chunyi
    [J]. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2008, 5 (04) : 232 - 238