High-precision half-life measurement of 123Xe and 125Xe for fuel areal density diagnosing in inertial confinement fusion

被引:3
作者
Zeng Jun [1 ]
Zhang Yingzeng [1 ]
Gong Youjin [1 ]
Luo Fei [1 ]
Xiang Qingpei [1 ]
Xiang Yongchun [1 ]
Hao Fanhua [1 ]
机构
[1] China Acad Engn Phys, Inst Nucl Phys & Chem, Mianyang 621900, Sichuan, Peoples R China
基金
中国国家自然科学基金;
关键词
Xe-123; Xe-125; Half-life; Reference source method; ICF; NUCLEAR-DATA SHEETS;
D O I
10.1016/j.apradiso.2020.109511
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
The half-lives of Xe-123 and Xe-125 are important to diagnose deuterium-tritium (DT) fuel areal density in inertial confinement fusion (ICF). In this work, those two half-lives have been measured with HPGe gamma-ray spectrometers using the reference source method. Data have been recorded over seven half-lives with three independent measurements for Xe-123 and two for Xe-125. New values of Xe-123 (2.040 +/- 0.009) h and Xe-125 (17.048 +/- 0.032) h have been determined with significant reduction of the uncertainty compared to the currently recommended value of (2.08 +/- 0.02) and (16.9 +/- 0.2) h, respectively.
引用
收藏
页数:7
相关论文
共 27 条
[1]   RADIOACTIVE XENON-125, AND XENON-127 [J].
ANDERSON, DL ;
POOL, ML .
PHYSICAL REVIEW, 1950, 77 (01) :142-142
[2]  
ANDERSSON G, 1965, ARK FYS, V28, P37
[3]  
AUBLE RL, 1972, NUCL DATA SHEETS B, V7, P363
[4]  
AUBLE RL, 1972, NUCLEAR DATA B, V7, P465
[5]  
BERGSTROM I, 1952, ARK FYS, V5, P191
[6]   Comprehensive sets of 124Xe(n, γ)125Xe and 124Xe(n, 2n)123Xe cross-section data for assessment of inertial-confinement deuterium-tritium fusion plasma [J].
Bhike, Megha ;
Fallin, B. ;
Gooden, M. E. ;
Ludin, N. ;
Tornow, W. .
PHYSICAL REVIEW C, 2015, 91 (01)
[7]  
Burmistrov V. R., 1969, Yadernaya Fizika, V9, P673
[8]   RADIOISOTOPES OF IODINE AND XENON OF MASSES 120 AND 121 [J].
BUTEMENT, FD ;
QAIM, SM .
JOURNAL OF INORGANIC & NUCLEAR CHEMISTRY, 1965, 27 (05) :907-&
[9]  
Dauria J.M., 1966, THESIS, P310
[10]   Prompt radiochemistry at the National Ignition Facility (invited) [J].
Grim, G. P. ;
Bradley, P. A. ;
Bredeweg, T. A. ;
Keksis, A. L. ;
Fowler, M. M. ;
Hayes, A. C. ;
Jungman, G. ;
Obst, A. W. ;
Rundberg, R. S. ;
Vieira, D. J. ;
Wilhelmy, J. B. ;
Bernstein, L. A. ;
Cerjan, C. J. ;
Fortner, R. J. ;
Moody, K. J. ;
Schneider, D. H. ;
Shaughnessy, D. A. ;
Stoeffl, W. ;
Stoyer, M. A. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (10)