Gadoxate-Enhanced T1-Weighted MR Cholangiography: Comparison of 1.5T and 3.0T

被引:15
作者
Koelblinger, C. [1 ]
Schima, W. [1 ]
Weber, M. [1 ]
Mang, T. [1 ]
Nemec, S. [1 ]
Kulinna-Cosentini, C. [1 ]
Bastati, N. [1 ]
Ba-Ssalamah, A. [1 ]
机构
[1] Med Univ Wien, Univ Klin Radiodiagnost, A-1090 Vienna, Austria
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2009年 / 181卷 / 06期
关键词
biliary system; MR cholangiography; Gadoxate; T1; 3.0T; field strength; GD-EOB-DTPA; MAGNETIC-RESONANCE CHOLANGIOGRAPHY; CLINICAL-APPLICATIONS; BILIARY ANATOMY; CONTRAST AGENT; IN-VIVO; LIVER; CHOLANGIOPANCREATOGRAPHY; EXPERIENCE; 3.0-TESLA;
D O I
10.1055/s-0028-1109141
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To qualitatively and quantitatively compare gadoxate-enhanced T1-weighted MR cholangiography at magnetic field strengths of 1.5T and 3.0T. Materials and Methods: A total of 40 patients with a non-dilated biliary system were retrospectively included in the Study. T1-weighted MR cholangiography 20min after IV administration of 0.025 mmol/kg gadoxate (Primovist (TM)) was performed in 20 patients at 1.5T and in another 20 patients at 3.0T. Contrast-to-noise ratios (CNR) of the biliary system (common bile duct - CBD, right hepatic duct - RHD, left hepatic duct LHD) compared to the periductal tissue were measured. Two radiologists also qualitatively assessed the visibility of the intrahepatic and extrahepatic biliary system using a six-point rating scale. The Mann-Whitney U-test and Pearson's correlation coefficient were used for statistical analysis. Results: The CINRs of the intrahepatic and extrahepatic hepatic bile ducts were significantly higher at 3.0T. Qualitative analysis showed a significant superiority for 3.0T in the delineation of the intrahepatic biliary system (RHD, LHD, segmental ducts). Conclusion: Gadoxate-enhanced T1-w MR cholangiography at 3.0T offers better delineation of the intrahepatic biliary system in comparison to imaging at 1.5T.
引用
收藏
页码:587 / 592
页数:6
相关论文
共 50 条
  • [21] CEMRA in neonatal and pediatric congenital vascular diseases at 1.5T and 3.0T: comparison of an intravascular contrast agent (Gadofosveset) with an extracellular agent (Gadopentetate Dimeglumine)
    Sarah N Khan
    Carlos DaSilva
    J Paul Finn
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [22] CEMRA in neonatal and pediatric congenital vascular diseases at 1.5T and 3.0T: comparison of an intravascular contrast agent (Gadofosveset) with an extracellular agent (Gadopentetate Dimeglumine)
    SN Khan
    C DaSilva
    P Renella
    G Satou
    I Ayad
    S Patel
    I Boechat
    P Finn
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [23] 3D T2-weighted and Gd-EOB-DTPA-enhanced 3D T1-weighted MR cholangiography for evaluation of biliary anatomy in living liver donors
    Cai, Larry
    Yeh, Benjamin M.
    Westphalen, Antonio C.
    Roberts, John
    Wang, Zhen J.
    ABDOMINAL RADIOLOGY, 2017, 42 (03) : 842 - 850
  • [24] 3D T2-weighted and Gd-EOB-DTPA-enhanced 3D T1-weighted MR cholangiography for evaluation of biliary anatomy in living liver donors
    Larry Cai
    Benjamin M. Yeh
    Antonio C. Westphalen
    John Roberts
    Zhen J. Wang
    Abdominal Radiology, 2017, 42 : 842 - 850
  • [25] Diagnosis of biliary stone disease: T1-weighted magnetic resonance cholangiography with Gd-EOB-DTPA versus T2-weighted magnetic resonance cholangiography
    Choi, In Young
    Yeom, Suk Keu
    Cha, Sang Hoon
    Lee, Seung Hwa
    Chung, Hwan Hoon
    Hyun, Jong Jin
    Kim, Baek Hyun
    CLINICAL IMAGING, 2014, 38 (02) : 164 - 169
  • [26] T1-WEIGHTED SEQUENCES FOR MR IMAGING OF THE LIVER - COMPARISON OF 3 TECHNIQUES FOR SINGLE-BREATH, WHOLE-VOLUME ACQUISITION AT 1.0-T AND 1.5-T
    SEMELKA, RC
    SIMM, FC
    RECHT, M
    DEIMLING, M
    LENZ, G
    LAUB, GA
    RADIOLOGY, 1991, 180 (03) : 629 - 635
  • [27] COMPARISON OF BREATH-HOLD T1-WEIGHTED MR SEQUENCES FOR IMAGING OF THE LIVER
    SEMELKA, RC
    WILLMS, AB
    BROWN, MA
    BROWN, ED
    FINN, JP
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (06): : 759 - 765
  • [28] Comparison of dynamic contrast-enhanced MRI parameters of breast lesions at 1.5 and 3.0T: a pilot study
    Pineda, F. D.
    Medved, M.
    Fan, X.
    Ivancevic, M. K.
    Abe, H.
    Shimauchi, A.
    Newstead, G. M.
    Karczmar, G. S.
    BRITISH JOURNAL OF RADIOLOGY, 2015, 88 (1049)
  • [29] Enhancement Effects of Hepatic Dynamic MR Imaging at 3.0 T and 1.5 T Using Gadoxetic Acid in a Phantom Study: Comparison with Gadopentetate Dimeglumine
    Morita, Kosuke
    Namimoto, Tomohiro
    Awai, Kazuo
    Komi, Masanori
    Hashida, Masahiro
    Tsuji, Takashi
    Hirai, Toshinori
    Yamashita, Yasuyuki
    MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (01) : 213 - 218
  • [30] Added value of gadoxetic acid-enhanced T1-weighted magnetic resonance cholangiography for the diagnosis of post-transplant biliary complications
    Kinner, Sonja
    Schubert, Tilman B.
    Said, Adnan
    Mezrich, Joshua D.
    Reeder, Scott B.
    EUROPEAN RADIOLOGY, 2017, 27 (10) : 4415 - 4425