Thermal Performance Modeling of Hybrid Liquid-Air Cooled Servers

被引:0
|
作者
Zeighami, Roy [1 ]
Coles, Henry [2 ]
Saunders, Winston A. [3 ]
Branton, Steve [4 ]
机构
[1] Cisco Corp, Richardson, TX 75082 USA
[2] Lawrence Berkeley Labs, Berkeley, CA 94720 USA
[3] Intel Corp, Hillsboro, OR 97124 USA
[4] Asetek Inc, San Jose, CA 95138 USA
关键词
server; data center; liquid; air; cooling; power; energy reuse; water cooling;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper discusses data center scale performance characterization of hybrid liquid-air cooling solutions for a full 42U rack of servers. Using data collected in a production data center at Lawrence Berkeley Laboratories, we interpret the results with a simple three parameter model which allows characterization of the major factors affecting heat recovery efficiency of the system. The model is shown to agree with a broad set of data under a variety of temperature and workload conditions. To our knowledge, this is the first large scale characterization of a hybrid cooling solution's performance in terms relevant to data center operation. We discuss how this method can be extended to other systems for meaningful comparison of solution performance.
引用
收藏
页码:583 / 587
页数:5
相关论文
共 50 条
  • [41] Formation of iron containing aggregates at the liquid-air interface
    Wieland, D. C. Florian
    Degen, Patrick
    Paulus, Michael
    Schroer, Martin A.
    Bieder, Steffen
    Sahle, Christoph J.
    Moeller, Johannes
    Leick, Sabine
    Chen, Zhao
    Struth, Bernd
    Rehage, Heinz
    Tolan, Metin
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2013, 109 : 74 - 81
  • [42] Performance Enhancement of Single-Phase Immersion Liquid-Cooled Data Center Servers
    GE Junlei
    XIA Feifan
    ZHANG Chengbin
    HUANG Yongping
    JournalofThermalScience, 2024, 33 (05) : 1757 - 1772
  • [43] GLASS-FIBER INSULATION AT LIQUID-AIR TEMPERATURES
    PALMER, BM
    TAYLOR, RB
    CHEMICAL ENGINEERING PROGRESS, 1948, 44 (08) : 652 - 654
  • [44] Spontaneous MXene monolayer assembly at the liquid-air interface
    Petukhov, D. I.
    Chumakov, A. P.
    Kan, A. S.
    Lebedev, V. A.
    Eliseev, Artem A.
    Konovalov, O. V.
    Eliseev, Andrei A.
    NANOSCALE, 2019, 11 (20) : 9980 - 9986
  • [45] CHANGE OF RESISTIVITY BY COLD WORKING AT LIQUID-AIR TEMPERATURE
    MOLENAAR, J
    AARTS, WH
    NATURE, 1950, 166 (4225) : 690 - 690
  • [46] Phase Segregation at the Liquid-Air Interface Prior to Liquid-Liquid Equilibrium
    Bermudez-Salguero, Carolina
    Gracia-Fadrique, Jesus
    JOURNAL OF PHYSICAL CHEMISTRY B, 2015, 119 (32): : 10304 - 10315
  • [47] COMPARISON OF LIQUID AND AIR COOLED GARMENTS FOR ALLEVIATING THERMAL-STRESS
    WISSLER, EH
    NUNNELEY, SA
    AVIATION SPACE AND ENVIRONMENTAL MEDICINE, 1985, 56 (05): : 501 - 501
  • [48] Thermal Modeling and Experimental Verification of an Air Cooled Medium Frequency Transformer
    Mogorovic, Marko
    Dujic, Drazcn
    2017 19TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE'17 ECCE EUROPE), 2017,
  • [49] Electroosmosis near surfactant laden liquid-air interfaces
    Blanc, Baptiste
    Bonhomme, Oriane
    Brevet, Pierre-Francois
    Benichou, Emmanuel
    Ybert, Christophe
    Biance, Anne-Laure
    SOFT MATTER, 2018, 14 (14) : 2604 - 2609
  • [50] The decomposition of methane in glow discharge at liquid-air temperature
    Yeddanapalli, LM
    JOURNAL OF CHEMICAL PHYSICS, 1942, 10 (05): : 249 - 260