In Vitro Three-Dimensional Accuracy of Digital Implant Impressions: The Effect of Implant Angulation

被引:62
作者
Chia, Vanessa A. [1 ]
Esguerra, Roxanna J. [2 ]
Teoh, Khim Hean [1 ]
Teo, Juin Wei [3 ]
Wong, Keng Mun [2 ]
Tan, Keson B. [2 ]
机构
[1] Natl Dent Ctr Singapore, Dept Restorat Dent, Singapore, Singapore
[2] Natl Univ Singapore, Fac Dent, 11 Lower Kent Ridge Rd, Singapore 119083, Singapore
[3] Khoo Teck Puat Hosp, Dept Dent, Singapore, Singapore
关键词
accuracy; coordinate measuring machine; digital; implant impression; scan body; three-dimensional; DEFINITIVE CASTS; CONNECTION; PROSTHESES; SYSTEMS; FIT; COMPONENTS; PRECISION; PARALLEL; DEPTH;
D O I
10.11607/jomi.5087
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To compare the three-dimensional (3D) accuracy of conventional impressions (CIs) with digital scans (DSs) using an intraoral scanner (IOS) with intraoral scan bodies (SBs) and varying buccolingual interimplant angulations. A secondary aim was to measure the SB machining tolerance and height with and without application of torque. Materials and Methods: Three master models (MMs) with two implants simulating an implant-supported three-unit fixed partial denture for bone-level implants were used. The implants had buccolingual interimplant angulations of 0, 10, and 20 degrees. Test models for the CI test groups were made with impression copings and polyether impressions. SBs were attached to the MMs, tightened to 15-Ncm torque, and scanned by an IOS for the DS test groups (six test groups, n = 5). A coordinate measuring machine measured linear distortions (dx, dy, dz), 3D distortions (dR), angular distortions (d.x, d.y), and absolute angular distortions (Absd.x, Absd.y) of the physical CI test models and STL files of the DS virtual models relative to the MMs. Metrology software allowed both physical and virtual measurement of geometric targets that were comparable and allowed computation of relative displacements of implant centroids and axes. Results: Mean dR ranged from 31 +/- 14.2 to 45 +/- 3.4 mu m for DS and 18 +/- 8.4 to 36 +/- 6.5 mu m for the CI test groups. Mean Absd.x ranged from 0.041 +/- 0.0318 to 0.794 +/- 0.2739 degrees for DS and 0.073 +/- 0.0618 to 0.545 +/- 0.0615 degrees for the CI test groups. Mean Absd.y ranged from 0.075 +/- 0.0615 to 0.111 +/- 0.0639 degrees for DS and 0.106 +/- 0.0773 to 0.195 +/- 0.1317 degrees for the CI test groups. Two-way analysis of variance showed that the impression technique (P = .012) and implant angulations (P = .007) had a significant effect on dR. Distortions were mostly in the negative direction for DS test groups. Perfect coaxiality of the SB with the implant was never achieved. For SB to implant machining tolerances, the mean absolute horizontal displacement ranged from 4 +/- 1.2 to 7 +/- 2.3 mu m. The SB dz was -5 +/- 3.2 mu m, which increased in the negative direction to -11 +/- 4.9 mu m with torque application (P = .002). Conclusion: Distortions were found for both DS and CI test groups. The best accuracy was obtained with CIs for parallel implants. With angulated implants, conventional and DSs were not significantly different. Excessive torque application that causes negative dz for SB fit would position the virtual implant at a deeper location compared with reality, resulting in possible framework misfit.
引用
收藏
页码:313 / 321
页数:9
相关论文
共 36 条
  • [11] Gallucci GO, 2011, INT J PROSTHODONT, V24, P469
  • [12] Accuracy of Two Digital Implant Impression Systems Based on Confocal Microscopy with Variations in Customized Software and Clinical Parameters
    Gimenez, Beatriz
    Pradies, Guillermo
    Martinez-Rus, Francisco
    Oezcan, Mutlu
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2015, 30 (01) : 56 - 64
  • [13] Accuracy of a Digital Impression System Based on Parallel Confocal Laser Technology for Implants with Consideration of Operator Experience and Implant Angulation and Depth
    Gimenez, Beatriz
    Oezcan, Mutlu
    Martinez-Rus, Francisco
    Pradies, Guillermo
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (04) : 853 - 862
  • [14] Accuracy of a Digital Impression System Based on Active Wavefront Sampling Technology for Implants Considering Operator Experience, Implant Angulation, and Depth
    Gimenez, Beatriz
    Oezcan, Mutlu
    Martinez-Rus, Francisco
    Pradies, Guillermo
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2015, 17 : E54 - E64
  • [15] EVALUATION OF 3 IMPRESSION TECHNIQUES FOR OSSEOINTEGRATED ORAL IMPLANTS
    INTURREGUI, JA
    AQUILINO, SA
    RYTHER, JS
    LUND, PS
    SOUTHARD, TE
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1993, 69 (05) : 503 - 509
  • [16] Kim S, 2006, INT J ORAL MAX IMPL, V21, P747
  • [17] THE ACCURACY OF IMPLANT IMPRESSIONS: A SYSTEMATIC REVIEW
    Lee, Heeje
    So, Joseph S.
    Hochstedler, J. L.
    Ercoli, Carlo
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2008, 100 (04) : 285 - 291
  • [18] Effect of subgingival depth of implant placement on the dimensional accuracy of the implant impression: An in vitro study
    Lee, Heeje
    Ercoli, Carlo
    Funkenbusch, Paul D.
    Feng, Changyong
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2008, 99 (02) : 107 - 113
  • [19] Axial displacements in external and internal implant-abutment connection
    Lee, Ji-Hye
    Kim, Dae-Gon
    Park, Chan-Jin
    Cho, Lee-Ra
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (02) : E83 - E89
  • [20] Effect of Implant Divergence on the Accuracy of Definitive Casts Created from Traditional and Digital Implant-Level Impressions: An In Vitro Comparative Study
    Lin, Wei-Shao
    Harris, Bryan T.
    Elathamna, Eiad N.
    Abdel-Azim, Tamer
    Morton, Dean
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2015, 30 (01) : 102 - 109