共 24 条
Optical Detection of Acetone Using ?Turn-Off? Fluorescent RiceStraw Based Cellulose Carbon Dots Imprinted onto Paper Dipstickfor Diabetes Monitoring
被引:11
作者:
Alshareef, Mubark
[1
]
Snari, Razan M.
[1
]
Alaysuy, Omaymah
[2
]
Aldawsari, Afrah M.
[1
,3
]
Abumelha, Hana M.
[4
]
Katouah, Hanadi
[1
]
El-Metwaly, Nashwa M.
[1
,5
]
机构:
[1] Umm Al Qura Univ, Fac Appl Sci, Dept Chem, Mecca 24230, Saudi Arabia
[2] Univ Tabuk, Coll Sci, Dept Chem, Tabuk 71474, Saudi Arabia
[3] King Abdulaziz City Sci & Technol, Riyadh 11442, Saudi Arabia
[4] Princess Nourah Bint Abdulrahman Univ, Coll Sci, Dept Chem, Riyadh 11671, Saudi Arabia
[5] Mansoura Univ, Fac Sci, Dept Chem, Mansoura 35516, Egypt
来源:
ACS OMEGA
|
2022年
/
7卷
/
19期
关键词:
GRAPHENE QUANTUM DOTS;
SELECTIVE DETECTION;
GAS SENSOR;
HYDROTHERMAL SYNTHESIS;
SENSING PROPERTIES;
MICROFLUIDIC CHIP;
BREATH ANALYSIS;
DIAGNOSIS;
ION;
WO3;
D O I:
10.1021/acsomega.2c01492
中图分类号:
O6 [化学];
学科分类号:
0703 ;
摘要:
Persistent bad breath has been reported as a sign of serious diabetes health conditions. If an individual's breath has astrong odor of acetone, it may indicate high levels of ketones in the blood owing to diabetic ketoacidosis. Thus, acetone gas in thebreath of patients with diabetes can be detected using the current easy-to-usefluorescent test dipstick. In another vein, rice strawwaste is the most well-known solid pollutant worldwide. Thus,finding a simple technique to change rice straw into a valuablematerial is highly important. A straightforward and environmentally friendly approach for reprocessing rice straw as a startingmaterial for the creation offluorescent nitrogen-doped carbon dots (NCDs) has been established. The preparation process of NCDswas carried out via one-pot hydrothermal carbonization using NH4OH as a passivation substance. A testing strip was developed onthe basis of cellulose CD nanoparticles (NPs) immobilized onto cellulose paper assay. The NCDs demonstrated a quantum yield of23.76%. Afluorescence wavelength was detected at 443 nm upon applying an excitation wavelength of 354 nm. NCDs demonstratedremarkable selectivity for acetone gas as theirfluorescence was definitely exposed to quenching by acetone as a consequence of theinnerfilter effect. A linear correlation was observed across the concentration range of 0.5-150 mM. To detect and measure acetonegas, the present cellulose paper strip has a"switch off"fluorescent signal. A readout limit was accomplished for an aqueous solutionof acetone as low as 0.5 mM under ambient conditions. The chromogenicfluorescence of the cellulose assay responsiveness dependson thefluorescence quenching characteristic of the cellulose carbon dots in acetone. A thinfluorescent cellulose carbon dot layer wasdeposited onto the surface of cellulose strips by a simple impregnation process. CDs were made using NP morphology and analyzedusing infrared spectroscopy and transmission electron microscopy. The carbon dot distribution on the paper strip was evaluated byscanning electron microscope and energy-dispersive X-ray analysis. The absorption andfluorescence spectral analyses wereinvestigated. The paper sheets'mechanical qualities were also examined.
引用
收藏
页码:16766 / 16777
页数:12
相关论文