Total hip replacement with a collarless polished cemented anatomic stem: clinical and gait analysis results at ten years follow-up

被引:4
|
作者
Grzesiak, Arthur [1 ,2 ,5 ]
Aminian, Kamiar [3 ]
Lecureux, Estelle [2 ,4 ,5 ]
Jobin, Florence [1 ,2 ,6 ]
Jolles, Brigitte M. [1 ,2 ,6 ]
机构
[1] CHU Vaudois, Dept Orthopaed Surg & Traumatol, CH-1011 Lausanne, Switzerland
[2] Univ Lausanne, Lausanne, Switzerland
[3] Ecole Polytech Fed Lausanne, Interinst Ctr Translat Biomech, Lab Movement Anal & Measurement, CH-1015 Lausanne, Switzerland
[4] CHU Vaudois, Dept Musculoskeletal Med, CH-1011 Lausanne, Switzerland
[5] CHU Vaudois, CH-1011 Lausanne, Switzerland
[6] CHU Vaudois, Site Hop Orthoped, CH-1011 Lausanne, Switzerland
关键词
Total hip replacement; Cemented stem; Anatomic femoral stem; Gait analysis; Outcome; Geriatric population; FEMORAL COMPONENT; ARTHROPLASTY; OSTEOARTHRITIS;
D O I
10.1007/s00264-013-2186-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The aim of this study was to determine outcomes of total hip replacement (THR) with the Lemania cemented femoral stem. A total of 78 THR patients were followed and compared to 17 "fit", healthy, elderly and 72 "frail" elderly subjects without THR, using clinical outcome measures and a portable, in-field gait analysis device at five and ten years follow-up. Forty-one patients (53 %), mean age 83.4 years, available at ten years follow-up, reported very good to excellent satisfaction. Mean Harris Hip and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) scores were 81.2 and 10.5 points, respectively, with excellent radiological preservation of proximal femur bone stock. Spatial and temporal gait parameters were close to the fit group and better than the frail group. Lemania THR demonstrated very good, stable clinical and radiological results at ten years in an older patient group, comparable to other cemented systems for primary THR. Gait analysis confirmed good walking performance in a real-life environment.
引用
收藏
页码:717 / 724
页数:8
相关论文
共 50 条
  • [31] Gait kinetics of total hip replacement patients A large scale, long-term follow-up study
    Bennett, Damien
    Ryan, Paul
    O'Brien, Seamus
    Beverland, David E.
    GAIT & POSTURE, 2017, 53 : 173 - 178
  • [32] Automatic Tools for Diagnosis Support of Total Hip Replacement Follow-up
    Florea, Laura
    Florea, Corneliu
    Vertan, Constantin
    Sultana, Alina
    ADVANCES IN ELECTRICAL AND COMPUTER ENGINEERING, 2011, 11 (04) : 55 - 62
  • [33] Gait Analysis of Leg Length Discrepancy-Differentiated Hip Replacement Patients With Developmental Dysplasia: A Midterm Follow-Up
    Chen, Guo
    Nie, Yong
    Xie, Jinwei
    Cao, Guorui
    Huang, Qiang
    Pei, Fuxing
    JOURNAL OF ARTHROPLASTY, 2018, 33 (05) : 1437 - 1441
  • [34] Cementless total hip arthroplasty for osteonecrosis and osteoarthritis produce similar results at ten years follow-up when matched for age and gender
    Osawa, Yusuke
    Seki, Taisuke
    Takegami, Yasuhiko
    Kusano, Taiki
    Makida, Kazuya
    Ishiguro, Naoki
    INTERNATIONAL ORTHOPAEDICS, 2018, 42 (07) : 1683 - 1688
  • [35] Excellent mid-term results of a new polished tapered modular cemented stem: a study of 113 hip replacements with minimum 5-year follow-up
    Vanbiervliet, Jens
    Somers, Jan F. A.
    HIP INTERNATIONAL, 2017, 27 (05) : 455 - 459
  • [36] Computer-based gait analysis of dogs: Evaluation of kinetic and kinematic parameters after cemented and cementless total hip replacement
    Drueen, S.
    Boeddeker, J.
    Meyer-Lindenberg, A.
    Fehr, M.
    Nolte, I.
    Wefstaedt, P.
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2012, 25 (05) : 375 - 384
  • [37] Five-year prospective subsidence analysis of 100 cemented polished straight stems: A concise clinical and radiological follow-up observation
    Madoerin, Kevin
    Siepen, Wolf
    Manzoni, Isabella
    Stoffel, Karl Kilian
    Hchmann, Thomas
    Clauss, Martin
    ORTHOPEDIC REVIEWS, 2019, 11 (02) : 56 - 62
  • [38] Early results of Latitude primary total elbow replacement with a minimum follow-up of 2 years
    Mehta, Saurabh S.
    Watts, Adam C.
    Talwalkar, Sumedh C.
    Birch, Ann
    Nuttall, David
    Trail, Ian A.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2017, 26 (10) : 1867 - 1872
  • [39] Minimum 5 year follow-up of clinical and radiographic results of cemented acetabular components with an interface bioactive bone cement technique in primary cemented total hip arthroplasty
    Miyamoto, Shuichi
    Iida, Satoshi
    Suzuki, Chiho
    Nakatani, Takushi
    Kawarai, Yuya
    Nakamura, Junichi
    Orita, Sumihisa
    Ohtori, Seiji
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2021, 141 (01) : 139 - 147
  • [40] Clinical and radiological outcome at 10 years of follow-up after total cervical disc replacement
    Mehren, Christoph
    Heider, Franziska
    Siepe, Christoph J.
    Zillner, Bernhard
    Kothe, Ralph
    Korge, Andreas
    Mayer, H. Michael
    EUROPEAN SPINE JOURNAL, 2017, 26 (09) : 2441 - 2449