FiberWire vs FiberTape: Comparison of Bacterial Adherence in a Murine Air Pouch Wound Model

被引:4
作者
Blumenthal, Allison M. [1 ,2 ]
Bou-akl, Therese [1 ,2 ]
Rossi, Mario D. [1 ,2 ]
Wu, Bin [1 ,2 ]
Ren, Wei-Ping [1 ,3 ]
Markel, David C. [1 ,2 ]
机构
[1] Ascens Providence Southfield Hosp, Southfield, MI USA
[2] Ascens Providence Hlth Syst, Southfield, MI USA
[3] Wayne State Univ, Detroit, MI USA
关键词
FiberWire; FiberTape; suture; bacterial adherence; murine; BIOFILM FORMATION; SUTURE MATERIAL; STRENGTH; TAPE; MONOFILAMENT;
D O I
10.1177/2325967120964480
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: For high-tensile strength sutures, past research has largely focused on mechanical properties or bacterial adherence across various manufacturers. Purpose: This study investigated high-tensile strength sutures with different shapes but otherwise identical composition. The purpose was to evaluate the differences between high-tensile strength suture wire and suture tape relative to bacterial adherence and bacterial retention after washout. Study Design: Controlled laboratory study. Methods: Sutures were implanted in dorsal air pouches of 72 BALB/cJ mice. Experimental pouches were inoculated with Staphylococcus aureus; no bacteria were used in the control conditions. The mice were randomized into 3 groups: group 1 underwent suture extraction 7 days after implantation; group 2 underwent an irrigation procedure, followed by immediate suture extraction on day 7; and group 3 underwent an irrigation procedure on day 7, with delayed suture extraction on day 14 after implantation. The sutures were evaluated using confocal microscopy; electron microscopy; and spectrophotometry, through which optical density, as measured by the amount of scattered light, is directly correlated with the number of bacteria. Histological assessment was performed on the pouches. Results: Optical density (mean +/- SD) was significantly higher for FiberTape sutures than for FiberWire sutures, respectively, at the 2-hour time point for all groups (group 1, 0.0550 +/- 0.0081 vs 0.0162 +/- 0.006 [P = .0054]; group 2, 0.0225 +/- 0.0049 vs 0.0056 +/- 0.0006 [P = .0045]; group 3, 0.055 +/- 0.0222 vs 0.0043 +/- 0.0005 [P = .0103]). Additionally, groups 2 and 3 showed statistically significant results at the 4-hour time points (group 2, 0.0384 +/- 0.0087 vs 0.0145 +/- 0.0042 [P = .0280]; group 3, 0.0532 +/- 0.0159 vs 0.0101 +/- 0.0025 [P = .0058]). The wash fluid also demonstrated significantly greater optical density for the FiberTape than the FiberWire sutures, respectively, at the 2-hour time point for all groups (group 1, 0.1657 +/- 0.0319 vs 0.0317 +/- 0.008 [P = .0063]; group 2, 0.0522 +/- 0.0156 vs 0.0127 +/- 0.0022 [P = .0219]; group 3, 0.1707 +/- 0.0205 vs 0.0191 +/- 0.0053 [P < .0001]). No bacterial growth occurred in the control conditions. Histological assessment revealed only mild inflammation in the control groups as compared with more severe responses in the experimental groups at all time points. Conclusion: FiberTape was associated with increased bacterial adhesion as well as retention as compared with FiberWire in an in vivo murine wound model.
引用
收藏
页数:8
相关论文
共 15 条
  • [1] Influence of suture material on the biomechanical behavior of suture-tendon specimens - A controlled study in bovine rotator cuff
    Bisson, Leslie J.
    Manohar, Leslie M.
    Wilkins, Ryan D.
    Gurske-Deperio, Jennifer
    Ehrensberger, Mark T.
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2008, 36 (05) : 907 - 912
  • [2] A Biomechanical Comparison of the Pullout Strength of No. 2 FiberWire Suture and 2-mm FiberWire Tape in Bovine Rotator Cuff Tendons
    Bisson, Leslie J.
    Manohar, Leslie M.
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2010, 26 (11) : 1463 - 1468
  • [3] In Vitro Biomechanical Evaluation and Comparison of FiberWire, FiberTape, OrthoFiber, and Nylon Leader Line for Potential Use During Extraarticular Stabilization Of Canine Cruciate Deficient Stifles
    Burgess, Richard
    Elder, Steve
    McLaughlin, Ron
    Constable, Peter
    [J]. VETERINARY SURGERY, 2010, 39 (02) : 208 - 215
  • [4] Carr Brian J, 2009, Orthopedics, V32, P828, DOI 10.3928/01477447-20090922-11
  • [5] Abrasive Properties of Braided Polyblend Sutures in Cuff Tendon Repair: An in Vitro Biomechanical Study Exploring Regular and Tape Sutures
    Deranlot, Julien
    Maurel, Nathalie
    Diop, Amadou
    Pratlong, Nathalie
    Roche, Lucas
    Tiemtore, Roch
    Nourissat, Geoffroy
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2014, 30 (12) : 1569 - 1573
  • [6] Bacterial Adhesion to Suture Material in a Contaminated Wound Model: Comparison of Monofilament, Braided, and Barbed Sutures
    Dhom, Jonas
    Bloes, Dominik A.
    Peschel, Andreas
    Hofmann, Ulf K.
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2017, 35 (04) : 925 - 933
  • [7] PHYSICAL AND CHEMICAL CONFIGURATION OF SUTURES IN DEVELOPMENT OF SURGICAL INFECTION
    EDLICH, RF
    PANEK, PH
    RODEHEAVER, GT
    TURNBULL, VG
    KURTZ, LD
    EDGERTON, MT
    [J]. ANNALS OF SURGERY, 1973, 177 (06) : 679 - 688
  • [8] Evaluation of soft tissue reactions to three nonabsorbable suture materials in a rabbit model
    Esenyel, Cem Zeki
    Demirhan, Mehmet
    Kilicoglu, Onder
    Adanir, Oktay
    Bilgic, Bilge
    Guzel, Ozlem
    Ozsoy, Serhat
    [J]. ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2009, 43 (04) : 366 - 372
  • [9] High-Tensile Strength Tape Versus High-Tensile Strength Suture: A Biomechanical Study
    Gnandt, Ryan J.
    Smith, Jennifer L.
    Nguyen-Ta, Kim
    McDonald, Lucas
    LeClere, Lance E.
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2016, 32 (02) : 356 - 363
  • [10] Security of Knots Tied With Ethibond, Fiberwire, Orthocord, or Ultrabraid
    Ilahi, Omer A.
    Younas, Shiraz A.
    Ho, David M.
    Noble, Phillip C.
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2008, 36 (12) : 2407 - 2414