Integration of independent component analysis with near-infrared spectroscopy for analysis of bioactive components in the medicinal plant Gentiana scabra Bunge

被引:21
作者
Chuang, Yung-Kun [1 ,2 ]
Yang, I-Chang [2 ]
Lo, Yangming Martin [2 ]
Tsai, Chao-Yin [3 ]
Chen, Suming [1 ,3 ]
机构
[1] Natl Taiwan Univ, Dept Bioind Mechatron Engn, Taipei 10617, Taiwan
[2] Univ Maryland, Dept Nutr & Food Sci, College Pk, MD 20742 USA
[3] Natl Taiwan Univ, Bioenergy Res Ctr, Taipei 10617, Taiwan
关键词
Gentiana scabra Bunge; Gentiopicroside; Independent component analysis; Near-infrared spectroscopy; Swertiamarin; SECOIRIDOID GLYCOSIDES; GENTIOPICROSIDE; NIR; CONSTITUENTS; PREDICTION; LUTEA;
D O I
10.1016/j.jfda.2014.01.021
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Independent component (IC) analysis was applied to near-infrared spectroscopy for analysis of gentiopicroside and swertiamarin; the two bioactive components of Gentiana scabra Bunge. ICs that are highly correlated with the two bioactive components were selected for the analysis of tissue cultures, shoots and roots, which were found to distribute in three different positions within the domain [two-dimensional (2D) and 3D] constructed by the ICs. This setup could be used for quantitative determination of respective contents of gentiopicroside and swertiamarin within the plants. For gentiopicroside, the spectral calibration model based on the second derivative spectra produced the best effect in the wavelength ranges of 600-700 nm, 1600-1700 nm, and 2000-2300 nm (correlation coefficient of calibration = 0.847, standard error of calibration = 0.865%, and standard error of validation = 0.909%). For swertiamarin, a spectral calibration model based on the first derivative spectra produced the best effect in the wavelength ranges of 600-800 nm and 2200-2300 nm (correlation coefficient of calibration = 0.948, standard error of calibration = 0.168%, and standard error of validation = 0.216%). Both models showed a satisfactory predictability. This study successfully established qualitative and quantitative correlations for gentiopicroside and swertiamarin with near-infrared spectra, enabling rapid and accurate inspection on the bioactive components of G. scabra Bunge at different growth stages. Copyright (C) 2014, Food and Drug Administration, Taiwan. Published by Elsevier Taiwan LLC. All rights reserved.
引用
收藏
页码:336 / 344
页数:9
相关论文
共 22 条
[1]   Analysis of iridoids, secoiridoids and xanthones in Centaurium erythraea, Frasera caroliniensis and Gentiana lutea using LC-MS and RP-HPLC [J].
Aberham, Anita ;
Pieri, Valerio ;
Croom, Edward M., Jr. ;
Ellmerer, Ernst ;
Stuppner, Hermann .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 54 (03) :517-525
[2]  
[Anonymous], P I ELECT ENG F
[3]   High-frequency embryogenesis and regeneration of plants with high content of gentiopicroside from the Chinese medicinal plant Gentiana straminea Maxim. [J].
Cai, Yunfei ;
Liu, Yanling ;
Liu, Zhenhua ;
Zhang, Feng ;
Xiang, Fengning ;
Xia, Guangmin .
IN VITRO CELLULAR & DEVELOPMENTAL BIOLOGY-PLANT, 2009, 45 (06) :730-739
[4]   High-order contrasts for independent component analysis [J].
Cardoso, JF .
NEURAL COMPUTATION, 1999, 11 (01) :157-192
[5]  
Chen S, 2010, P 6 INT WORKSH NOND, P32
[6]   Nondestructive Differentiation of Panax Species Using Visible and Shortwave Near-Infrared Spectroscopy [J].
Chen, Xiaojing ;
Wu, Di ;
He, Yong ;
Liu, Shou .
FOOD AND BIOPROCESS TECHNOLOGY, 2011, 4 (05) :753-761
[7]   Integration of Independent Component Analysis with Near Infrared Spectroscopy for Rapid Quantification of Sugar Content in Wax Jambu (Syzygium samarangense Merrill & Perry) [J].
Chuang, Yung-Kun ;
Chen, Suming ;
Lo, Y. Martin ;
Tsai, Chao-Yin ;
Yang, I-Chang ;
Chen, Yu-Liang ;
Pan, Pei-Ju ;
Chen, Chien-Chih .
JOURNAL OF FOOD AND DRUG ANALYSIS, 2012, 20 (04) :855-864
[8]  
Fang LM, 2008, ACTA CHIM SINICA, V66, P1791
[9]   Determination of gentiopicroside in extracts of Centaurium erythreae and Gentiana lutea by micellar electrokinetic capillary chromatography [J].
Glatz, Z ;
Pospísilová, J ;
Musil, P .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2000, 23 (12) :1831-1839
[10]   RELATED VERSIONS OF THE MULTIPLICATIVE SCATTER CORRECTION METHOD FOR PREPROCESSING SPECTROSCOPIC DATA [J].
HELLAND, IS ;
NAES, T ;
ISAKSSON, T .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1995, 29 (02) :233-241