Clinical and prognostic value of stress echocardiography appropriateness criteria for evaluation of coronary artery disease in a tertiary referral centre

被引:17
作者
Bhattacharyya, Sanjeev [1 ,2 ]
Kamperidis, Vasilis [1 ,2 ]
Chahal, Navtej [1 ,2 ]
Shah, Benoy N. [1 ,2 ]
Roussin, Isabelle [1 ,2 ]
Li, Wei [1 ,2 ]
Khattar, Rajdeep [1 ,2 ,3 ]
Senior, Roxy [1 ,2 ,3 ]
机构
[1] Royal Brompton & Harefield NHS Trust, Dept Cardiol, London, England
[2] Royal Brompton & Harefield NHS Trust, Echocardiog Lab, London, England
[3] Univ London Imperial Coll Sci Technol & Med, Natl Heart & Lung Inst, Biomed Res Unit, London, England
关键词
Coronary Artery Disease; TEMPORAL TRENDS; MORTALITY; SOCIETY;
D O I
10.1136/heartjnl-2013-304949
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective Appropriateness criteria for stress echocardiography (SE) have been published to reduce the rate of inappropriate testing. We sought to investigate the clinical impact and prognostic value of these criteria. Methods 250 consecutive patients undergoing SE for evaluation of coronary artery disease were classified into appropriate, uncertain and inappropriate categories according to appropriateness criteria. A positive SE was defined as the development of new wall motion abnormalities or a biphasic response. The primary end point was the composite of myocardial infarction and death. Results Of the 250 SE, 120 (48%) were dobutamine studies and 130 (52%) were exercise studies. 156 (62.4%), 71 (28.4%) and 23 (9.2%) were classified as appropriate, inappropriate and uncertain, respectively. A significantly greater proportion of studies classified as appropriate 71 (45.5%) demonstrated inducible ischaemia compared with inappropriate studies 9 (12.7%) or uncertain studies 4 (17.4%), p<0.0001. During a median follow-up of 12.4months, events occurred in 18 (11.5%), 2 (2.8%) and 0 patients classified as appropriate, inappropriate and uncertain, respectively. Event-free survival was significantly reduced in patients with a SE demonstrating ischaemia compared with patients without inducible ischaemia, p<0.0001. Kaplan-Meier curves demonstrated reduced event-free survival in patients with whose studies were classified as appropriate compared to inappropriate (p=0.01) or uncertain (p=0.05). Conclusions Appropriateness criteria differentiate between patients at high risk of ischaemia, subsequent revascularisation/cardiac events (appropriate group) and those at low risk of events (inappropriate group). A large proportion of SE is currently performed in inappropriate patients. Implementation of the criteria in clinical practice would reduce unnecessary testing.
引用
收藏
页码:370 / 374
页数:5
相关论文
共 15 条
  • [1] Optimal medical therapy with or without PCI for stable coronary disease
    Boden, William E.
    O'Rourke, Robert A.
    Teo, Koon K.
    Hartigan, Pamela M.
    Maron, David J.
    Kostuk, William J.
    Knudtson, Merril
    Dada, Marcin
    Casperson, Paul
    Harris, Crystal L.
    Chaitman, Bernard R.
    Shaw, Leslee
    Gosselin, Gilbert
    Nawaz, Shah
    Title, Lawrence M.
    Gau, Gerald
    Blaustein, Alvin S.
    Booth, David C.
    Bates, Eric R.
    Spertus, John A.
    Berman, Daniel S.
    Mancini, G. B. John
    Weintraub, William S.
    Boden, W.
    O'Rourke, R.
    Teo, K.
    Hartigan, P.
    Weintraub, W.
    Maron, D.
    Mancini, J.
    Weintraub, W.
    Boden, W.
    O'Rourke, R.
    Teo, K.
    Hartigan, P.
    Knudtson, M.
    Maron, D.
    Bates, E.
    Blaustein, A.
    Booth, D.
    Carere, R.
    Ellis, S.
    Gosselin, G.
    Gau, G.
    Jacobs, A.
    King, S., III
    Kostuk, W.
    Harris, C.
    Spertus, J.
    Peduzzi, P.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2007, 356 (15) : 1503 - 1516
  • [2] Cortigiani L, 2012, CIRC-CARDIOVASC IMAG, V5, P298, DOI 10.1161/CIRCIMAGING.111.971242
  • [3] ACCF/ASE/AHA/ASNC/HFSA/HRS/SCAI/SCCM/SCCT/SCMR 2011 Appropriate Use Criteria for Echocardiography
    Douglas, Pamela S.
    Garcia, Mario J.
    Haines, David E.
    Lai, Wyman W.
    Manning, Warren J.
    Patel, Ayan R.
    Picard, Michael H.
    Polk, Donna M.
    Ragosta, Michael
    Ward, R. Parker
    Weiner, Rory B.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (09) : 1126 - 1166
  • [4] Frye RL., 2009, NEW ENGL J MED, V360, P2503, DOI [DOI 10.1056/NEJMOA0805796, 10.1056/NEJMoa0805796]
  • [5] Appropriate Use Criteria For Stress Single-Photon Emission Computed Tomography Sestamibi Studies A Quality Improvement Project
    Gibbons, Raymond J.
    Askew, J. Wells
    Hodge, David
    Kaping, Beth
    Carryer, Damita J.
    Miller, Todd
    [J]. CIRCULATION, 2011, 123 (05) : 499 - 503
  • [6] Temporal trends in the utilization of diagnostic testing and treatments for cardiovascular disease in the United States, 1993-2001
    Lucas, FL
    DeLorenzo, MA
    Siewers, AE
    Wennberg, DE
    [J]. CIRCULATION, 2006, 113 (03) : 374 - 379
  • [7] Evaluation of the Clinical Application of the ACCF/ASE Appropriateness Criteria for Stress Echocardiography
    Mansour, Ibrahim N.
    Lang, Roberto M.
    Aburuwaida, Waseem M.
    Bhave, Nicole M.
    Ward, R. Parker
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2010, 23 (11) : 1199 - 1204
  • [8] Prediction of mortality using dobutamine echocardiography
    Marwick, TH
    Case, C
    Sawada, S
    Rimmerman, C
    Brenneman, P
    Kovacs, R
    Short, L
    Lauer, M
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (03) : 754 - 760
  • [9] Applicability of Appropriateness Criteria for Stress Imaging Similarities and Differences Between Stress Echocardiography and Single-Photon Emission Computed Tomography Myocardial Perfusion Imaging Criteria
    McCully, Robert B.
    Pellikka, Patricia A.
    Hodge, David O.
    Araoz, Philip A.
    Miller, Todd D.
    Gibbons, Raymond J.
    [J]. CIRCULATION-CARDIOVASCULAR IMAGING, 2009, 2 (03) : 213 - 218
  • [10] Exercise capacity and mortality among men referred for exercise testing
    Myers, J
    Prakash, M
    Froelicher, V
    Do, D
    Partington, S
    Atwood, JE
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2002, 346 (11) : 793 - 801