Mercury Emissions Control in Coal Combustion Systems Using Potassium Iodide: Bench-Scale and Pilot-Scale Studies

被引:24
|
作者
Li, Ying [1 ]
Daukoru, Michael [1 ]
Suriyawong, Achariya [1 ]
Biswas, Pratim [1 ]
机构
[1] Washington Univ, Aerosol & Air Qual Res Lab, Dept Energy Environm & Chem Engn, St Louis, MO 63130 USA
关键词
FIRED POWER-PLANTS; FLUE-GAS; ELEMENTAL MERCURY; BITUMINOUS COAL; OXIDATION; REMOVAL; INJECTION; CATALYSTS;
D O I
10.1021/ef800656v
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Addition of halogens or halides has been reported to promote mercury removal in coal-fired power plants. In this study, bench- and pilot-scale experiments were conducted using potassium iodide (KI) for capture and removal of Hg in air and coal combustion exhaust. Two bench-scale reactor systems were used: (1) a packed-bed reactor (PBR) packed with granular or powder KI and (2) an aerosol flow reactor (AFR) with injection of KI particles. It was found that a higher temperature, a higher concentration of KI, and a longer gas residence time resulted in a higher Hg removal efficiency. A 100% Hg removal was achieved in the PBR above 300 degrees C using 0.5 g of powder KI and in the AFR above 500 degrees C with a KI/Hg molar ratio of 600 at a 5.8 s residence time. The low KI injection ratio relative to Hg indicated that KI is highly effective for Hg removal in air. Formation Of I-2 vapor by the oxidation of KI by O-2 at high temperatures, which then reacts with Hg to produce HgI2, was identified as the pathway for removal. The pilot-scale experiments were conducted in a 160 kW pulverized coal combustor. KI was introduced in two ways: as a powder mixed with coal and by spraying KI solution droplets into the flue gas. In both cases the Hg removal efficiency increased with an increase in the feed rate of KI. Mixing KI powder with coal was found to be more effective than spraying KI into the flue gas, very likely due to the higher temperature, longer residence time of KI, and the formation of a secondary reactive sorbent. The Hg removal by KI was less efficient in the pilot-scale tests than in the bench-scale tests probably due to certain flue gas components reacting with KI or I-2. Hg speciation measurements in both bench-and pilot-scale experiments indicated no oxidized mercury in the gas phase upon introduction of KI, indicating that the oxidation product HgI2 was captured in the particulate phase. This is very beneficial in coal-fired power plants equipped with electrostatic precipitators where particulate-bound Hg can be efficiently removed.
引用
收藏
页码:236 / 243
页数:8
相关论文
共 50 条
  • [21] Reverse osmosis applied to soil remediation wastewater: Comparison between bench-scale and pilot-scale results
    Roy, Dany
    Gherrou, Abdelaziz
    Pierre, Pascale
    Landry, Dany
    Yargeau, Viviane
    JOURNAL OF WATER PROCESS ENGINEERING, 2017, 16 : 115 - 122
  • [22] A comparison of the critical impeller speed for solids suspension in a bench-scale and a pilot-scale mechanical flotation cell
    Lima, O. A.
    Deglon, D. A.
    Leal Filho, L. S.
    MINERALS ENGINEERING, 2009, 22 (13) : 1147 - 1153
  • [23] Pilot-scale study on NO emissions from coarse coal combustion preheated by circulating fluidized bed
    Zhu, Shujun
    Zhu, Jianguo
    Lyu, Qinggang
    Liu, Jingzhang
    Ouyang, Ziqu
    FUEL, 2020, 280
  • [24] Emissions from carpet combustion in a pilot-scale rotary kiln: Comparison with coal and particle-board combustion
    Konopa, Stephanie Lucero
    Mulholland, James A.
    Realff, Matthew J.
    Lemieux, Paul M.
    JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2008, 58 (08): : 1070 - 1076
  • [25] Experimental Study of Coal MILD Combustion at a Pilot-Scale Furnace
    Mao, Zhihui
    Zhang, Liqi
    Zhu, Xinyang
    Zheng, Chuguang
    CLEAN COAL TECHNOLOGY AND SUSTAINABLE DEVELOPMENT, 2016, : 173 - 181
  • [26] Scaling Up the Performance of a Reactor Model for Hydrotreating Vegetable Oil from Bench-Scale to Pilot-Scale Reactors
    Tirado, Alexis
    Ancheyta, Jorge
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2020, 59 (50) : 21712 - 21719
  • [27] Qualification of Bench and Pilot-Scale Bioreactors as Models of Commercial Systems
    Molloy, Anne Marie
    Dowling, Patrick
    Looby, Mairead
    Crawford, Caitriona
    Tangarone, Bruce
    Heenan, Mary
    Moran, Enda
    PROCEEDINGS OF THE 21ST ANNUAL MEETING OF THE EUROPEAN SOCIETY FOR ANIMAL CELL TECHNOLOGY (ESACT), 2009, 2012, 5 : 67 - 70
  • [28] Novel electro-dewatering system for activated sludge biosolids in bench-scale, pilot-scale and industrial-scale applications
    Zhang, Shuting
    Yang, Zengjun
    Lv, Xuebin
    Zhi, Suli
    Wang, Yiwei
    Li, Qian
    Zhang, Keqiang
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2017, 121 : 44 - 56
  • [29] Tower bio-vermifilter system for rural wastewater treatment: bench-scale, pilot-scale, and engineering applications
    Nie, E.
    Wang, D.
    Yang, M.
    Luo, X.
    Fang, C.
    Yang, X.
    Su, D.
    Zhou, L.
    Zheng, Z.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2015, 12 (03) : 1053 - 1064
  • [30] Tower bio-vermifilter system for rural wastewater treatment: bench-scale, pilot-scale, and engineering applications
    E. Nie
    D. Wang
    M. Yang
    X. Luo
    C. Fang
    X. Yang
    D. Su
    L. Zhou
    Z. Zheng
    International Journal of Environmental Science and Technology, 2015, 12 : 1053 - 1064