The impact of data-driven respiratory gating in clinical F-18 FDG PET/CT: comparison of free breathing and deep-expiration breath-hold CT protocol

被引:20
作者
Kang, Seo Young [1 ]
Moon, Byung Seok [1 ]
Kim, Hye Ok [1 ]
Yoon, Hai-Jeon [1 ]
Kim, Bom Sahn [1 ]
机构
[1] Ewha Womans Univ, Med Ctr, Coll Med, Dept Nucl Med, 260 Gonghang Daero, Seoul 07804, South Korea
基金
新加坡国家研究基金会;
关键词
Data-driven respiratory gating; F-18-FDG PET/CT; Respiratory movement; Free breathing CT; Deep-expiration breath-hold CT; SPATIAL ALIGNMENT; GATED PET; MOTION; IMAGES;
D O I
10.1007/s12149-020-01574-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Respiratory motion can diminish PET image quality and lead to inaccurate lesion quantifications. Data-driven gating (DDG) was recently introduced as an effective respiratory gating technique for PET. In the current study, we investigated the clinical impact of DDG on respiratory movement in F-18-FDG PET/CT. Method PET list-mode data were collected for each subject and DDG software was utilized for extracting respiratory waveforms. PET images was reconstructed using Q.clear and Q.clear + DDG, respectively. We evaluated SUVmax, SUVmean, the coefficient of variance (CoV), metabolic tumor volume (MTV), and tumor heterogeneity using the area under the curve of cumulative SUV histogram (AUC-CSH). Metabolic parameter changes were compared between each reconstruction method. The Deep-Expiration Breath Hold (DEBH) protocol was introduced for CT scans to correct spatial misalignment between PET and CT and compared with conventional free breathing. The DEBH and free breathing (FB) protocol comparison was made in a separate matching cohort using propensity core matching rather than the same patient. Results Total 147 PET/CT scans with excessive respiratory movements were used to study DDG-mediated correction. After DDG application, SUVmax (P < 0.0001; 8.15 +/- 4.77 vs. 9.03 +/- 5.02) and SUVmean (P < 0.0001; 4.91 +/- 2.44 vs. 5.49 +/- 2.68) of lung and upper abdomen lesions increased, while MTV significantly decreased (P < 0.0001; 7.07 +/- 15.46 vs. 6.58 +/- 15.14). In addition, the percent change of SUVs was greater in lower lung lesions compared to upper lobe lesions. Likewise, the MTV reduction was significantly greater in lower lobe lesions. No significant difference dependent on location was observed in liver lesions. DEBH-mediated CT breathing correction did not make a significant difference in lesion metabolic parameters compared to conventional free breathing. Conclusions These results suggest that DDG correction enables more corrected quantification from respiratory movements for lesions located in the lung and upper abdomen. Therefore, we suggest that DDG is worth using as a standard protocol during F-18-FDG PET/CT imaging.
引用
收藏
页码:328 / 337
页数:10
相关论文
共 30 条
  • [1] Allen-Auerbach M, 2006, J NUCL MED, V47, P298
  • [2] Dual-modality PET/CT imaging: the effect of respiratory motion on combined image quality in clinical oncology
    Beyer, T
    Antoch, G
    Blodgett, T
    Freudenberg, LF
    Akhurst, T
    Mueller, S
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2003, 30 (04) : 588 - 596
  • [3] External radioactive markers for PET data-driven respiratory gating in positron emission tomography
    Buether, Florian
    Ernst, Iris
    Hamill, James
    Eich, Hans T.
    Schober, Otmar
    Schaefers, Michael
    Schaefers, Klaus P.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 (04) : 602 - 614
  • [4] Respiratory-Gated Positron Emission Tomography and Breath-Hold Computed Tomography Coupling to Reduce the Influence of Respiratory Motion: Methodology and Feasibility
    Daouk, J.
    Fin, L.
    Bailly, P.
    Meyer, M. -E.
    [J]. ACTA RADIOLOGICA, 2009, 50 (02) : 144 - 155
  • [5] Optimal CT breathing protocol for combined thoracic PET/CT
    Gilman, Matthew D.
    Fischman, Alan J.
    Krishnasetty, Vikram
    Halpern, Elkan F.
    Aquino, Suzanne L.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 187 (05) : 1357 - 1360
  • [6] Deep-inspiration breath-hold PET/CT of lung cancer: Maximum standardized uptake value analysis of 108 patients
    Kawano, Tsuyoshi
    Ohtake, Eiji
    Inoue, Tornio
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2008, 49 (08) : 1223 - 1231
  • [7] The management of respiratory motion in radiation oncology report of AAPM Task Group 76
    Keall, Paul J.
    Mageras, Gig S.
    Balter, James M.
    Emery, Richard S.
    Forster, Kenneth M.
    Jiang, Steve B.
    Kapatoes, Jeffrey M.
    Low, Daniel A.
    Murphy, Martin J.
    Murray, Brad R.
    Ramsey, Chester R.
    Van Herk, Marcel B.
    Vedam, S. Sastry
    Wong, John W.
    Yorke, Ellen
    [J]. MEDICAL PHYSICS, 2006, 33 (10) : 3874 - 3900
  • [8] Validation of Software Gating: A Practical Technology for Respiratory Motion Correction in PET
    Kesner, Adam Leon
    Chung, Jonathan Hero
    Lind, Kimberly Erin
    Kwak, Jennifer Jihyang
    Lynch, David
    Burckhardt, Darrell
    Koo, Phillip Jahhyung
    [J]. RADIOLOGY, 2016, 281 (01) : 239 - 248
  • [9] The impact of respiratory motion on tumor quantification and delineation in static PET/CT imaging
    Liu, Chi
    Pierce, Larry A., II
    Alessio, Adam M.
    Kinahan, Paul E.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (24) : 7345 - 7362
  • [10] PCA-derived respiratory motion surrogates from X-ray angiograms for percutaneous coronary interventions
    Ma, Hua
    Dibildox, Gerardo
    Schultz, Carl
    Regar, Evelyn
    van Walsum, Theo
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2015, 10 (06) : 695 - 705