Calibration of Correlation Radiometers Using Pseudo-Random Noise Signals

被引:23
作者
Ramos Perez, Isaac [1 ]
Bosch-Lluis, Xavi [1 ]
Camps, Adriano [1 ]
Rodriguez Alvarez, Nereida [1 ]
Marchan Hernandez, Juan Fernando [1 ]
Valencia Domenech, Enric [1 ]
Vernich, Carlos [2 ]
de la Rosa, Sonia [2 ]
Pantoja, Sebastian [2 ]
机构
[1] Univ Politecn Cataluna, Remote Sensing Lab, Dept Signal Theory & Commun, E-08034 Barcelona, Spain
[2] DAS Photon, Ciudad Politecn Innovac, E-46022 Valencia, Spain
来源
SENSORS | 2009年 / 9卷 / 08期
关键词
correlation radiometers; calibration; Pseudo-Random Noise; PRN; APERTURE SYNTHESIS RADIOMETERS; INTERFEROMETRIC RADIOMETERS; L-BAND; RECEIVER;
D O I
10.3390/s90806131
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The calibration of correlation radiometers, and particularly aperture synthesis interferometric radiometers, is a critical issue to ensure their performance. Current calibration techniques are based on the measurement of the cross-correlation of receivers' outputs when injecting noise from a common noise source requiring a very stable distribution network. For large interferometric radiometers this centralized noise injection approach is very complex from the point of view of mass, volume and phase/amplitude equalization. Distributed noise injection techniques have been proposed as a feasible alternative, but are unable to correct for the so-called "baseline errors" associated with the particular pair of receivers forming the baseline. In this work it is proposed the use of centralized Pseudo-Random Noise (PRN) signals to calibrate correlation radiometers. PRNs are sequences of symbols with a long repetition period that have a flat spectrum over a bandwidth which is determined by the symbol rate. Since their spectrum resembles that of thermal noise, they can be used to calibrate correlation radiometers. At the same time, since these sequences are deterministic, new calibration schemes can be envisaged, such as the correlation of each receiver's output with a baseband local replica of the PRN sequence, as well as new distribution schemes of calibration signals. This work analyzes the general requirements and performance of using PRN sequences for the calibration of microwave correlation radiometers, and particularizes the study to a potential implementation in a large aperture synthesis radiometer using an optical distribution network.
引用
收藏
页码:6131 / 6149
页数:19
相关论文
共 23 条
  • [1] [Anonymous], PASSIVE ADV UNIT PAU
  • [2] SMOS calibration
    Brown, Michael A.
    Torres, Francesc
    Corbella, Ignasi
    Colliander, Andreas
    [J]. IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2008, 46 (03): : 646 - 658
  • [3] Automatic calibration of channels frequency response in interferometric radiometers
    Camps, A
    Torres, F
    Bará, J
    Corbella, I
    Monzón, F
    [J]. ELECTRONICS LETTERS, 1999, 35 (02) : 115 - 116
  • [4] Redundant space calibration of hexagonal and Y-shaped beamforming radars and interferometric radiometers
    Camps, A
    Torres, F
    Lopez-Dekker, P
    Frasier, SJ
    [J]. INTERNATIONAL JOURNAL OF REMOTE SENSING, 2003, 24 (24) : 5183 - 5196
  • [5] New instrument concepts for ocean sensing:: Analysis of the PAU-radiometer
    Camps, Adriano
    Bosch-Lluis, Xavi
    Ramos-Perez, Isaac
    Marchan-Hernandez, Juan Fernando
    Izquierdo, Benjamin
    Rodriguez-Alvarez, Nereida
    [J]. IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2007, 45 (10): : 3180 - 3192
  • [6] CARLSTROM A, 2008, IEEE INT GEOSC REM S
  • [7] Analysis of noise-injection networks for interferometric-radiometer calibration
    Corbella, I
    Camps, A
    Torres, F
    Bará, J
    [J]. IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2000, 48 (04) : 545 - 552
  • [8] Cox C.H., 2004, ANALOG OPTICAL LINKS
  • [9] *DAS PHOT, 2008, SMOSOPS EST PREL VIA
  • [10] *ESA ITT AO, 2007, 1545607NLGLC ESA ITT