New polyacrylate-based lead(II) ion-selective electrodes

被引:24
|
作者
Lisak, Grzegorz [3 ,4 ,5 ]
Grygolowicz-Pawlak, Ewa [2 ]
Mazurkiewicz, Marta [2 ]
Malinowska, Elzbieta [2 ]
Sokalski, Tomasz [4 ,5 ]
Bobacka, Johan [4 ,5 ]
Lewenstam, Andrzej [1 ,4 ,5 ]
机构
[1] AGH Univ Sci & Technol, Fac Mat Sci & Ceram, PL-30059 Krakow, Poland
[2] Warsaw Univ Technol, Fac Chem, PL-00664 Warsaw, Poland
[3] Grad Sch Chem Sensors & Microanalyt Syst CHEMSEM, Espoo, Finland
[4] Abo Akad Univ, Analyt Chem Lab, FI-20500 Turku, Finland
[5] Abo Akad Univ, Ctr Proc Analyt Chem & Sensor Technol ProSens, Proc Chem Ctr, FI-20500 Turku, Finland
关键词
Polyacrylate membrane; Lead-selective electrode; Detection limit; Membrane fluxes; MEMBRANE ELECTRODES; INTERMEDIATE PHASE; SOLID-CONTACT; SENSORS; MONOLAYER; RANGE;
D O I
10.1007/s00604-008-0089-z
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel polyacrylate-based matrix for potentiometric ion-selective electrodes has been developed. Isododecyl acrylate, acrylonitrile and hexanedioldiacrylate co-monomers along with the thermo-initiator 2,2-dimethoxy-2-phenylacetophenone were used as polymeric matrix components. A lead(II)-selective electrode (Pb-ISE) was constructed using the above matrix. The electrode showed comparable analytical performance in the micromolar range to Pb-ISEs with conventional poly(vinyl chloride)-based membranes containing neutral ionophore and with solid-state membranes containing a mixture of lead sulphide and silver sulphide. Electrochemical impedance spectroscopy studies revealed much lower ion mobility in the polyacrylate membrane than in plasticized poly(vinyl chloride) membranes. This result additionally indicates the possibility of obtaining a lower detection limit for ISEs using the new acrylate matrix.
引用
收藏
页码:293 / 297
页数:5
相关论文
共 50 条
  • [1] New polyacrylate-based lead(II) ion-selective electrodes
    Grzegorz Lisak
    Ewa Grygolowicz-Pawlak
    Marta Mazurkiewicz
    Elzbieta Malinowska
    Tomasz Sokalski
    Johan Bobacka
    Andrzej Lewenstam
    Microchimica Acta, 2009, 164 : 293 - 297
  • [2] Method of achieving desired potentiometric responses of polyacrylate-based ion-selective membranes
    Michalska, Agata
    Pyrzynska, Krystyna
    Maksymiuk, Krzysztof
    ANALYTICAL CHEMISTRY, 2008, 80 (10) : 3921 - 3924
  • [3] LEAD(II) ION-SELECTIVE ELECTRODES BASED ON CROWN ETHERS
    SHEEN, SR
    SHIH, JS
    ANALYST, 1992, 117 (11) : 1691 - 1695
  • [4] Lead(II)-selective ionophores for ion-selective electrodes: A review
    Guzinski, Marcin
    Lisak, Grzegorz
    Kupis, Justyna
    Jasinski, Artur
    Bochenska, Maria
    ANALYTICA CHIMICA ACTA, 2013, 791 : 1 - 12
  • [5] Lead(II) and Copper(II) Ion-Selective Electrodes Based on Two Heterocyclic Compounds
    Yan, Zhenning
    Zhang, Qian
    Dan, Junying
    Guo, Yipeng
    Li, Liqin
    JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 66 (10) : 974 - 980
  • [6] Lead(II) and copper(II) ion-selective electrodes based on two heterocyclic compounds
    Zhenning Yan
    Qian Zhang
    Junying Dan
    Yipeng Guo
    Liqin Li
    Journal of Analytical Chemistry, 2011, 66 : 974 - 980
  • [7] SULFIDE ACTIVE MATERIALS FOR LEAD (II) ION-SELECTIVE ELECTRODES
    ITO, K
    MATSUDA, N
    MAEDA, T
    IKEDA, S
    IIDA, T
    NAKAGAWA, G
    DENKI KAGAKU, 1979, 47 (04): : 220 - 224
  • [8] STUDIES ON LEAD ION-SELECTIVE ELECTRODES BASED ON POLYALKOXYLATES
    JABER, AMY
    MOODY, GJ
    THOMAS, JDR
    ANALYST, 1988, 113 (09) : 1409 - 1413
  • [9] Electrochemical evidences and consequences of significant differences in ions diffusion rate in polyacrylate-based ion-selective membranes
    Woznica, Emilia
    Mieczkowski, Jozef
    Michalska, Agata
    ANALYST, 2011, 136 (22) : 4787 - 4793
  • [10] Pb(II)-ion-selective electrodes based on chalcogenide glasses
    Vassilev, V.
    Tomova, K.
    Boycheva, S.
    JOURNAL OF NON-CRYSTALLINE SOLIDS, 2007, 353 (29) : 2779 - 2784