Electrocatalytic oxidation and selective voltammetric detection of methyldopa in the presence of hydrochlorothiazide in real samples

被引:27
作者
Tajik, Somayeh [1 ,2 ]
Aflatoonian, Mohammad Reza [2 ,3 ]
Beitollahi, Hadi [4 ]
Shoaie, Iran Sheikh [5 ]
Dourandish, Zahra [5 ]
Fariba, Garkani Nejad [5 ]
Aflatoonian, Behnaz [2 ]
Bamorovat, Mehdi [3 ]
机构
[1] Kerman Univ Med Sci, Res Ctr Trop & Infect Dis, Kerman, Iran
[2] Kerman Univ Med Sci, Neurosci Res Ctr, Kerman, Iran
[3] Kerman Univ Med Sci, Leishmaniasis Res Ctr, Kerman, Iran
[4] Grad Univ Adv Technol, Inst Sci & High Technol & Environm Sci, Environm Dept, Kerman, Iran
[5] Shahid Bahonar Univ Kerman, Fac Sci, Dept Chem, Kerman 76175133, Iran
关键词
Zno nanoparticles; Amplified sensor; Methyldopa; Carbon paste electrode; Hydrochlorothiazide; GLASSY-CARBON ELECTRODE; PERFORMANCE LIQUID-CHROMATOGRAPHY; DOPED DIAMOND ELECTRODE; PASTE ELECTRODE; ELECTROCHEMICAL OXIDATION; HUMAN PLASMA; GRAPHENE; SENSOR; OXIDE; QUANTIFICATION;
D O I
10.1016/j.microc.2020.105182
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The combination of methyldopa and hydrocholorothiazide are used to treat high blood pressure. The present research dealt with the synthesis and utilization of the hexagonal-shaped of ZnO nanoparticles (NPs) to develop a new, sensitive, and exclusive electrochemical sensor for detection of methyldopa. Thus, we did our examination on the methyldopa detection via cyclic voltammetry (CV) method, differential pulse voltammetry (DPV) technique, and chronoamperometry (CH) at molybdenum (VI) complex-ionic liquid-ZnO NP modified carbon paste electrode (MCILZNMCPE) in 0.1 M PBS (pH of 7.0) solution. The use of DPV showed linear dependence of methyldopa peak current at pH of 7.0 solution on their concentration ranging between 0.05 and 300.0 mu M. Then, limit of detection (LOD) has been determined to be 20.0 nM for methyldopa. Ultimately, the modified electrode has been utilized for detecting methyldopa in the presence of hydrochlorothiazide by DPV.
引用
收藏
页数:8
相关论文
共 52 条
[1]  
Abdussalam-Mohammed W., 2020, ADV J CHEM A, V3, P192, DOI DOI 10.33945/SAMI/AJCA.2020.2.8
[2]   Electrochemical oxidation behavior of hydrochlorothiazide on a glassy carbon electrode and its voltammetric determination in pharmaceutical formulations and biological fluids [J].
Alghamdi, Ali F. .
JOURNAL OF FOOD AND DRUG ANALYSIS, 2014, 22 (03) :363-369
[3]   Spectrophotometric determination of methyldopa in pure and pharmaceutical preparations [J].
Aman, T ;
Khan, IU ;
Aslam, N ;
Ahmad, I .
ANALYTICAL LETTERS, 1998, 31 (06) :1007-1020
[4]   Voltammetric Sensor Based on 1-Benzyl-4-ferrocenyl-1H-[1,2,3]-triazole/Carbon Nanotube Modified Glassy Carbon Electrode; Detection of Hydrochlorothiazide in the Presence of Propranolol [J].
Baghbamidi, Sakineh Esfandiari ;
Beitollahi, Hadi ;
Tajik, Somayeh ;
Hosseinzadeh, Rahman .
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2016, 11 (12) :10874-10883
[5]   A Review on the Effects of Introducing CNTs in the Modification Process of Electrochemical Sensors [J].
Beitollahi, Hadi ;
Movahedifar, Fahimeh ;
Tajik, Somayeh ;
Jahani, Shohreh .
ELECTROANALYSIS, 2019, 31 (07) :1195-1203
[6]   Voltammetric analysis of cocaine hydrochloride at carbon paste electrode chemically modified with N,N′-ethylene-bis-(salicylideneiminato) manganese(II) Schiff base complex [J].
Castro, Alex Soares ;
Teles de Menezes, Matheus Manoel ;
Alves, Gustavo Murilo ;
de Oliveira, Marcelo Firmino .
MICROCHEMICAL JOURNAL, 2020, 153
[7]   EVALUATION OF THE POTENTIALITIES OF A CARBON NANOTUBES/SILICONE RUBBER COMPOSITE ELECTRODE IN THE DETERMINATION OF HYDROCHLOROTHIAZIDE [J].
dos Santos, Sidney Xavier ;
Gomes Cavalheiro, Eder Tadeu .
ANALYTICAL LETTERS, 2012, 45 (11) :1454-1466
[8]   Square wave voltammetry for analytical determination of paraquat at carbon paste electrode modified with fluoroapatite [J].
El Mhammedi, M. A. ;
Bakasse, M. ;
Bachirat, R. ;
Chtaini, A. .
FOOD CHEMISTRY, 2008, 110 (04) :1001-1006
[9]  
Eldefrawy M., 2018, P CHEM BIOCH RES, V1, P11
[10]   Simultaneous determination of irbesartan and hydrochlorothiazide in human plasma by liquid chromatography [J].
Erk, N .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 784 (01) :195-201