MetaboliteDetector: Comprehensive Analysis Tool for Targeted and Nontargeted GC/MS Based Metabolome Analysis

被引:346
作者
Hiller, Karsten [1 ]
Hangebrauk, Jasper [1 ]
Jager, Christian [1 ]
Spura, Jana [1 ]
Schreiber, Kerstin [1 ]
Schomburg, Dietmar [1 ]
机构
[1] Tech Univ Carolo Wilhelmina Braunschweig, Dept Bioinformat & Biochem, D-38106 Braunschweig, Germany
关键词
GAS CHROMATOGRAPHY/MASS SPECTROMETRY; LIQUID PARTITION CHROMATOGRAPHY; MASS-SPECTROMETRY; IDENTIFICATION; EXTRACTION; YEAST; ALIGNMENT; QUANTIFICATION; CULTURES; SPECTRA;
D O I
10.1021/ac802689c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We have developed a new software, MetaboliteDetector, for the efficient and automatic analysis of GC/MS-based metabolomics data. Starting with raw MS data, the program detects and subsequently identifies potential metabolites. Moreover, a comparative analysis of a large number of chromatograms can be performed in either a targeted or nontargeted approach. MetaboliteDetector automatically determines appropriate quantification ions and performs an integration of single ion peaks. The analysis results can directly be visualized with a principal component analysis. Since the manual. input is limited to absolutely necessary parameters, the program is also usable for the analysis of high-throughput data. However, the intuitive graphical user interface of MetabotiteDetector additionally allows for a detailed examination of a single GC/MS chromatogram including single ion chromatograms, recorded mass spectra, and identified metabolite spectra in combination with the corresponding reference spectra obtained from a reference library. MetaboliteDetector offers the ability to operate with. highly resolved profile mass data. Finally, all analysis results can be exported to tab delimited tables. The features of MetaboliteDetector are demonstrated by the analysis of two experimental metabolomics data. sets. MetaboliteDetector is freely available under the GNU public license (GPL) at http://metabolitedetector.tu.bs.de.
引用
收藏
页码:3429 / 3439
页数:11
相关论文
共 29 条
[1]   Alignment and statistical difference analysis of complex peptide data sets generated by multidimensional LC-MS [J].
America, AHP ;
Cordewener, JHG ;
van Geffen, MHA ;
Lommen, A ;
Vissers, JPC ;
Bino, RJ ;
Hall, RD .
PROTEOMICS, 2006, 6 (02) :641-653
[2]   MathDAMP: a package for differential analysis of metabolite profiles [J].
Baran, Richard ;
Kochi, Hayataro ;
Saito, Natsumi ;
Suematsu, Makoto ;
Soga, Tomoyoshi ;
Nishioka, Takaaki ;
Robert, Martin ;
Tomita, Masaru .
BMC BIOINFORMATICS, 2006, 7 (1)
[3]   XCMS2:: Processing tandem mass spectrometry data for metabolite identification and structural characterization [J].
Benton, H. P. ;
Wong, D. M. ;
Trauger, S. A. ;
Siuzdak, G. .
ANALYTICAL CHEMISTRY, 2008, 80 (16) :6382-6389
[4]   A high-throughput method for microbial metabolome analysis using gas chromatography/mass spectrometry [J].
Boerner, Jana ;
Buchinger, Sebastian ;
Schomburg, Dietmar .
ANALYTICAL BIOCHEMISTRY, 2007, 367 (02) :143-151
[5]   Homeostatic adjustment and metabolic remodeling in glucose-limited yeast cultures [J].
Brauer, MJ ;
Saldanha, AJ ;
Dolinski, K ;
Botstein, D .
MOLECULAR BIOLOGY OF THE CELL, 2005, 16 (05) :2503-2517
[6]   MET-IDEA: Data extraction tool for mass spectrometry-based metabolomics [J].
Broeckling, Corey D. ;
Reddy, Indira R. ;
Duran, Anthony L. ;
Zhao, Xuechun ;
Sumner, Lloyd W. .
ANALYTICAL CHEMISTRY, 2006, 78 (13) :4334-4341
[7]   MetaQuant:: a tool for the automatic quantification of GC/MS-based metabolome data [J].
Bunk, Boyke ;
Kucklick, Martin ;
Jonas, Rochus ;
Muench, Richard ;
Schobert, Max ;
Jahn, Dieter ;
Hiller, Karsten .
BIOINFORMATICS, 2006, 22 (23) :2962-2965
[8]   Retention index systems:: alternatives to the n-alkanes as calibration standards [J].
Castello, G .
JOURNAL OF CHROMATOGRAPHY A, 1999, 842 (1-2) :51-64
[9]   SPECTRAL DECONVOLUTION FOR OVERLAPPING GC MS COMPONENTS [J].
COLBY, BN .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1992, 3 (05) :558-562
[10]   Matched filtering with background suppression for improved quality of base peak chromatograms and mass spectra in liquid chromatography-mass spectrometry [J].
Danielsson, R ;
Bylund, D ;
Markides, KE .
ANALYTICA CHIMICA ACTA, 2002, 454 (02) :167-184