Microstructured semiconductor neutron detectors

被引:68
作者
McGregor, D. S. [1 ]
McNeil, W. J. [1 ]
Bellinger, S. L. [1 ]
Unruh, T. C. [1 ]
Shultis, J. K. [1 ]
机构
[1] Kansas State Univ, Dept Mech & Nucl Engn, SMART Lab, Manhattan, KS 66506 USA
基金
美国国家科学基金会;
关键词
Semiconductor neutron detectors; Solid state neutron detectors; EFFICIENCIES; DESIGN;
D O I
10.1016/j.nima.2009.06.031
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Perforated semiconductor neutron detectors are compact diode detectors that operate at low power and can be fashioned to have high thermal neutron detection efficiency. Fabricated from high-purity Si wafers, the perforations are etched into the diode surface with ICP-RIE and backfilled with (LiF)-Li-6 neutron reactive material. The intrinsic thermal neutron detection efficiency depends upon many factors, including the perforation geometry, size, and depth. Devices were fabricated from high resistivity 10 k Omega cm n-type Si with conformal p-type shallow junction diffusions into the perforations, which demonstrate improved neutron detection performance over previous selectively diffused designs. A comparison was made to previous selectively diffused designs, and pulse height spectra show improved signal-to-noise ratio, higher neutron counting efficiency, and excellent gamma-ray discrimination. Devices with 20 (average) mu m wide 100 mu m deep sinusoidal trenches yielded intrinsic thermal neutron detection efficiencies of 11.94 +/- 0.078%. (c) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:125 / 131
页数:7
相关论文
共 25 条
[1]  
Babcock RV., 1959, Nucleonics, V17, P116
[2]   Angular response of perforated silicon diode high efficiency neutron detectors [J].
Bellinger, S. L. ;
McNeil, W. J. ;
Unruh, T. C. ;
McGregor, D. S. .
2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, :1904-1907
[3]   Characteristics of 3D Micro-Structured Semiconductor High Efficiency Neutron Detectors [J].
Bellinger, S. L. ;
McNeil, W. J. ;
Unruh, T. C. ;
McGregor, D. S. .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (03) :742-746
[4]   GD-NEUTRON RECORDER [J].
FEIGL, B ;
RAUCH, H .
NUCLEAR INSTRUMENTS & METHODS, 1968, 61 (03) :349-&
[5]  
*IAEA, 1966, BIOGR SER IAEA, V18
[6]  
MCGREGOR D, 2003, Patent No. 6545281
[7]   Design considerations for thin film coated semiconductor thermal neutron detectors - I: basics regarding alpha particle emitting neutron reactive films [J].
McGregor, DS ;
Hammig, MD ;
Yang, YH ;
Gersch, HK ;
Klann, RT .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 500 (1-3) :272-308
[8]  
McGregor DS, 2002, IEEE NUCL SCI CONF R, P2401, DOI 10.1109/NSSMIC.2001.1009304
[9]   New surface morphology for low stress thin-film-coated thermal neutron detectors [J].
McGregor, DS ;
Klann, RT ;
Gersch, HK ;
Ariesanti, E ;
Sanders, JD ;
VanDerElzen, B .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (04) :1999-2004
[10]  
MCGREGOR DS, 2008, P SPIE, V7079