Automatic detection of the carotid lumen axis in B-mode ultrasound images

被引:12
作者
Rocha, Rui [1 ,2 ]
Silva, Jorge [1 ,3 ]
Campilho, Aurelio [1 ,3 ]
机构
[1] INESC Technol & Sci, INESC TEC, Oporto, Portugal
[2] ISEP, Oporto, Portugal
[3] Univ Porto, Fac Engn, P-4100 Oporto, Portugal
关键词
Ultrasound image; Carotid; Lumen axis; Image segmentation; Dynamic programming; Classification; MULTIINSTITUTIONAL DATABASE; IMT MEASUREMENT; ARTERY;
D O I
10.1016/j.cmpb.2014.04.004
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
A new approach is introduced for the automatic detection of the lumen axis of the common carotid artery in B-mode ultrasound images. The image is smoothed using a Gaussian filter and then a dynamic programming scheme extracts the dominant paths of local minima of the intensity and the dominant paths of local maxima of the gradient magnitude with the gradient pointing downwards. Since these paths are possible estimates of the lumen axis and the far wall of a blood vessel, respectively, they are grouped together into pairs. Then, a pattern of two features is computed from each pair of paths and used as input to a linear discriminant classifier in order to select the pair of paths that correspond to the common carotid artery. The estimated lumen axis is the path of local minima of the intensity that belongs to the selected pair of paths. The proposed method is suited to real time processing, no user interaction is required and the number of parameters is minimal and easy to determine. The validation was performed using two datasets, with a total of 199 images, and has shown a success rate of 99.5% (100% if only the carotid regions for which a ground truth is available are considered). The datasets have a large diversity of images, including cases of arteries with plaque and images with heavy noise, text or other graphical markings inside the artery region. (C) 2014 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:110 / 118
页数:9
相关论文
共 13 条
[1]  
[Anonymous], 2003, Statistical pattern recognition
[2]  
[Anonymous], 2000, Pattern Classification
[3]   Carotid artery intima-media thickness measured by ultrasonography in normal clinical practice correlates well with atherosclerosis risk factors [J].
Baldassarre, D ;
Amato, M ;
Bondioli, A ;
Sirtori, CR ;
Tremoli, E .
STROKE, 2000, 31 (10) :2426-2430
[4]  
Halenka Milan, 1999, Acta Universitatis Palackianae Olomucensis Facultatis Medicae, V142, P7
[5]  
Molinari F., 2012, IEEE T IMAGE P, V21
[6]   Ultrasound IMT measurement on a multi-ethnic and multi-institutional database: Our review and experience using four fully automated and one semi-automated methods [J].
Molinari, Filippo ;
Meiburger, Kristen M. ;
Saba, Luca ;
Acharya, U. Rajendra ;
Ledda, Giuseppe ;
Zeng, Guang ;
Ho, Sin Yee Stella ;
Ahuja, Anil T. ;
Ho, Suzanne C. ;
Nicolaides, Andrew ;
Suri, Jasjit S. .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2012, 108 (03) :946-960
[7]   Completely automated robust edge snapper for carotid ultrasound IMT measurement on a multi-institutional database of 300 images [J].
Molinari, Filippo ;
Acharya, U. Rajendra ;
Zeng, Guang ;
Meiburger, Kristen M. ;
Suri, Jasjit S. .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2011, 49 (08) :935-945
[8]   AUTOMATIC COMPUTER-BASED TRACINGS (ACT) IN LONGITUDINAL 2-D ULTRASOUND IMAGES USING DIFFERENT SCANNERS [J].
Molinari, Filippo ;
Liboni, William ;
Giustetto, Pierangela ;
Badalamenti, Sergio ;
Suri, Jasjit S. .
JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2009, 9 (04) :481-505
[9]   An Integrated Approach to Computer-Based Automated Tracing and Its Validation for 200 Common Carotid Arterial Wall Ultrasound Images A New Technique [J].
Molinari, Filippo ;
Zeng, Guang ;
Suri, Jasjit S. .
JOURNAL OF ULTRASOUND IN MEDICINE, 2010, 29 (03) :399-418
[10]   Ultrasound image segmentation and tissue characterization [J].
Noble, J. A. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2010, 224 (H2) :307-316