Load-deflection characteristics of superelastic nickel-titanium orthodontic wires

被引:89
作者
Wilkinson, PD
Dysart, PS
Hood, JAA
Herbison, GP
机构
[1] Univ Otago, Dept Oral Sci & Orthodont, Discipline Orthodont, Dunedin, New Zealand
[2] Univ Otago, Dept Oral Sci & Orthodont, Discipline Biomat, Dunedin, New Zealand
关键词
D O I
10.1067/mod.2002.121819
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Previous mechanical testing of orthodontic wires has, in many cases, failed to simulate some key features of the clinical environment. The purpose of this study was to investigate the load-deflection characteristics of 7 different 0.016-in initial alignment archwires (Twistflex, NiTi, and 5 brands of heat-activated superelastic nickel-titanium [HASN]) with modified bending tests simulating a number of conditions encountered clinically. Load-deflection tests were carried out on the wires with 5 different model designs, and data from selected points on the unloading phase of the generated graphs were statistically analyzed. Wire deflection was carried out at 3 temperatures (22.0degreesC, 35.5degreesC, and 44.0degreesC) and to 4 deflection distances (1 mm, 2 mm, 3 mm, and 4 mm). Rankings were derived according to statistically significant differences in each test situation. The effects of model, wire, and temperature variation were all statistically significant. Twistflex and the 5 HASN wires produced a range of broadly comparable results, and NiTi gave the highest unloading values. Model rankings indicated that self-ligating Twin-Lock brackets produced lower friction than regular edgewise brackets. The authors recommend using the rankings from the mechanical test simulations to predict possible clinical performance of archwires.
引用
收藏
页码:483 / 495
页数:13
相关论文
共 50 条
[21]   Properties of Superelastic Nickel-Titanium Wires after Clinical Use [J].
Alcaraz, Ines ;
Moyano, Javier ;
Pamies, Ariadna ;
Ruiz, Guillem ;
Artes, Montserrat ;
Gil, Javier ;
Puigdollers, Andreu .
MATERIALS, 2023, 16 (16)
[22]   Fatigue behaviour of nickel-titanium superelastic wires and endodontic instruments [J].
Bahia, M. G. A. ;
Gonzalez, B. M. ;
Buono, V. T. L. .
FATIGUE & FRACTURE OF ENGINEERING MATERIALS & STRUCTURES, 2006, 29 (07) :518-523
[23]   Comparison of the mechanical properties of orthodontic nickel-titanium wires [J].
Kayser, D ;
Bourauel, C ;
Braumann, B ;
Jäger, A .
BIOMEDIZINISCHE TECHNIK, 2002, 47 (12) :334-342
[25]   Electrochemical research on the corrosion of orthodontic nickel-titanium wires [J].
Vandenkerckhove, R ;
Temmerman, E ;
Verbeeck, R .
ELECTROCHEMICAL METHODS IN CORROSION RESEARCH VI, PTS 1 AND 2, 1998, 289-2 :1289-1298
[26]   DIFFERENCES IN THE PSEUDOELASTICITY BEHAVIOR OF NICKEL-TITANIUM ORTHODONTIC WIRES [J].
GIL, FJ ;
PLANELL, JA ;
LIBENSON, C .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1993, 4 (03) :281-284
[27]   Influence of stress and phase on corrosion of a superelastic nickel-titanium orthodontic wire [J].
Segal, Nadav ;
Hell, Jess ;
Berzins, David W. .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 135 (06) :764-770
[28]   Micro X-ray diffraction study of superelastic nickel-titanium orthodontic wires at different temperatures and stresses [J].
Iijima, M ;
Ohno, H ;
Kawashima, I ;
Endo, K ;
Brantley, WA ;
Mizoguchi, I .
BIOMATERIALS, 2002, 23 (08) :1769-1774
[29]   Mechanical behavior at different temperatures and stresses for superelastic nickel-titanium orthodontic wires having different transformation temperatures [J].
Iijima, M ;
Ohno, H ;
Kawashima, I ;
Endo, K ;
Mizoguchi, I .
DENTAL MATERIALS, 2002, 18 (01) :88-93
[30]   Surface composition and microtopography of nickel-titanium orthodontic wires. [J].
Bradley, TG ;
Mitchell, JC ;
Brantley, WA .
JOURNAL OF DENTAL RESEARCH, 1996, 75 :346-346