Nonenzymatic Electrochemical Superoxide Sensor

被引:16
作者
Nissim, Rita [1 ]
Compton, Richard G. [1 ]
机构
[1] Univ Oxford, Dept Chem, Phys & Theoret Chem Lab, Oxford OX1 3QZ, England
关键词
carbon electrodes; carbon paste electrodes; oxidation; reduction; sensors; NITRIC-OXIDE; REACTIVE OXYGEN; INVERT SOAP; REDUCTION; ANION; DISMUTASE; ELECTRODES; FILM; ANNOUNCMENT; GENERATION;
D O I
10.1002/celc.201300209
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The electrochemistry of nitroblue tetrazolium chloride (NBTC) was studied in aqueous solutions of pH 6.97 on a glassy carbon macroelectrode and at a carbon fibre microelectrode; values of near unity for the reduction transfer coefficient and 7.2 x 10(-6) cm(2) s(-1) for the diffusion coefficient were generated. The electrochemically produced diformazan was shown to adsorb on the glassy carbon surface if the potential was held at -0.35 V [vs. saturated calomel electrode (SCE)]. A carbon paste electrode, fabricated by using dioctyl phthalate and graphite powder, was used as a nonenzymatic sensor. The sensitivity of the diformazan oxidation signal to the presence of superoxide was exploited to detect superoxide, which is voltammetrically visible at about +0.69 V (vs. SCE). The paste electrode was first immersed in aqueous superoxide solutions. It was subsequently equilibrated with NBTC by immersing it into aqueous NBTC solutions. The reduction of NBTC (by superoxide) thus took place in the paste, which allowed quantification of the superoxide in the aqueous phase by means of the diformazan oxidation signal. Values for the practical limit of detection and the sensor sensitivity, 0.059 nm and 1.79 mu A nm(-1) respectively, were obtained.
引用
收藏
页码:763 / 771
页数:9
相关论文
共 51 条
[11]   QUANTITATIVE NITROBLUE TETRAZOLIUM TEST IN CHRONIC GRANULOMATOUS DISEASE [J].
BAEHNER, RL ;
NATHAN, DG .
NEW ENGLAND JOURNAL OF MEDICINE, 1968, 278 (18) :971-&
[12]   APPARENT HYDROXYL RADICAL PRODUCTION BY PEROXYNITRITE - IMPLICATIONS FOR ENDOTHELIAL INJURY FROM NITRIC-OXIDE AND SUPEROXIDE [J].
BECKMAN, JS ;
BECKMAN, TW ;
CHEN, J ;
MARSHALL, PA ;
FREEMAN, BA .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1990, 87 (04) :1620-1624
[13]   Detection of the Superoxide Radical Anion Using Various Alkanethiol Monolayers and Immobilized Cytochrome c [J].
Chen, Xiaojun J. ;
West, Alan C. ;
Cropek, Donald M. ;
Banta, Scott .
ANALYTICAL CHEMISTRY, 2008, 80 (24) :9622-9629
[14]  
Compton RG., 2018, UNDERSTANDING VOLTAM, DOI [DOI 10.1142/Q0155, DOI 10.1142/6430, 10.1142/q0155]
[15]   Superoxide radical sensing using a cytochrome c3 immobilized conducting polymer electrode [J].
Darain, Farzana ;
Park, Jang-Su ;
Akutsu, Hideo ;
Shim, Yoon-Bo .
BIOSENSORS & BIOELECTRONICS, 2007, 23 (02) :161-167
[16]   Third-generation superoxide anion sensor based on superoxide dismutase directly immobilized by sol-gel thin film on gold electrode [J].
Di, JW ;
Bi, SP ;
Zhang, M .
BIOSENSORS & BIOELECTRONICS, 2004, 19 (11) :1479-1486
[17]   ELECTROCHEMICAL GENERATION AND REACTIVITY OF SUPEROXIDE ION IN AQUEOUS-SOLUTIONS [J].
DIVISEK, J ;
KASTENING, B .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1975, 65 (02) :603-621
[18]   Phagocytosis - The mighty weapon of the silent warriors [J].
Djaldetti, M ;
Salman, H ;
Bergman, M ;
Djaldetti, R ;
Bessler, H .
MICROSCOPY RESEARCH AND TECHNIQUE, 2002, 57 (06) :421-431
[19]  
FLINT DH, 1993, J BIOL CHEM, V268, P22369
[20]   Superoxide sensor based on cytochrome c immobilized on mixed-thiol SAM with a new calibration method [J].
Ge, B ;
Lisdat, F .
ANALYTICA CHIMICA ACTA, 2002, 454 (01) :53-64