Thermal performance of sub-atmospheric two-phase loop thermosyphon at pitching and rolling conditions

被引:9
作者
Chang, Shyy Woei [1 ]
Huang, Bo Jyun [2 ]
机构
[1] Natl Kaohsiung Marine Univ, Thermal Fluids Lab, Kaohsiung, Taiwan
[2] Natl Kaohsiung Marine Univ, Dept Marine Engn, Kaohsiung, Taiwan
关键词
Two phase loop thermosyphon; Pitching rolling oscillations; Energy saving shipping machinery; HEAT-TRANSFER; NATURAL CIRCULATION; FLOW; PRESSURE; REACTOR; SURFACE; MOTION; DUCT;
D O I
10.1016/j.ijheatmasstransfer.2014.06.005
中图分类号
O414.1 [热力学];
学科分类号
摘要
With cooling applications to shipping machineries, thermal performances of static and swinging two-phase loop thermosyphons (TPLTs) operated at sub-atmospheric conditions are comparatively examined. The influences of pitching and/or rolling oscillations on the boiling flow structures and associated heat transfer characteristics, thermodynamic cycles and the constituent thermal resistances along the TPLT flow pathway are investigated. Flow visualization and thermal performance tests are individually performed at the identical test conditions controlled by boiling heater power (Q), condenser thermal resistance (R-th,R-con) and pitching/rolling frequencies to detect the boiling flow structures, boiling heat transfer rates, phase-change pressures in evaporator/condenser as well as the loop-wise compositions of the constituent thermal resistances. With present swinging TPLTs, the vapor bubbles in liquid pool yield to the disk-shape with the swaying bubble string centered at the nucleate site. Instead of the rigorous vapor bubble shooting in static evaporator channel at continuous boiling flow regime, the coherent vapor bubble cluster develops in the vapor dome of present swinging evaporator channel. Due to the swinging force effects on the boiling flow structures, the regionally averaged boiling heat transfer rates are initially reduced from the static references and followed by the subsequent increase as the swinging forces increase. The differential swinging force impacts at single pitching, single rolling and compound pitching and rolling test conditions on the boiling flow structures and heat transfer rates as well as the constituent and total thermal resistances are illustrated using a set of comparative results collected from the swinging and static TPLTs. The thermal resistances caused by boiling instabilities for present swinging TPLTs are considerably raised from the static references, leading to the noticeably elevations of cooling power consumptions. Two sets of empirical correlations, which permit the evaluations of boiling heat transfer rates and cooling power consumptions at various Q, R-th,R-con and pitching (Pi) or rolling (Ro) numbers are generated to assist the on-board applications. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:745 / 764
页数:20
相关论文
共 24 条
[1]   Boiling and evaporation in small diameter channels [J].
Bergles, AE ;
Lienhard, JH ;
Kendall, GE ;
Griffith, P .
HEAT TRANSFER ENGINEERING, 2003, 24 (01) :18-40
[2]  
Bowers M.B., 1994, ASME J ELECT PACKAGI, V116, P298
[3]   Thermal performance improvement with scale imprints over boiling surface of two-phase loop thermosyphon at sub-atmospheric conditions [J].
Chang, S. W. ;
Lin, C. Y. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2013, 56 (1-2) :294-308
[4]   Sub-atmospheric boiling heat transfer and thermal performance of two-phase loop thermosyphon [J].
Chang, S. W. ;
Lo, D. C. ;
Chiang, K. F. ;
Lin, C. Y. .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2012, 39 :134-147
[5]   Thermal performances of corrugated channel with skewed wall waves at rolling and pitching conditions [J].
Chang, Shyy Woei ;
Huang, Bo Jyun .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2012, 55 (17-18) :4548-4565
[6]   Turbulent heat transfer in a tube fitted with serrated twist tape under rolling and pitching environments with applications to shipping machineries [J].
Chang, Shyy Woei ;
Liou, Tong-Miin ;
Liou, Jin Shuen ;
Chen, Kun-Tse .
OCEAN ENGINEERING, 2008, 35 (16) :1569-1577
[7]   Heat transfer in a swinging rectangular duct with two opposite walls roughened by 45° staggered ribs [J].
Chang, SW ;
Su, LM ;
Yang, TL .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2004, 47 (02) :287-305
[8]  
Chang SW, 2002, J SHIP RES, V46, P149
[9]  
Chen G., 2014, TELKOMNIKA Indonesian Journal of Electrical Engineering, V12, P998
[10]  
Cooper M. G., 1984, First U.K. National Conference on Heat Transfer, P785