Application of glow discharge mass spectrometry to multielement ultra-trace determination in ultrahigh-purity copper and iron: a calibration approach achieving quantification and traceability

被引:62
作者
Matschat, Ralf
Hinrichs, Joachim
Kipphardt, Heinrich
机构
[1] Fed Inst Mat Res & Training BAM, D-12489 Berlin, Germany
[2] Thermo Electron Corp, D-28199 Bremen, Germany
关键词
glow discharge mass spectrometry (GD-MS); high-purity copper; high-purity iron; doped and pressed metal powder samples; grimm-type cell; metrological traceability;
D O I
10.1007/s00216-006-0645-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new approach was developed for quantitative calibration in GD-MS which can afford reliable and metrologically traceable results for many trace elements and was exemplified for pure copper and pure iron. It can be assumed that the technique can be further improved and applied to the analysis of other pure metals. Pressed copper and iron powder samples were used to calibrate the glow discharge mass spectrometry applied to the analysis of pure copper and iron. The new type of glow discharge mass spectrometer-the Element GD (Thermo Electron Corporation)-was used with a Grimm-type discharge cell for flat samples. Two series of powder samples were prepared for each of the copper and iron matrixes. The powders were quantitatively doped with solutions of graduated and defined concentrations of 40 or 20 analytes, respectively. The mass fractions of the analytes in the dried and homogenized metal powder samples ranged from mu g/kg levels up to 10 mg/kg levels. A special technique was developed to press the samples and to form mechanically stable pellets with low risk of contamination. Ion beam ratios of analyte ions to matrix ions were used as measurands. The calibration curves were determined and the linear correlation coefficients were calculated for different intervals of the curves. The linear correlation coefficients are very satisfactory for most of the calibration curves, which include the higher segments of mass fractions; however, they are less satisfactory for the lower segments of the calibration curves. Nevertheless, in many cases rather acceptable and rather promising values were achieved even for these lower segments, representing mass fractions of analytes at ultra-trace level. The comparison of the certified values of different reference materials with the measured values based on calibrations with the pressed powder samples led to deviations less than 30% for most of the considered examples.
引用
收藏
页码:125 / 141
页数:17
相关论文
共 30 条
[1]  
ABIKO K, 2002, 9 INT C ULTR PUR BAS
[2]  
[Anonymous], 1994, 32645 DIN
[3]   Use of a direct current glow discharge mass spectrometer for the chemical characterization of samples of nuclear concern [J].
Betti, M .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (09) :855-860
[4]   New developments and applications in GDMS [J].
Bogaerts, A ;
Gijbels, R .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 364 (05) :367-375
[5]  
*BUND MAT PRUF, 2004, BAMY001BAMY010
[6]   QUANTITATIVE-ANALYSIS OF IRON-RICH AND OTHER OXIDE-BASED SAMPLES BY MEANS OF GLOW-DISCHARGE MASS-SPECTROMETRY [J].
DEGENDT, S ;
SCHELLES, W ;
VANGRIEKEN, R ;
MULLER, V .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1995, 10 (09) :681-687
[7]   GLOW-DISCHARGE OPTICAL-EMISSION SPECTROSCOPY AS APPLIED TO THE ANALYSIS OF POWDERED MATERIALS [J].
EHRLICH, G ;
STAHLBERG, U ;
HOFFMANN, V ;
SCHOLZE, H .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1991, 46 (02) :115-124
[8]   SPECTROCHEMICAL ANALYSIS WITH A GLOW-DISCHARGE LAMP AS A LIGHT-SOURCE .3. DEVELOPMENT AND DESCRIPTION OF AN UNIVERSAL METHOD FOR DETERMINATION OF MAIN CONSTITUENTS IN ELECTRICALLY NON-CONDUCTING POWDER SAMPLES [J].
ELALFY, S ;
LAQUA, K ;
MASSMANN, H .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1973, 263 (01) :1-14
[9]   Recent trends in solid mass spectrometry: GDMS and other methods [J].
Gijbels, R ;
Bogaerts, A .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 359 (4-5) :326-330
[10]  
HINRICHS J, 2005, 30082 THERM EL CORP