Optimum formulae for heart rate correction of the QT interval

被引:63
作者
Hnatkova, K [1 ]
Malik, M [1 ]
机构
[1] St George Hosp, Sch Med, Dept Cardiol Sci, London SW17 0RE, England
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1999年 / 22卷 / 11期
关键词
QT interval; heart rate correction; linear regression analysis; nonlinear models;
D O I
10.1111/j.1540-8159.1999.tb00390.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The study investigated the performance of several generic QT/RR regression models in a dataset of QT and RR intervals obtained from resting electrocardiograms of 1,100 healthy subjects (913 male, mean age 33 +/- 12 years). All the investigated models have three degrees of freedom and included the hyperparabolic and hyper-hyperbolic models, algorithmic models, negative exponential models, and models involving inverse tangent, hyperbolic tangent, and inverse hyperbolic sign functions. For each generic model, the combination of parameters leading to the lowest regression residuum was found. The results of the study show that the goodness of the optimum fit is practically independent of the generic form of the regression model and that different datasets lead to different combinations of the numerical values of parameters of the corresponding regression models. The study concludes that the search for a universally applicable QT/RR regression model that would provide the best fit in all circumstances is most likely fruitless. Rather, individual studies such as those investigating drug related QT prolongation might benefit from establishing a best-fit regression that would provide the optimum model for each particular dataset.
引用
收藏
页码:1683 / 1687
页数:5
相关论文
共 14 条
[1]   CORRECTION OF THE QT INTERVAL FOR HEART-RATE - REVIEW OF DIFFERENT FORMULAS AND THE USE OF BAZETTS FORMULA IN MYOCARDIAL-INFARCTION [J].
AHNVE, S .
AMERICAN HEART JOURNAL, 1985, 109 (03) :568-574
[2]  
Bazett HC, 1920, HEART-J STUD CIRC, V7, P353
[3]  
Fridericia LS., 1920, Acta Med Scand, V53, P469, DOI DOI 10.1111/J.0954-6820.1920.TB18266.X
[4]   RATE-CORRECTED QT INTERVAL - TECHNIQUES AND LIMITATIONS [J].
FUNCKBRENTANO, C ;
JAILLON, P .
AMERICAN JOURNAL OF CARDIOLOGY, 1993, 72 (06) :B17-B22
[5]   RELATION BETWEEN QT INTERVALS AND HEART-RATES FROM 40 TO 120 BEATS/MIN IN REST ELECTROCARDIOGRAMS OF MEN AND A SIMPLE METHOD TO ADJUST QT INTERVAL VALUES [J].
KARJALAINEN, J ;
VIITASALO, M ;
MANTTARI, M ;
MANNINEN, V .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 23 (07) :1547-1553
[6]   QT interval dispersion and its clinical utility [J].
Kautzner, J ;
Malik, M .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (10) :2625-2640
[7]   RELATION BETWEEN QT INTERVAL AND HEART-RATE - APPLICATIONS AND LIMITATIONS OF BAZETT FORMULA [J].
KAWATAKI, M ;
KASHIMA, T ;
TODA, H ;
TANAKA, H .
JOURNAL OF ELECTROCARDIOLOGY, 1984, 17 (04) :371-376
[8]   THE MEASUREMENT OF THE Q-T-INTERVAL OF THE ELECTROCARDIOGRAM [J].
LEPESCHKIN, E ;
SURAWICZ, B .
CIRCULATION, 1952, 6 (03) :378-388
[9]   Correct the QT interval correctly: Should QT(c) be expressed in the same units as the QT interval? [J].
Malik, M ;
Camm, AJ .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (11) :1531-1534
[10]   THE MISSING-SECOND - WHAT IS THE CORRECT UNIT FOR THE BAZETT CORRECTED QT-INTERVAL [J].
MOLNAR, J ;
WEIS, JS ;
ROSENTHAL, JE .
AMERICAN JOURNAL OF CARDIOLOGY, 1995, 75 (07) :537-538