A study of large-volume on-column injection GC-ECD for the ultratrace analysis of organochlorine pesticides in water

被引:13
作者
Concha-Grana, E. [1 ]
Fernandez-Martinez, G. [2 ]
Fernandez-Villarrenaga, V. [2 ]
Turnes-Carou, M. I. [1 ]
Muniategui-Lorenzo, S. [1 ]
Lopez-Mahia, P. [1 ]
Prada-Rodriguez, D. [1 ]
机构
[1] Univ A Coruna, Dept Analyt Chem, E-15071 La Coruna, Spain
[2] Univ A Coruna, Sci Res Support Serv, E-15071 La Coruna, Spain
关键词
Organochlorine pesticides; Large-volume on-column injection (LVOCI); CC-ECD; Micro licluid-liquid extraction (MLLE); water analysis; SOLID-PHASE EXTRACTION; CAPILLARY GAS-CHROMATOGRAPHY; MASS SPECTROMETRY; TRACE ANALYSIS;
D O I
10.1016/j.talanta.2008.12.043
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, a large-volume on-column injection method for the analysis of 21 organochlorine pesticides, including HCH isomers. DDT derivatives and cyclodiene derivatives, was optimized. The solvent selected 10 Carry Out the study was ethyl acetate and the injection Volume was 100 mu l. Some factors were introduced in a Plackett-Burman design to determine their influence in the vaporization efficiency. The significant factors were then studied by a univariate procedure and sorted according to their importance on the response. The effect of the injection conditions on the peak resolution was also noted. The conditions selected according to sensitivity and resolution were: initial oven temperature 75 C, injection speed 20 mu l s(-1). solvent vapor exit (SVE) valve closure time 60s, initial pressure 100kPs and isothermal oven time 1 min. Analytical characteristics expressed in terms of precision,linear range, and limit of detection have been determined and compared with those obtained by splitless injection. The degradation of endrin and p,p'-DDT thermolabile pesticides was evaluated for both injection techniques. Finally the developed method was successfully applied to the ultratrace analysis of pesticides in natural waters. With this put-pose a micro licluid-liqUid extraction method using 2 nil of ethyl acetate to extract 10 nil of water sample was proposed. Recoveries between 69 and 107% were obtained with a very good precision (0.2-1.3%) for the studied pesticides, except for p,p'-DDD. Detection limits between 0.3 and 25 ngl(-1), which fulfill the limits established by the new water directive 2008/105/EC, were achieved. The MLLE method was compared with the SPE method by the analysis of some water samples using both procedures, and good concordance was obtained. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:764 / 771
页数:8
相关论文
共 27 条
[1]  
ANELLI L, 2001, AM LAB MAY, P45
[2]   Large volume cold on-column injection for gas chromatography-negative chemical ionization-mass spectrometry analysis of selected pesticides in air samples [J].
Bailey, Renata ;
Belzer, Wayne .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2007, 55 (04) :1150-1155
[3]   Determination of triazine herbicides by capillary gas chromatography with large-volume on-column injection [J].
Beltran, J ;
Lopez, FJ ;
Forcada, M ;
Hernandez, F .
CHROMATOGRAPHIA, 1997, 44 (5-6) :274-278
[4]   Large-volume injection in capillary gas chromatography using a programmed-temperature vaporizing injector in the on-column or solvent-vent injection mode [J].
Bosboom, JC ;
Janssen, HG ;
Mol, HGJ ;
Cramers, CA .
JOURNAL OF CHROMATOGRAPHY A, 1996, 724 (1-2) :384-391
[5]   Ultratraces analysis of organochlorine pesticides in drinking water by solid phase extraction coupled with large volume injection/gas chromatography/mass spectrometry [J].
Brondi, SHG ;
Spoljaric, FC ;
Lanças, FM .
JOURNAL OF SEPARATION SCIENCE, 2005, 28 (17) :2243-2246
[6]   Evaluation of HCH isomers and metabolites in soils, leachates, river water and sediments of a highly contaminated area [J].
Concha-Grana, E. ;
Turnes-Carou, M. I. ;
Muniategui-Lorenzo, S. ;
Lopez-Mahia, P. ;
Prada-Rodriguez, D. ;
Fernandez-Fernandez, E. .
CHEMOSPHERE, 2006, 64 (04) :588-595
[7]   Improvement of sensitivity in the determination of organochlorine pesticides using a PSS injector with GC-ECD [J].
Concha-Graña, E ;
Turnes-Carou, MI ;
Muniategui-Lorenzo, S ;
López-Mahía, P ;
Fernández-Fernández, E ;
Prada-Rodríguez, D .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 379 (7-8) :1120-1126
[8]   Optimisation of a programmed split-splitless injector in the gas chromatographic-mass spectrometric determination of organochlorine pesticides [J].
Concha-Graña, E ;
Turnes-Carou, MI ;
Muniategui-Lorenzo, S ;
López-Mahía, P ;
Fernández-Fernández, E ;
Prada-Rodríguez, D .
JOURNAL OF CHROMATOGRAPHY A, 2002, 958 (1-2) :17-24
[9]   Troubleshooting in the trace analysis of organochlorine pesticides in water samples [J].
Concha-Graña, E ;
Turnes-Carou, MI ;
Muniategui-Lorenzo, S ;
López-Mahia, P ;
Fernández-Fernández, E ;
Prada-Rodríguez, D .
CHROMATOGRAPHIA, 2001, 54 (7-8) :501-506
[10]   Comparison of different sorbents for multiresidue solid-phase extraction of 16 pesticides from groundwater coupled with high-performance liquid chromatography [J].
D'Archivio, Angelo Antonio ;
Fanelli, Maria ;
Mazzeo, Pietro ;
Ruggieri, Fabrizio .
TALANTA, 2007, 71 (01) :25-30