Product-experience reporting on endocardial defibrillation leads: a 4-year national perspective

被引:0
作者
Padeletti, Luigi [1 ]
Pappone, Carlo [6 ]
Curnis, Antonio [5 ]
Zanotto, Gabriele [4 ]
Calo, Leonardo [3 ]
Ricciardi, Giuseppe [1 ]
Pieragnoli, Paolo [1 ]
Dondina, Cristina [2 ]
Raciti, Giovanni [2 ]
Michelucci, Antonio [1 ]
机构
[1] Univ Florence, Careggi Hosp, Inst Internal Med & Cardiol, I-50134 Florence, Italy
[2] Boston Sci Corp, Milan, Italy
[3] Casilino Hosp, Unit Cardiol, Rome, Italy
[4] Borgo Trento Civile Maggiore Hosp, Unit Cardiol, Verona, Italy
[5] Univ & Spedali Civili, Unit Cardiol, Brescia, Italy
[6] San Raffaele Univ Hosp, Electrophysiol & Cardiac Pacing Unit, Dept Cardiol, Milan, Italy
关键词
endocardial lead; implantable cardioverter-defibrillator; patient safety; product performance report; IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS; EUROPEAN PERSPECTIVE; PACEMAKER; FAILURE; DEVICE; MANAGEMENT; EXTRACTION;
D O I
10.1586/ERD.09.22
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The medical device industry must implement accurate programs to monitor product performance once the product is released into the market. Product-experience reports provide a means for physicians who use medical devices to provide continuous feedback to manufacturers in order to monitor device performance. We examined product-experience reports sent from Italy over 4 years (2004-2007) related to a single manufacturer's family of permanent endocardial leads (Endotak Reliance (R), Boston Scientific, MA, USA) used with implantable cardioverter-defibrillators. Out of 15,772 implanted leads, physicians sent in 454 (2.87%) product-experience reports. Only 126 out of 454 (28%) leads were returned to the company; most of these (101 out of 126; 80%) were related to implant procedure. Laboratory analyses of returned leads rarely showed loss of integrity (0.01%). The practice of reporting product performance and returning the device to companies should be strongly encouraged in order to better identify potential issues affecting implantable devices.
引用
收藏
页码:383 / 388
页数:6
相关论文
共 28 条
  • [1] Management of recalled pacemakers and implantable cardioverter-defibrillators - A decision analysis model
    Amin, Mitesh S.
    Matchar, David B.
    Wood, Mark A.
    Ellenbogen, Kenneth A.
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2006, 296 (04): : 412 - 420
  • [2] Focus on management of pacemaker and ICD advisories, recalls, and alerts
    Amin M.S.
    Ellenbogen K.A.
    [J]. Current Treatment Options in Cardiovascular Medicine, 2006, 8 (5) : 347 - 352
  • [3] European Heart Rhythm Association Guidance Document on cardiac rhythm management product performance
    Auricchio, Angelo
    Gropp, Michael
    Ludgate, Susanne
    Vardas, Panos
    Brugada, Josep
    Priori, Silvia G.
    [J]. EUROPACE, 2006, 8 (05): : 313 - 322
  • [4] BONGIOMI MG, 2005, ITAL HEART J, V3, P261
  • [5] BYRD CL, 1999, PACING CLIN ELECTROP, V9, P1348
  • [6] When life-saving devices terminate life
    Catanchin, Andrei
    Anderson, Lisa
    Jones, Sue
    Ward, David
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2008, 19 (03) : 316 - 318
  • [7] Detection and management of an implantable cardioverter defibrillator lead failure - Incidence and clinical implications
    Ellenbogen, KA
    Wood, MA
    Shepard, RK
    Clemo, HF
    Vaughn, T
    Holloman, K
    Dow, M
    Leffler, J
    Abeyratne, A
    Verness, D
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (01) : 73 - 80
  • [8] Performance and survival of transvenous defibrillation leads: need for a European data registry
    Goette, Andreas
    Cantu, Francesco
    van Erven, Lieselot
    Geelen, Peter
    Halimi, Franck
    Merino, Jose L.
    Morgan, John M.
    [J]. EUROPACE, 2009, 11 (01): : 31 - 34
  • [9] Complications associated with implantable cardioverter-defibrillator replacement in response to device advisories
    Gould, PA
    Krahn, AD
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2006, 295 (16): : 1907 - 1911
  • [10] Development and testing of an algorithm to detect implantable cardioverter-defibrillator lead failure
    Gunderson, BD
    Gillberg, JM
    Wood, MA
    Vijayaraman, P
    Shepard, RK
    Elenbogen, KA
    [J]. HEART RHYTHM, 2006, 3 (02) : 155 - 162