Interface pressure, perceptual, and mean arterial pressure responses to different blood flow restriction systems

被引:46
作者
Hughes, L. [1 ,2 ]
Rosenblatt, B. [3 ]
Gissane, C. [1 ]
Paton, B. [2 ]
Patterson, S. D. [1 ]
机构
[1] St Marys Univ, Sch Sport Hlth & Appl Sci, London, England
[2] Inst Sport Exercise & Hlth, London, England
[3] Football Assoc, Burton Upon Trent, England
关键词
effectiveness; occlusion; pressure control; tourniquet pressure; RESISTANCE EXERCISE; CUFF WIDTH; OCCLUSION IMPLICATIONS; INTENSITY; TOURNIQUET;
D O I
10.1111/sms.13092
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
This study examined the cuff to limb interface pressure during blood flow restriction (BFR), and the perceptual and mean arterial pressure responses, in different BFR systems. Eighteen participants attended three experimental sessions in a randomised, crossover, counterbalanced design. Participants underwent inflations at 40% and 80% limb occlusive pressure (LOP) at rest and completed 4 sets of unilateral leg press exercise at 30% of one repetition maximum with BFR at 80% LOP. Different BFR systems were used each session: an automatic rapid-inflation (RI), automatic personalized tourniquet (PT) and manual handheld pump and sphygmomanometer (HS) system. Interface pressure was measured using a universal interface device with pressure sensors. Perceived exertion and pain were measured after each set, mean arterial pressure (MAP) was measured pre-, 1-minute post- and 5-minutes post-exercise. Interface pressure was lower than the set pressure in all BFR systems at rest (P<.05). Interface pressure was, on average, 10 +/- 8 and 48 +/- 36mm Hg higher than the set pressure in the RI and HS system (P<.01), with no differences observed in the PT system (P>.05), during exercise. Pain and exertion were greater in sets 3 and 4 in the RI and HS system compared to the PT system (P<.05). MAP was higher in the RI and HS system compared to the PT system at 1-minute and 5-minutes post-exercise (P<.05). BFR systems applying higher pressures amplify mean arterial pressure and perceptual responses. Automatic BFR systems appear to regulate pressure effectively within an acceptable range during BFR exercise.
引用
收藏
页码:1757 / 1765
页数:9
相关论文
共 40 条
[1]   A new paradigm for post-cardiac event resistance exercise guidelines [J].
Adams, J ;
Cline, MJ ;
Hubbard, M ;
McCullough, T ;
Hartman, J .
AMERICAN JOURNAL OF CARDIOLOGY, 2006, 97 (02) :281-286
[2]   World Medical Association Declaration of Helsinki Ethical Principles for Medical Research Involving Human Subjects [J].
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2013, 310 (20) :2191-2194
[3]  
[Anonymous], MED SCI SPORTS EXERC, DOI [10. 1097/00005768-199809000-00018, DOI 10.1097/00005768-199809000-00018]
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   Unilateral bicep curl hemodynamics: Low-pressure continuous vs high-pressure intermittent blood flow restriction [J].
Brandner, C. R. ;
Kidgell, D. J. ;
Warmington, S. A. .
SCANDINAVIAN JOURNAL OF MEDICINE & SCIENCE IN SPORTS, 2015, 25 (06) :770-777
[6]   Corticomotor Excitability is Increased Following an Acute Bout of Blood Flow Restriction Resistance Exercise [J].
Brandner, Christopher Roy ;
Warmington, Stuart Anthony ;
Kidgell, Dawson John .
FRONTIERS IN HUMAN NEUROSCIENCE, 2015, 9
[7]  
Cezar Marcos Antônio, 2016, Motriz: rev. educ. fis., V22, P9
[8]   The acute muscular response to two distinct blood flow restriction protocols [J].
Dankel, S. J. ;
Buckner, S. L. ;
Counts, B. R. ;
Jessee, M. B. ;
Mouser, J. G. ;
Mattocks, K. T. ;
Laurentino, G. C. ;
Abe, T. ;
Loenneke, J. P. .
PHYSIOLOGY INTERNATIONAL, 2017, 104 (01) :64-76
[9]   Tourniquet pain in a volunteer study: effect of changes in cuff width and pressure [J].
Estebe, JP ;
Le Naoures, A ;
Chemaly, L ;
Ecoffey, C .
ANAESTHESIA, 2000, 55 (01) :21-26
[10]  
Fahs CA., 2012, Journal of Trainology, V1, P14, DOI [10.17338/trainology.1.114, DOI 10.17338/TRAINOLOGY.1.1_14]