Automatic Segmentation of Corneal Microlayers on Optical Coherence Tomography Images

被引:14
|
作者
Elsawy, Amr [1 ,2 ]
Abdel-Mottaleb, Mohamed [2 ]
Sayed, Ibrahim-Osama [1 ]
Wen, Dan [1 ]
Roongpoovapatr, Vatookarn [1 ]
Eleiwa, Taher [1 ,3 ]
Sayed, Ahmed M. [1 ,4 ]
Raheem, Mariam [1 ]
Gameiro, Gustavo [1 ]
Abou Shousha, Mohamed [1 ,2 ,5 ]
机构
[1] Univ Miami, Miller Sch Med, Bascom Palmer Eye Inst, 900 Northwest 17th St, Miami, FL 33136 USA
[2] Univ Miami, Elect & Comp Engn, Coral Gables, FL 33136 USA
[3] Benha Fac Med, Ophthalmol Dept, Banha, Egypt
[4] Helwan Univ, Fac Engn, Biomed Engn Dept, Helwan, Egypt
[5] Univ Miami, Biomed Engn, Coral Gables, FL 33136 USA
来源
TRANSLATIONAL VISION SCIENCE & TECHNOLOGY | 2019年 / 8卷 / 03期
关键词
OCT imaging; segmentation; corneal microlayers; IN-VIVO CHARACTERISTICS; TOPOGRAPHIC THICKNESS; DIAGNOSIS; MEMBRANE; LAYER; OCT;
D O I
10.1167/tvst.8.3.39
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To propose automatic segmentation algorithm (AUS) for corneal microlayers on optical coherence tomography (OCT) images. Methods: Eighty-two corneal OCT scans were obtained from 45 patients with normal and abnormal corneas. Three testing data sets totaling 75 OCT images were randomly selected. Initially, corneal epithelium and endothelium microlayers are estimated using a corneal mask and locally refined to obtain final segmentation. Flat-epithelium and flat-endothelium images are obtained and vertically projected to locate inner corneal microlayers. Inner microlayers are estimated by translating epithelium and endothelium microlayers to detected locations then refined to obtain final segmentation. Images were segmented by trained manual operators (TMOs) and by the algorithm to assess repeatability (i.e., intraoperator error), reproducibility (i.e., interoperator and segmentation errors), and running time. A random masked subjective test was conducted by corneal specialists to subjectively grade the segmentation algorithm. Results: Compared with the TMOs, the AUS had significantly less mean intraoperator error (0.53 +/- 1.80 vs. 2.32 +/- 2.39 pixels; P < 0.0001), it had significantly different mean segmentation error (3.44 +/- 3.46 vs. 2.93 +/- 3.02 pixels; P < 0.0001), and it had significantly less running time per image (0.19 +/- 0.07 vs. 193.95 +/- 194.53 seconds; P < 0.0001). The AUS had insignificant subjective grading for microlayer-segmentation grading (4.94 +/- 032 vs. 4.96 +/- 0.24; P = 0.5081), but it had significant subjective grading for regional-segmentation grading (4.96 +/- 0.26 vs. 4.79 +/- 0.60; P = 0.025). Conclusions: The AUS can reproduce the manual segmentation of corneal microlayers with comparable accuracy in almost real-time and with significantly better repeatability. Translational Relevance: The AUS can be useful in clinical settings and can aid the diagnosis of corneal diseases by measuring thickness of segmented corneal microlayers.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Automatic Lumen Segmentation in Intravascular Optical Coherence Tomography Using Morphological Features
    Zhao, Huishuo
    He, Bin
    Ding, Zhenyang
    Tao, Kuiyuan
    Lai, Tianduo
    Kuang, Hao
    Liu, Rui
    Zhang, Xiaoguo
    Zheng, Yicheng
    Zheng, Junyi
    Liu, Tiegen
    IEEE ACCESS, 2019, 7 : 88859 - 88869
  • [42] Automatic Classification of Retinal Optical Coherence Tomography Images With Layer Guided Convolutional Neural Network
    Huang, Laifeng
    He, Xingxin
    Fang, Leyuan
    Rabbani, Hossein
    Chen, Xiangdong
    IEEE SIGNAL PROCESSING LETTERS, 2019, 26 (07) : 1026 - 1030
  • [43] Lightweight Learning-Based Automatic Segmentation of Subretinal Blebs on Microscope-Integrated Optical Coherence Tomography Images
    Song, Zhenxi
    Xu, Liangyu
    Wang, Jiang
    Rasti, Reza
    Sastry, Ananth
    Li, Jianwei D.
    Raynor, William
    Izatt, Joseph A.
    Toth, Cynthia A.
    Vajzovic, Lejla
    Deng, Bin
    Farsiu, Sina
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2021, 221 : 154 - 168
  • [44] Fast retinal layer segmentation of spectral domain optical coherence tomography images
    Zhang, Tianqiao
    Song, Zhangjun
    Wang, Xiaogang
    Zheng, Huimin
    Jia, Fucang
    Wu, Jianhuang
    Jia, Fucang
    Wu, Jianhuang
    Li, Guanglin
    Hu, Qingmao
    JOURNAL OF BIOMEDICAL OPTICS, 2015, 20 (09)
  • [45] Automated segmentation of intraretinal layers from macular optical coherence tomography images
    Haeker, Mona
    Sonka, Milan
    Kardon, Randy
    Shah, Vinay A.
    Wu, Xiaodong
    Abramoff, Michael D.
    MEDICAL IMAGING 2007: IMAGE PROCESSING, PTS 1-3, 2007, 6512
  • [46] ARTIFACTS IN AUTOMATIC RETINAL SEGMENTATION USING DIFFERENT OPTICAL COHERENCE TOMOGRAPHY INSTRUMENTS
    Giani, Andrea
    Cigada, Mario
    Esmaili, Daniel D.
    Salvetti, Paola
    Luccarelli, Saverio
    Marziani, Ermengarda
    Luiselli, Cristiano
    Sabella, Pierfilippo
    Cereda, Matteo
    Eandi, Chiara
    Staurenghi, Giovanni
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2010, 30 (04): : 607 - 616
  • [47] CGNet-assisted Automatic Vessel Segmentation for Optical Coherence Tomography Angiography
    Yu, Xiaojun
    Ge, Chenkun
    Aziz, Muhammad Zulkifal
    Li, Mingshuai
    Shum, Perry Ping
    Liu, Linbo
    Mo, Jianhua
    JOURNAL OF BIOPHOTONICS, 2022, 15 (10)
  • [48] Calcified plaque segmentation of intracoronary Optical Coherence Tomography images based on LBF
    Li, Qin
    Wang, Jingbo
    Liu, Wei
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS VIII, 2018, 10820
  • [49] WEAKLY-SUPERVISED AUTOMATIC BIOMARKERS DETECTION AND CLASSIFICATION OF RETINAL OPTICAL COHERENCE TOMOGRAPHY IMAGES
    Liu, Xiaoming
    Liu, Zhipeng
    Zhang, Ying
    Wang, Man
    Li, Bo
    Tang, Jinshan
    2021 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP), 2021, : 71 - 75
  • [50] SPARSITY-BASED RETINAL LAYER SEGMENTATION OF OPTICAL COHERENCE TOMOGRAPHY IMAGES
    Tokayer, Jason
    Ortega, Antonio
    Huang, David
    2011 18TH IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP), 2011, : 449 - 452