Automatic Segmentation of Corneal Microlayers on Optical Coherence Tomography Images

被引:14
|
作者
Elsawy, Amr [1 ,2 ]
Abdel-Mottaleb, Mohamed [2 ]
Sayed, Ibrahim-Osama [1 ]
Wen, Dan [1 ]
Roongpoovapatr, Vatookarn [1 ]
Eleiwa, Taher [1 ,3 ]
Sayed, Ahmed M. [1 ,4 ]
Raheem, Mariam [1 ]
Gameiro, Gustavo [1 ]
Abou Shousha, Mohamed [1 ,2 ,5 ]
机构
[1] Univ Miami, Miller Sch Med, Bascom Palmer Eye Inst, 900 Northwest 17th St, Miami, FL 33136 USA
[2] Univ Miami, Elect & Comp Engn, Coral Gables, FL 33136 USA
[3] Benha Fac Med, Ophthalmol Dept, Banha, Egypt
[4] Helwan Univ, Fac Engn, Biomed Engn Dept, Helwan, Egypt
[5] Univ Miami, Biomed Engn, Coral Gables, FL 33136 USA
来源
TRANSLATIONAL VISION SCIENCE & TECHNOLOGY | 2019年 / 8卷 / 03期
关键词
OCT imaging; segmentation; corneal microlayers; IN-VIVO CHARACTERISTICS; TOPOGRAPHIC THICKNESS; DIAGNOSIS; MEMBRANE; LAYER; OCT;
D O I
10.1167/tvst.8.3.39
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To propose automatic segmentation algorithm (AUS) for corneal microlayers on optical coherence tomography (OCT) images. Methods: Eighty-two corneal OCT scans were obtained from 45 patients with normal and abnormal corneas. Three testing data sets totaling 75 OCT images were randomly selected. Initially, corneal epithelium and endothelium microlayers are estimated using a corneal mask and locally refined to obtain final segmentation. Flat-epithelium and flat-endothelium images are obtained and vertically projected to locate inner corneal microlayers. Inner microlayers are estimated by translating epithelium and endothelium microlayers to detected locations then refined to obtain final segmentation. Images were segmented by trained manual operators (TMOs) and by the algorithm to assess repeatability (i.e., intraoperator error), reproducibility (i.e., interoperator and segmentation errors), and running time. A random masked subjective test was conducted by corneal specialists to subjectively grade the segmentation algorithm. Results: Compared with the TMOs, the AUS had significantly less mean intraoperator error (0.53 +/- 1.80 vs. 2.32 +/- 2.39 pixels; P < 0.0001), it had significantly different mean segmentation error (3.44 +/- 3.46 vs. 2.93 +/- 3.02 pixels; P < 0.0001), and it had significantly less running time per image (0.19 +/- 0.07 vs. 193.95 +/- 194.53 seconds; P < 0.0001). The AUS had insignificant subjective grading for microlayer-segmentation grading (4.94 +/- 032 vs. 4.96 +/- 0.24; P = 0.5081), but it had significant subjective grading for regional-segmentation grading (4.96 +/- 0.26 vs. 4.79 +/- 0.60; P = 0.025). Conclusions: The AUS can reproduce the manual segmentation of corneal microlayers with comparable accuracy in almost real-time and with significantly better repeatability. Translational Relevance: The AUS can be useful in clinical settings and can aid the diagnosis of corneal diseases by measuring thickness of segmented corneal microlayers.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Active contour detection for the segmentation of optical coherence tomography images of the retina
    Somfai, Gabor Mark
    Jozsef, Molnar
    Chetverikov, Dmitry
    DeBuc, Delia
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [32] Vessel segmentation in 2-D optical coherence tomography images
    Liu, Li-chang
    Lee, Jiann-der
    Hsu, Yu-wei
    Tseng, Scott
    Tseng, Ellen
    Tsai, Meng-tsan
    2013 ICME INTERNATIONAL CONFERENCE ON COMPLEX MEDICAL ENGINEERING (CME), 2013, : 35 - 39
  • [33] Global-Local Transformer Network for Automatic Retinal Pathological Fluid Segmentation in Optical Coherence Tomography Images
    Li, Feng
    Wei, Hao
    Sheng, Xinyu
    Chen, Yuyang
    Zou, Haidong
    Huang, Song
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2025, 266
  • [34] Region segmentation in 3-D optical coherence tomography images
    Chou, Cheng-wei
    Lee, Jiann-der
    Liu, Carol T.
    Tsai, Meng-tsan
    2014 IEEE INTERNATIONAL SYMPOSIUM ON BIOELECTRONICS AND BIOINFORMATICS (ISBB), 2014,
  • [35] Mathematical analysis of texture indicators for the segmentation of optical coherence tomography images
    Monemian, Maryam
    Rabbani, Hossein
    OPTIK, 2020, 219
  • [36] Convolution neural networks and support vector machines for automatic segmentation of intracoronary optical coherence tomography
    Zhang C.
    Li H.
    Guo X.
    Molony D.
    Guo X.
    Samady H.
    Giddens D.P.
    Athanasiou L.
    Nie R.
    Cao J.
    Tang D.
    MCB Molecular and Cellular Biomechanics, 2019, 16 (02): : 153 - 161
  • [37] Corneal dystrophies in optical coherence tomography
    Elhardt, C.
    Priglinger, S. G.
    Karakolova, Y.
    Mayer, W. J.
    Wertheimer, C.
    OPHTHALMOLOGE, 2019, 116 (09): : 857 - 864
  • [38] Automatic Segmentation of the Central Epithelium Imaged With Three Optical Coherence Tomography Devices
    Ge, Lili
    Shen, Meixiao
    Tao, Aizhu
    Wang, Jianhua
    Dou, Guopeng
    Lu, Fan
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2012, 38 (03): : 150 - 157
  • [39] Automatic classification and segmentation of atherosclerotic plaques in the intravascular optical coherence tomography (IVOCT)
    Tang, Hui
    Zhang, Zhenquan
    He, Yanglong
    Shen, Jinhua
    Zheng, Jin
    Gao, Wei
    Sadat, Umar
    Wang, Mingxin
    Wang, Yupeng
    Ji, Xu
    Chen, Yang
    Teng, Zhongzhao
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2023, 85
  • [40] Choroid automatic segmentation and thickness quantification on swept-source optical coherence tomography images of highly myopic patients
    Li, Menghan
    Zou, Haidong
    He, Jiangnan
    Zhu, Jianfeng
    Chen, Xinjian
    Shi, Fei
    Fan, Ying
    Xu, Xun
    ANNALS OF TRANSLATIONAL MEDICINE, 2022, 10 (11)