Automatic Segmentation of Corneal Microlayers on Optical Coherence Tomography Images

被引:14
|
作者
Elsawy, Amr [1 ,2 ]
Abdel-Mottaleb, Mohamed [2 ]
Sayed, Ibrahim-Osama [1 ]
Wen, Dan [1 ]
Roongpoovapatr, Vatookarn [1 ]
Eleiwa, Taher [1 ,3 ]
Sayed, Ahmed M. [1 ,4 ]
Raheem, Mariam [1 ]
Gameiro, Gustavo [1 ]
Abou Shousha, Mohamed [1 ,2 ,5 ]
机构
[1] Univ Miami, Miller Sch Med, Bascom Palmer Eye Inst, 900 Northwest 17th St, Miami, FL 33136 USA
[2] Univ Miami, Elect & Comp Engn, Coral Gables, FL 33136 USA
[3] Benha Fac Med, Ophthalmol Dept, Banha, Egypt
[4] Helwan Univ, Fac Engn, Biomed Engn Dept, Helwan, Egypt
[5] Univ Miami, Biomed Engn, Coral Gables, FL 33136 USA
来源
TRANSLATIONAL VISION SCIENCE & TECHNOLOGY | 2019年 / 8卷 / 03期
关键词
OCT imaging; segmentation; corneal microlayers; IN-VIVO CHARACTERISTICS; TOPOGRAPHIC THICKNESS; DIAGNOSIS; MEMBRANE; LAYER; OCT;
D O I
10.1167/tvst.8.3.39
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To propose automatic segmentation algorithm (AUS) for corneal microlayers on optical coherence tomography (OCT) images. Methods: Eighty-two corneal OCT scans were obtained from 45 patients with normal and abnormal corneas. Three testing data sets totaling 75 OCT images were randomly selected. Initially, corneal epithelium and endothelium microlayers are estimated using a corneal mask and locally refined to obtain final segmentation. Flat-epithelium and flat-endothelium images are obtained and vertically projected to locate inner corneal microlayers. Inner microlayers are estimated by translating epithelium and endothelium microlayers to detected locations then refined to obtain final segmentation. Images were segmented by trained manual operators (TMOs) and by the algorithm to assess repeatability (i.e., intraoperator error), reproducibility (i.e., interoperator and segmentation errors), and running time. A random masked subjective test was conducted by corneal specialists to subjectively grade the segmentation algorithm. Results: Compared with the TMOs, the AUS had significantly less mean intraoperator error (0.53 +/- 1.80 vs. 2.32 +/- 2.39 pixels; P < 0.0001), it had significantly different mean segmentation error (3.44 +/- 3.46 vs. 2.93 +/- 3.02 pixels; P < 0.0001), and it had significantly less running time per image (0.19 +/- 0.07 vs. 193.95 +/- 194.53 seconds; P < 0.0001). The AUS had insignificant subjective grading for microlayer-segmentation grading (4.94 +/- 032 vs. 4.96 +/- 0.24; P = 0.5081), but it had significant subjective grading for regional-segmentation grading (4.96 +/- 0.26 vs. 4.79 +/- 0.60; P = 0.025). Conclusions: The AUS can reproduce the manual segmentation of corneal microlayers with comparable accuracy in almost real-time and with significantly better repeatability. Translational Relevance: The AUS can be useful in clinical settings and can aid the diagnosis of corneal diseases by measuring thickness of segmented corneal microlayers.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Automatic Annotation of Retinal Layers in Optical Coherence Tomography Images
    Dodo, Bashir Isa
    Li, Yongmin
    Eltayef, Khalid
    Liu, Xiaohui
    JOURNAL OF MEDICAL SYSTEMS, 2019, 43 (12)
  • [22] Graph Based Lumen Segmentation in Optical Coherence Tomography Images
    Xu, Mengdi
    Cheng, Jun
    Wong, Damon Wing Kee
    Liu, Jiang
    Taruya, Akira
    Tanaka, Atsushi
    2015 10TH INTERNATIONAL CONFERENCE ON INFORMATION, COMMUNICATIONS AND SIGNAL PROCESSING (ICICS), 2015,
  • [23] Automatic Identification of Macular Edema in Optical Coherence Tomography Images
    Samagaio, Gabriela
    Estevez, Aida
    de Moura, Joaquim
    Novo, Jorge
    Ortega, Marcos
    Isabel Fernandez, Maria
    VISAPP: PROCEEDINGS OF THE 13TH INTERNATIONAL JOINT CONFERENCE ON COMPUTER VISION, IMAGING AND COMPUTER GRAPHICS THEORY AND APPLICATIONS - VOL 4: VISAPP, 2018, : 533 - 540
  • [24] Corneal layer thickness in keratoconus using optical coherence tomography
    Heidari, Zahra
    Mohammadpour, Mehrdad
    Hajizadeh, Fedra
    Fotouhi, Akbar
    Hashemi, Hassan
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2024, 107 (01) : 32 - 39
  • [25] An unsupervised hierarchical approach for automatic intra-retinal cyst segmentation in spectral-domain optical coherence tomography images
    Ganjee, Razieh
    Moghaddam, Mohsen Ebrahimi
    Nourinia, Ramin
    MEDICAL PHYSICS, 2020, 47 (10) : 4872 - 4884
  • [26] Automatic detection of tooth cracks in optical coherence tomography images
    Kim, Jun-Min
    Kang, Se-Ryong
    Yi, Won-Jin
    JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2017, 47 (01) : 41 - 50
  • [27] Automatic intraocular lens segmentation and detection in optical coherence tomography imagese
    Gillner, Melanie
    Eppig, Timo
    Langenbucher, Achim
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2014, 24 (02): : 104 - 111
  • [28] Evaluation of segmentation algorithms for optical coherence tomography images of ovarian tissue
    Sawyer, Travis W.
    Rice, Photini F. S.
    Sawyer, David M.
    Koevary, Jennifer W.
    Barton, Jennifer K.
    DIAGNOSIS AND TREATMENT OF DISEASES IN THE BREAST AND REPRODUCTIVE SYSTEM IV, 2018, 10472
  • [29] Intra-retinal layer segmentation in optical coherence tomography images
    Mishra, Akshaya
    Wong, Alexander
    Bizheva, Kostadinka
    Clausi, David A.
    OPTICS EXPRESS, 2009, 17 (26): : 23719 - 23728
  • [30] Fast detection and segmentation of drusen in retinal optical coherence tomography images
    Farsiu, Sina
    Chiu, Stephanie J.
    Izatt, Joseph A.
    Toth, Cynthia A.
    OPHTHALMIC TECHNOLOGIES XVIII, 2008, 6844