摘要
A comparative study is reported where folic acid (FA) and boronic acid (BA) based cytosensors and their analytical performances in cancer cell detection were analyzed by using electrochemical impedance spectroscopy (EIS) method. Cytosensors were fabricated using self -assembled monolayer principle by modifying Au electrode with cysteamine (Cys) and immobilization of ferrocene cored polyamidiamine dendrimers second generation (Fc-PAMAM (G2)), after which electrodes were modified with FA and BA. Au/Fc-PAMAM(G2)/FA and Au/Fc-PAMAM(G2)/BA based cytosensors showed extremely good analytical performances in cancer cell detection with linear range of 1 x10(2) to 1 x10(6) cells ml(-1), detection limit of 20 cells ml(-1) with incubation time of 20 min for FA based electrode, and for BA based electrode detection limit was 28 cells ml(-1) with incubation time of 10 min. Next to excellent analytical performances, cytosensors showed high selectivity towards cancer cells which was demonstrated in selectivity study using human embryonic kidney 293 cells (HEK 293) as normal cells and Au/Fc-PAMAM(G2)/FA electrode showed two times better selectivity than BA modified electrode. These cytosensors are promising for future applications in cancer cell diagnosis.
引用
收藏
页码:680 / 686
页数:7
相关论文
共 53 条
[31]   Highly sensitive and selective detection of cancer cell with a label-free electrochemical cytosensor [J].
Liu, Jiyang ;
Qin, Yinan ;
Li, Dan ;
Wang, Tianshu ;
Liu, Yaqing ;
Wang, Jin ;
Wang, Erkang .
BIOSENSORS & BIOELECTRONICS, 2013, 41 :436-441
[32]  
Lu MH, 2015, INT J CLIN EXP MED, V8, P7830
[33]  
Marcos NT, 2008, J CLIN INVEST, V118, P2325, DOI [10.1172/JC134324, 10.1172/JCI34324]
[34]   Immobilization free electrochemical biosensor for folate receptor in cancer cells based on terminal protection [J].
Ni, Jiancong ;
Wang, Qingxiang ;
Yang, Weiqiang ;
Zhao, Mengmeng ;
Zhang, Ying ;
Guo, Longhua ;
Qiu, Bin ;
Lin, Zhenyu ;
Yang, Huang-Hao .
BIOSENSORS & BIOELECTRONICS, 2016, 86 :496-501
[35]   Introducing a new method for evaluation of the interaction between an antigen and an antibody: Single frequency impedance analysis for biosensing systems [J].
Ozcan, Burcu ;
Demirbakan, Burcak ;
Yesiller, Gulden ;
Sezginturk, Mustafa Kemal .
TALANTA, 2014, 125 :7-13
[36]   Flow cytometric analysis of cell-surface and intracellular antigens in the diagnosis of acute leukemia [J].
Paredes-Aguilera, R ;
Romero-Guzman, L ;
Lopez-Santiago, N ;
Burbano-Ceron, L ;
Camacho-Del Monte, O ;
Nieto-Martinez, S .
AMERICAN JOURNAL OF HEMATOLOGY, 2001, 68 (02) :69-74
[37]   Expanding roles for organoboron compounds - Versatile and valuable molecules for synthetic, biological, and medicinal chemistry [J].
Petasis, Nicos A. .
AUSTRALIAN JOURNAL OF CHEMISTRY, 2007, 60 (11) :795-798
[38]   Detection of circulating epithelial cells in the blood of patients with breast cancer: comparison of three techniques [J].
Ring, AE ;
Zabaglo, L ;
Ormerod, MG ;
Smith, IE ;
Dowsett, M .
BRITISH JOURNAL OF CANCER, 2005, 92 (05) :906-912
[39]  
ROSS JF, 1994, CANCER-AM CANCER SOC, V73, P2432, DOI 10.1002/1097-0142(19940501)73:9<2432::AID-CNCR2820730929>3.0.CO
[40]  
2-S