Temperature dependant relaxation studies on oil-filled transformer

被引:9
作者
Cao, HY [1 ]
Birlasekaran, S [1 ]
机构
[1] Nanyang Technol Univ, Sch EEE, Singapore 639798, Singapore
来源
CONFERENCE RECORD OF THE 2002 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION | 2002年
关键词
D O I
10.1109/ELINSL.2002.995906
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Relaxation studies in oil-filled transformer are very important to evaluate the ageing characteristics of oil-paper insulated transformer. The polarization processes at the interfaces can be understood by making measurements at different operating temperatures. A laboratory study is carried out by both frequency and time domain techniques. In the frequency domain technique, a dielectrometer is used and the linear response characteristics with energizing voltage magnitude up to 200V peak are studied. In the time domain method, recovery voltage method (RVM) up to 300V dc is used to study the linearity in response. The obtained response is fitted to extended Debye model and interrelation of model with each measuring technique is established. Then, the temperature dependence of these parameters is studied by keeping the oil-paper insulated transformer in a humidity/temperature controller for 10 hours with a setting. The ambient temperature is changed from 20degreesC to 50degreesC. The responses at high temperatures differ from the measurement at room temperature. The conductance property of the transformer insulation between two windings changes significantly. Three types of analysis are done to correlate the measurements. The first analysis is to fit the frequency and time domain responses to extended Debye model. The determined parameters are compared to evaluate the validity of model. In the second method of analysis with RVM, RV spectra are evaluated in term of peak magnitude variation and time shift of peak occurrence with temperature. In the third method of analysis with low frequency response, it is found that the variation of admittance and loss angle has a unique bandwidth variation with temperature. It is found that the relaxation processes of oil and oil-paper are distinctive and their dependence on temperature is different.
引用
收藏
页码:174 / 178
页数:5
相关论文
共 5 条
[1]   Moisture solubility for differently conditioned transformer oils [J].
Du, Y ;
Mamishev, AV ;
Lesieutre, BC ;
Zahn, M ;
Kang, SH .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2001, 8 (05) :805-811
[2]   Moisture equilibrium in transformer paper-oil systems [J].
Du, Y ;
Zahn, M ;
Lesieutre, BC ;
Mamishev, AV ;
Lindgren, SR .
IEEE ELECTRICAL INSULATION MAGAZINE, 1999, 15 (01) :11-20
[3]  
JODA PRS, 1999, IEEE T DIELECTRIC EL, V6
[4]  
KASAP SO, 1997, PRINCIPLES ELECT ENG, P534
[5]  
2000, IDA 200 INSULATION D