Electrospray ionization mass spectrometry and partial least squares discriminant analysis applied to the quality control of olive oil

被引:19
|
作者
Alves, Junia O. [1 ]
Botelho, Bruno G. [1 ]
Sena, Marcelo M. [1 ]
Augusti, Rodinei [1 ]
机构
[1] Univ Fed Minas Gerais, Dept Quim, ICEx, BR-31270901 Belo Horizonte, MG, Brazil
来源
JOURNAL OF MASS SPECTROMETRY | 2013年 / 48卷 / 10期
关键词
olive oil authentication; extra virgin olive oil; ordinary olive oil; edible oils; adulteration; ESI-MS; PLS-DA; VEGETABLE-OILS; ADULTERATION; IDENTIFICATION; SPECTROSCOPY; AUTHENTICITY; PROFILES; BLENDS; ORIGIN; MS;
D O I
10.1002/jms.3256
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Direct infusion electrospray ionization mass spectrometry in the positive ion mode [ESI(+)-MS] is used to obtain fingerprints of aqueous-methanolic extracts of two types of olive oils, extra virgin (EV) and ordinary (OR), as well as of samples of EV olive oil adulterated by the addition of OR olive oil and other edible oils: corn (CO), sunflower (SF), soybean (SO) and canola (CA). The MS data is treated by the partial least squares discriminant analysis (PLS-DA) protocol aiming at discriminating the above-mentioned classes formed by the genuine olive oils, EV (1) and OR (2), as well as the EV adulterated samples, i.e. EV/SO (3), EV/CO (4), EV/SF (5), EV/CA (6) and EV/OR (7). The PLS-DA model employed is built with 190 and 70 samples for the training and test sets, respectively. For all classes (1-7), EV and OR olive oils as well as the adulterated samples (in a proportion varying from 0.5 to 20.0% w/w) are properly classified. The developed methodology required no ions identification and demonstrated to be fast, as each measurement lasted about 3 min including the extraction step and MS analysis, and reliable, because high sensitivities (rate of true positives) and specificities (rate of true negatives) were achieved. Finally, it can be envisaged that this approach has potential to be applied in quality control of EV olive oils. Copyright (C) 2013 John Wiley & Sons, Ltd. Supporting information may be found in the online version of this article.
引用
收藏
页码:1109 / 1115
页数:7
相关论文
共 50 条
  • [31] Analysis of black writing ink by electrospray ionization mass spectrometry
    Williams, Mary R.
    Moody, Chris
    Arceneaux, Lei-Ann
    Rinke, Caitlin
    White, Katie
    Sigman, Michael E.
    FORENSIC SCIENCE INTERNATIONAL, 2009, 191 (1-3) : 97 - 103
  • [32] Sodium Cationization Electrospray Ionization Orbitrap Mass Spectrometry for Selective Determination of Crude Oil Porphyrins
    Nyadong, Leonard
    Mendez-Arroyo, Jose
    ENERGY & FUELS, 2021, 35 (22) : 18116 - 18124
  • [33] Multivariate calibration applied to ESI mass spectrometry data: a tool to quantify adulteration in extra virgin olive oil with inexpensive edible oils
    Alves, J. O.
    Sena, M. M.
    Augusti, R.
    ANALYTICAL METHODS, 2014, 6 (18) : 7502 - 7509
  • [34] Quantitative analysis of positional isomers of triacylglycerols via electrospray ionization tandem mass spectrometry of sodiated adducts
    Herrera, Lisandra Cubero
    Potvin, Michael A.
    Melanson, Jeremy E.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2010, 24 (18) : 2745 - 2752
  • [35] Direct infusion electrospray ionisation mass spectrometry applied in the detection of adulteration of coconut oil with palm kernel oil
    Pizzo, Jessica Santos
    Galuch, Marilia Bellanda
    Manin, Luciana Pelissari
    Silva Santos, Patricia Daniele
    Zappielo, Caroline Delivio
    Santos Junior, Oscar
    Visentainer, Jesui Vergilio
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2019, 36 (11): : 1597 - 1604
  • [36] The quantitative surface analysis of an antioxidant additive in a lubricant oil matrix by desorption electrospray ionization mass spectrometry
    Da Costa, Caitlyn
    Reynolds, James C.
    Whitmarsh, Samuel
    Lynch, Tom
    Creaser, Colin S.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2013, 27 (21) : 2420 - 2424
  • [37] Efficient and Simplified Modeling for Kerosene Processing Quality Detection Using Partial Least Squares-Discriminant Analysis Regression
    Issa, Hayder M.
    Salih, Rezan H. Hama
    ARO-THE SCIENTIFIC JOURNAL OF KOYA UNIVERSITY, 2024, 12 (01): : 135 - 142
  • [38] Discrimination of Human and Nonhuman Blood by Raman Spectroscopy and Partial Least Squares Discriminant Analysis
    Bai, Pengli
    Wang, Jun
    Yin, Huancai
    Tian, Yubing
    Yao, Wenming
    Gao, Jing
    ANALYTICAL LETTERS, 2017, 50 (02) : 379 - 388
  • [39] Generating Supercharged Protein Ions for Breath Analysis by Extractive Electrospray Ionization Mass Spectrometry
    Ke, Mufang
    Zhang, Hua
    Ding, Jianhua
    Xiong, Xingchuang
    Li, Fenglei
    Chingin, Konstantin
    Kou, Wei
    Liu, Aiying
    Zhu, Tenggao
    Fang, Xiang
    Chen, Huanwen
    ANALYTICAL CHEMISTRY, 2019, 91 (05) : 3215 - 3220
  • [40] Differential analysis of human kidney stone samples using electrospray ionization mass spectrometry
    Zhou, Zhiquan
    Ouyang, Yongzhong
    Zeng, Xiangtai
    Zhang, Tingting
    Jia, Bin
    Zhang, Xinglei
    Chen, Huanwen
    Ding, Jianhua
    AFRICAN JOURNAL OF PHARMACY AND PHARMACOLOGY, 2011, 5 (17): : 2018 - 2026