Micromachined thin film solid state electrochemical CO2, NO2 and SO2 gas sensors

被引:71
|
作者
Currie, JF
Essalik, A
Marusic, JC
机构
[1] Georgetown Univ, Dept Phys, Georgetown Adv Elect Lab, Washington, DC 20057 USA
[2] Ecole Polytech, Dept Engn Phys, Lab Integrat Sensors & Actuators, Montreal, PQ H3C 3A7, Canada
关键词
thin film; electrochemical; gas sensor; material characterization; performance; air pollution;
D O I
10.1016/S0925-4005(99)00227-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Among the many physical and chemical strategies used to make air pollution gas sensors for COx, NOx, SOx monitoring, those employing electrochemical detection means offer the highest selectivity, long lifetimes, low drift and low costs of manufacture. Targeting the three gases CO2, NO2 and SO2, new solid-electrolyte-based, selective potentiometric gas sensors were fabricated in both bulk and thin film versions. For all six bulk and thin film sensors, the EMF responses were related to the analyzed target gas pressure by the Nernst law. For each of the target gases CO2, NO2 and SO2, our thin film micro-sensor exhibits excellent gas-sensing sensitivity, response time, selectivity and recovery compared to the bulk sensor. The carbon dioxide micro-sensor characteristics obtained at 250 degrees C were 45 +/- 3 mV/decade for the sensitivity, 10 to 30 s for the response time and 60 s for recovery time. The nitrogen dioxide micro-sensor characteristics obtained at 200 degrees C were 48 +/- 3 mV/decade for the sensitivity, 2 to 10 s for the response time and 10 s for recovery time. The sulfur dioxide micro-sensor characteristics obtained at 250 degrees C were 50 +/- 3 mV/decade for the sensitivity, 1 to 2 s for the response time and 5 s for recovery time. In comparison, the bulk sensor CO2 characteristics obtained at 250 degrees C were 50 +/- 3 mV/decade for the sensitivity, 60 to 300 s for the response time and 900 s for recovery time. To verify selectivity in air samples, the sensitivity of each gas detector with respect to the gases CO2, NO2 and SO2, oxygen, CO, and humidity were evaluated. The CO2 sensor was insensitive to the later three gases, but there was a measurable EMF drift produced for NO2 at concentrations above 10 ppm and for SO2 at concentrations above 80 ppm. Similarly, the NO2 sensor operating at 200 degrees C was insensitive to all other gases except for SO2 at concentrations above 80 ppm. Finally, the SO2 sensor operating at 250 degrees C was insensitive to all other. We optimized our processing to obtain a dense strongly adhering deposited solid electrolyte thin film. XPS and XRD studies show that the chemical composition and structure of the deposited solid electrolyte thin-film and targets for RF magnetron sputtering were the same to within experimental error. For brevity, complete results are presented only for the CO2 micro-sensor. The results for the other two gas micro-sensors are essentially the same and will be published elsewhere. (C) 1999 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:235 / 241
页数:7
相关论文
共 50 条
  • [1] Study of thin-film SO2 gas sensors by photometric and ellipsometric methods
    Tang, ZS
    Fan, ZX
    Shao, JD
    OPTICAL ENGINEERING, 2001, 40 (05) : 856 - 860
  • [2] Miniaturized solid state electrochemical CO2 sensors
    Steudel, E
    Birke, P
    Weppner, W
    ELECTROCHIMICA ACTA, 1997, 42 (20-22) : 3147 - 3153
  • [3] Calibration of SO2 and NO2 Electrochemical Sensors via a Training and Testing Method in an Industrial Coastal Environment
    Ahumada, Sofia
    Tagle, Matias
    Vasquez, Yeanice
    Donoso, Rodrigo
    Linden, Jenny
    Hallgren, Fredrik
    Segura, Marta
    Oyola, Pedro
    SENSORS, 2022, 22 (19)
  • [4] NO2 Gas Sensing Performance of Co-Doped NiO Thin Film Sensors
    Park, Sunghoon
    Kim, Soohyun
    Sun, Gun-Joo
    Lee, Chongmu
    NANOSCIENCE AND NANOTECHNOLOGY LETTERS, 2015, 7 (09) : 713 - 717
  • [5] Recent Advances in Electrochemical Sensors for Detecting Toxic Gases: NO2, SO2 and H2S
    Khan, Md Ashfaque Hossain
    Rao, Mulpuri V.
    Li, Qiliang
    SENSORS, 2019, 19 (04)
  • [6] Amperometric SO2 gas sensors based on solid polymer electrolytes
    Chiou, CY
    Chou, TC
    SENSORS AND ACTUATORS B-CHEMICAL, 2002, 87 (01) : 1 - 7
  • [7] Density functional study of adsorptions of CO2, NO2 and SO2 molecules on Zn(0002) surfaces
    Nugraha
    Saputro, A. G.
    Agusta, M. K.
    Yuliarto, B.
    Dipojono, H. K.
    Maezono, R.
    6TH ASIAN PHYSICS SYMPOSIUM, 2016, 739
  • [8] THE PAST, PRESENT AND FUTURE OF CO2, NO2, SO2 & CH4 IN PUNJAB REGION, INDIA
    Romana, H. K.
    Shukla, D. P.
    XXIV ISPRS CONGRESS: IMAGING TODAY, FORESEEING TOMORROW, COMMISSION III, 2022, 43-B3 : 743 - 748
  • [9] Influence of CO2 gas on the rate and kinetics of HCl, SO2, and NO2 gas removal by Mg-Al layered double hydroxide intercalated with CO32-
    Kameda, Tomohito
    Uchida, Hiroki
    Kumagai, Shogo
    Saito, Yuko
    Mizushina, Keiichi
    Itou, Ichirou
    Han, Tianye
    Yoshioka, Toshiaki
    APPLIED CLAY SCIENCE, 2020, 195
  • [10] CO2 and SO2 Interactions with Methylated Poly(ethylenimine)-Functionalized Capacitive Micromachined Ultrasonic Transducers (CMUTs): Gas Sensing and Degradation Mechanism
    Barauskas, Dovydas
    Park, Sang Jae
    Pelenis, Donatas
    Vanagas, Gailius
    Lee, Jason J.
    Virzonis, Darius
    Jones, Christopher W.
    Baltrusaitis, Jonas
    ACS APPLIED ELECTRONIC MATERIALS, 2019, 1 (07) : 1150 - 1161