Camera-based photoplethysmography in an intraoperative setting

被引:26
作者
Trumpp, Alexander [1 ]
Lohr, Johannes [2 ]
Wedekind, Daniel [1 ]
Schmidt, Martin [1 ]
Burghardt, Matthias [2 ]
Heller, Axel R. [2 ]
Malberg, Hagen [1 ]
Zaunseder, Sebastian [1 ]
机构
[1] Tech Univ Dresden, Inst Biomed Engn, Fetscherstr 29, D-01307 Dresden, Germany
[2] Tech Univ Dresden, Univ Hosp, Dept Anesthesiol & Intens Care Med, Fetscherstr 74, D-01307 Dresden, Germany
关键词
Camera-based photoplethysmography; Intraoperative monitoring; Remote monitoring; Level set methods; Spatial homogeneity; HEART-RATE; OXYGEN-SATURATION; AMBIENT LIGHT; NONCONTACT; PPG; PERFUSION; SIGNALS; RPPG;
D O I
10.1186/s12938-018-0467-7
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Camera-based photoplethysmography (cbPPG) is a measurement technique which enables remote vital sign monitoring by using cameras. To obtain valid plethysmograms, proper regions of interest (ROIs) have to be selected in the video data. Most automated selection methods rely on specific spatial or temporal features limiting a broader application. In this work, we present a new method which overcomes those drawbacks and, therefore, allows cbPPG to be applied in an intraoperative environment. Methods: We recorded 41 patients during surgery using an RGB and a near-infrared (NIR) camera. A Bayesian skin classifier was employed to detect suitable regions, and a level set segmentation approach to define and track ROIs based on spatial homogeneity. Results: The results show stable and homogeneously illuminated ROIs. We further evaluated their quality with regards to extracted cbPPG signals. The green channel provided the best results where heart rates could be correctly estimated in 95.6% of cases. The NIR channel yielded the highest contribution in compensating false estimations. Conclusions: The proposed method proved that cbPPG is applicable in intraoperative environments. It can be easily transferred to other settings regardless of which body site is considered.
引用
收藏
页数:19
相关论文
共 43 条
[1]   Photoplethysmography and its application in clinical physiological measurement [J].
Allen, John .
PHYSIOLOGICAL MEASUREMENT, 2007, 28 (03) :R1-R39
[2]   Spectral-spatial fusion model for robust blood pulse waveform extraction in photoplethysmographic imaging [J].
Amelard, Robert ;
Clausi, David A. ;
Wong, Alexander .
BIOMEDICAL OPTICS EXPRESS, 2016, 7 (12) :4874-4885
[3]  
[Anonymous], 2017, BILDVERARBEITUNG MED, DOI DOI 10.1007/978-3-662-54345-0_16
[4]   Non-contact estimation of heart rate and oxygen saturation using ambient light [J].
Bal, Ufuk .
BIOMEDICAL OPTICS EXPRESS, 2015, 6 (01) :86-97
[5]   Peripheral vasomotor activity assessment using a continuous wavelet analysis on webcam photoplethysmographic signals [J].
Bousefsaf, F. ;
Maaoui, C. ;
Pruski, A. .
BIO-MEDICAL MATERIALS AND ENGINEERING, 2016, 27 (05) :527-538
[6]   Automatic Selection of Webcam Photoplethysmographic Pixels Based on Lightness Criteria [J].
Bousefsaf, Frederic ;
Maaoui, Choubeila ;
Pruski, Alain .
JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2017, 37 (03) :374-385
[7]   Continuous wavelet filtering on webcam photoplethysmographic signals to remotely assess the instantaneous heart rate [J].
Bousefsaf, Frederic ;
Maaoui, Choubeila ;
Pruski, Alain .
BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2013, 8 (06) :568-574
[8]   Colour, texture, and motion in level set based segmentation and tracking [J].
Brox, Thomas ;
Rousson, Mikael ;
Deriche, Rachid ;
Weickert, Joachim .
IMAGE AND VISION COMPUTING, 2010, 28 (03) :376-390
[9]   Motion limitations of non-contact photoplethysmography due to the optical and topological properties of skin [J].
Butler, M. J. ;
Crowe, J. A. ;
Hayes-Gill, B. R. ;
Rodmell, P. I. .
PHYSIOLOGICAL MEASUREMENT, 2016, 37 (05) :N27-N37
[10]   Optimal wavelength selection for non-contact reflection photoplethysmography [J].
Corral, Luis F. ;
Paez, Gonzalo ;
Strojnik, Marija .
22ND CONGRESS OF THE INTERNATIONAL COMMISSION FOR OPTICS: LIGHT FOR THE DEVELOPMENT OF THE WORLD, 2011, 8011