Squeaking and other noises in patients with ceramic-on-ceramic total hip arthroplasty

被引:5
作者
Baruffaldi, Fabio [1 ]
Mecca, Rosaria [1 ]
Stea, Susanna [1 ]
Beraudi, Alina [1 ]
Bordini, Barbara [1 ]
Amabile, Marilina [1 ]
Sudanese, Alessandra [2 ]
Toni, Aldo [2 ]
机构
[1] IRCCS Ist Ortoped Rizzoli, Lab Med Technol, Via Barbiano 1-10, I-40136 Bologna, Italy
[2] IRCCS Ist Ortoped Rizzoli, Orthopaed Traumatol & Prosthet Surg & Revis Hip &, Bologna, Italy
关键词
Ceramic-on-ceramic bearing; noise; squeaking; total hip arthroplasty; EARLY-DIAGNOSIS; ACETABULAR CUP; STEM DESIGN; IN-VITRO; PREVALENCE; ALUMINA; METAL;
D O I
10.1177/1120700019864233
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Noise in ceramic-on-ceramic (CoC) total hip arthroplasty (THA) is a potential symptom of abnormal bearing wear. Squeaking and other prosthetic hip noises are multi-factorial phenomena that can be analysed and may provide prognostic information. Methods: 46 patients with noisy CoC bearings were investigated using X-ray, computed tomography and joint fluid analysis, and classified into either high or low risk of ceramic liner fracture groups according to previously published guidelines. Noise events from the bearings of 16 high risk cases which were subsequently revised were compared with 30 patients in the low risk control group who did not undergo revision. Noise events were analysed for their physical characteristics using a standardised protocol and classified as either low frequency and short duration 'clicking' or long duration and high frequency 'squeaking'. Results: The peak frequency of squeaking during forward walking was significantly higher for patients in the case group who were revised, compared with the control group. The patient-reported onset of squeaking (46 months postoperatively) was earlier than short-noise emissions (82 months). In the standardised sequence of movements, short-noise always occurred more frequently than squeaking. Small heads (28 mm) were more likely to develop short-noise, while large heads (> 32 mm) were more likely to develop squeaking. Discussion: Noise evaluation may provide additional value for predicting failure of CoC bearings, though some questions should be better investigated in a dedicated prospective trial.
引用
收藏
页码:438 / 445
页数:8
相关论文
共 32 条
  • [1] Is Ceramic-On-Ceramic Squeaking Phenomenon Reproducible In Vitro? A Long-Term Simulator Study Under Severe Conditions
    Affatato, S.
    Traina, F.
    Mazzega-Fabbro, C.
    Sergo, V.
    Viceconti, M.
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2009, 91B (01) : 264 - 271
  • [2] A Computational Analysis of Squeaking Hip Prostheses
    Askari, Ehsan
    Flores, Paulo
    Dabirrahmani, Dane
    Appleyard, Richard
    [J]. JOURNAL OF COMPUTATIONAL AND NONLINEAR DYNAMICS, 2015, 10 (02):
  • [3] Hip Squeaking A 10-Year Follow-Up Study
    Chevillotte, Christophe
    Pibarot, Vincent
    Carret, Jean-Paul
    Bejui-Hugues, Jacques
    Guyen, Olivier
    [J]. JOURNAL OF ARTHROPLASTY, 2012, 27 (06) : 1008 - 1013
  • [4] Incidence and Factors Associated with Squeaking in Alumina-on-Alumina THA
    Choi, Il-Yong
    Kim, Yee-Suk
    Hwang, Kyu-Tae
    Kim, Young-Ho
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (12) : 3234 - 3239
  • [5] The influence of stem design on critical squeaking friction with ceramic bearings
    Fan, Na
    Morlock, Michael M.
    Bishop, Nicholas E.
    Huber, Gerd
    Hoffmann, Norbert
    Ciavarella, Michele
    Chen, Guang X.
    Hothan, Arne
    Witt, Florian
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2013, 31 (10) : 1627 - 1632
  • [6] CT Outperforms Radiography for Determination of Acetabular Cup Version after THA
    Ghelman, Bernard
    Kepler, Christopher K.
    Lyman, Stephen
    Della Valle, Alejandro Gonzalez
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2009, 467 (09) : 2362 - 2370
  • [7] Clicking and Squeaking: In Vivo Correlation of Sound and Separation for Different Bearing Surfaces
    Glaser, Diana
    Komistek, Richard D.
    Cates, Harold E.
    Mahfouz, Mohamed R.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A : 112 - 120
  • [8] The influence of component design, bearing clearance and axial load on the squeaking characteristics of ceramic hip articulations
    Hothan, Arne
    Huber, Gerd
    Weiss, Cornelius
    Hoffmann, Norbert
    Morlock, Michael
    [J]. JOURNAL OF BIOMECHANICS, 2011, 44 (05) : 837 - 841
  • [9] Factors affecting squeaking in metal on metal hip resurfacings
    Imbuldeniya, Arjuna
    Munir, Selin
    Chow, Jason
    Walter, William L.
    Zicat, Bernard A.
    Walter, William K.
    [J]. HIP INTERNATIONAL, 2014, 24 (04) : 340 - 346
  • [10] Position of the acetabular cup - accuracy of radiographic calculation compared to CT-based measurement
    Kalteis, T
    Handel, M
    Herold, T
    Perlick, L
    Paetzel, C
    Grifka, J
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2006, 58 (02) : 294 - 300