Protocols for optimizing MS/MS parameters with an ion-trap GC-MS instrument

被引:11
|
作者
Beguin, Sylvie
Jadas-Hecart, Alain
Tabet, Jean-Claude
Communal, Pierre-Yves
机构
[1] UMR MA 105, Grp Interreg Rech Prod Agropharmaceut, F-49070 Beaucouze, France
[2] Univ Paris 06, Lab Chim Struct Organ & Biol, F-75252 Paris 05, France
来源
JOURNAL OF MASS SPECTROMETRY | 2006年 / 41卷 / 10期
关键词
pesticides; ion-trap GC/MS/MS instrument; q(z) stability parameter; CID efficiency; nonresonant excitation amplitude;
D O I
10.1002/jms.1102
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The product ion spectrum allows us to achieve very selective detection of pesticides and to eliminate the ambiguities caused by more conventional analytical approaches. Owing to the enhanced capabilities of GC/MS/MS for multiresidue pesticides, the development of a GCIMS/MS pesticides library will be useful. The aim of this study was to develop a sensitive and specific analytical method for the identification and quantification of compounds without the need of a time-consuming procedure. Two methods were studied in order to optimize the nonresonant conditions of dissociation of five pesticides (deltamethrin, metalaxyl, myclobutanil, procymidone, pirimicarb). The first permits a systematic investigation of the influence of the q(z) trapping parameter on sensitivity in precursor ion detection and on the efficiency of collision-induced dissociation (CID). The second is more suited for analytical laboratories and less time-consuming and allows us to reach similar results: the experiments were conducted step by step at a constant stability parameter. Copyright (c) 2006 John Wiley & Sons, Ltd.
引用
收藏
页码:1304 / 1314
页数:11
相关论文
共 50 条
  • [21] Ion trap GC-MS analysis of tissue samples for chlorinated compounds
    TX Parks Wildl. Environ. C., 505 Staples Road, San Marcos, TX 78666, United States
    ACS Symposium Series, 2001, 771 : 242 - 253
  • [22] Determination of pyrethroid insecticides by ion trap GC-MS-MS
    Bauerle, GF
    Ray, KL
    Brodbelt, JS
    ANALYTICA CHIMICA ACTA, 1995, 317 (1-3) : 137 - 148
  • [23] GC OR GC-MS
    PRATZEL, B
    STURINO, E
    POLLUTION ENGINEERING, 1983, 15 (08) : 28 - 29
  • [24] ECD-dual-column pesticide method verification by ion trap GC/MS and GC/MS/MS
    Pyle, SM
    Marcus, AB
    Robertson, GL
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1998, 32 (20) : 3213 - 3217
  • [25] LC-MS/MS AND GC-MS(/MS) BASED STEROIDOMICS
    Wudy, S. A.
    Sanchez-Guijo, A.
    Hartmann, M. F.
    REPRODUCTION IN DOMESTIC ANIMALS, 2014, 49 : 47 - 47
  • [26] GC-MS GC-MS/MS AND GC-IR STUDIES ON SUBSTITUTED CATHINONE DESIGNER DRUGS
    Clark, C. Randall
    Deruiter, Jack
    Abiedalla, Younis
    FORENSIC SCIENCE INTERNATIONAL, 2017, 277 : 75 - 75
  • [27] CHEMICAL-IONIZATION AND MS-MS TECHNOLOGIES FOR BENCHTOP ION-TRAP CC-MS SYSTEMS
    BRITTAIN, R
    FEIGEL, C
    AMERICAN LABORATORY, 1994, 26 (03) : 44 - &
  • [28] Identification of volatile compounds in sunflower oil by headspace SPME and ion-trap GC/MS
    Keszler, A
    Heberger, K
    Gude, M
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1998, 21 (06): : 368 - 370
  • [29] GC-MS AND GC-MS-MS ANALYSIS OF A COMPLEX ESSENTIAL OIL
    CAZAUSSUS, A
    PES, R
    SELLIER, N
    TABET, JC
    CHROMATOGRAPHIA, 1988, 25 (10) : 865 - 869
  • [30] GC-MS and GC-MS/MS measurement of the cardiovascular risk factor homoarginine in biological samples
    Kayacelebi, Arslan Arinc
    Beckmann, Bibiana
    Gutzki, Frank-Mathias
    Jordan, Jens
    Tsikas, Dimitrios
    AMINO ACIDS, 2014, 46 (09) : 2205 - 2217