Protocols for optimizing MS/MS parameters with an ion-trap GC-MS instrument

被引:11
|
作者
Beguin, Sylvie
Jadas-Hecart, Alain
Tabet, Jean-Claude
Communal, Pierre-Yves
机构
[1] UMR MA 105, Grp Interreg Rech Prod Agropharmaceut, F-49070 Beaucouze, France
[2] Univ Paris 06, Lab Chim Struct Organ & Biol, F-75252 Paris 05, France
来源
JOURNAL OF MASS SPECTROMETRY | 2006年 / 41卷 / 10期
关键词
pesticides; ion-trap GC/MS/MS instrument; q(z) stability parameter; CID efficiency; nonresonant excitation amplitude;
D O I
10.1002/jms.1102
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The product ion spectrum allows us to achieve very selective detection of pesticides and to eliminate the ambiguities caused by more conventional analytical approaches. Owing to the enhanced capabilities of GC/MS/MS for multiresidue pesticides, the development of a GCIMS/MS pesticides library will be useful. The aim of this study was to develop a sensitive and specific analytical method for the identification and quantification of compounds without the need of a time-consuming procedure. Two methods were studied in order to optimize the nonresonant conditions of dissociation of five pesticides (deltamethrin, metalaxyl, myclobutanil, procymidone, pirimicarb). The first permits a systematic investigation of the influence of the q(z) trapping parameter on sensitivity in precursor ion detection and on the efficiency of collision-induced dissociation (CID). The second is more suited for analytical laboratories and less time-consuming and allows us to reach similar results: the experiments were conducted step by step at a constant stability parameter. Copyright (c) 2006 John Wiley & Sons, Ltd.
引用
收藏
页码:1304 / 1314
页数:11
相关论文
共 50 条
  • [11] GC-MS and GC-MS/MS for the analysis of endogenous and exogenous hormones
    Martinchek, Justin
    Boylan, Helen M.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2005, 230 : U789 - U790
  • [12] Flying High with Sensitivity and Selectivity: GC-MS to GC-MS/MS
    Snow, Nicholas H.
    LC GC EUROPE, 2021, 34 (02) : 61 - 65
  • [13] TOF-MS and quadrupole ion-trap MS/MS for the discovery of herbicide degradates in groundwater
    Thurman, EM
    Ferrer, I
    Furlong, ET
    LIQUID CHROMATOGRAPHY/MASS SPECTROMETRY, MS/MS AND TIME-OF-FLIGHT MS, 2003, 850 : 128 - 144
  • [14] Improving ion-trap GC-MS quantitation limits for therapeutic agents extracted from rat plasma
    Kagel, JR
    Grove, CA
    Rossi, DT
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 16 (07) : 1261 - 1265
  • [15] Ion-trap MS aims to catch the wave
    不详
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2010, 29 (04) : V - V
  • [16] Application of ion-trap LC/MS/MS for determination of acrylamide in processed foods
    Tsutsumiuchi, K
    Hibino, M
    Kambe, M
    Oishi, K
    Okada, M
    Miwa, J
    Taniguchi, H
    JOURNAL OF THE FOOD HYGIENIC SOCIETY OF JAPAN, 2004, 45 (02): : 95 - 99
  • [17] Identification of trifluralin metabolites in soil using ion-trap LC/MS/MS
    Lerch, RN
    Ferrer, I
    Thurman, EM
    Zablotowicz, RM
    LIQUID CHROMATOGRAPHY/MASS SPECTROMETRY, MS/MS AND TIME-OF-FLIGHT MS, 2003, 850 : 291 - 310
  • [18] Analysis of furan fatty acids in dried green herbs using ion trap GC-MS/MS
    Sigrist, IA
    Manzardo, GGG
    Amadò, R
    BIOLOGICALLY-ACTIVE PHYTOCHEMICALS IN FOOD, 2001, (269): : 237 - 240
  • [19] Differentiation of the six dimethoxypyrovalerone regioisomers: GC-MS, GC-MS/MS and GC-IR
    Abiedalla, Younis
    DeRuiter, Jack
    Smith, Forrest
    Clark, C. Randall
    TALANTA, 2017, 171 : 220 - 228
  • [20] GC-MS
    HAYASHI, A