Complications associated with an implantable vascular access device

被引:55
作者
Dillon, Patrick A. [1 ]
Foglia, Robert P. [1 ]
机构
[1] Washington Univ, Sch Med, St Louis Childrens Hosp, Dept Surg,Div Pediat Surg, St Louis, MO 63110 USA
关键词
portacath; vascular access; complications; children;
D O I
10.1016/j.jpedsurg.2006.05.022
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Purpose: Implantable vascular access devices (ports) are well accepted in the management of many pediatric conditions. Modifications have improved port function, patient satisfaction, and enhanced compatibility with imaging studies. We reviewed our experience with a port system and identified unique mechanical complications. Methods: From 1998 to the present, 301 patients underwent 296 port insertions and 175 port removals. We assessed medical records, radiographs, and operative findings. The 6.6F MRI Low-Profile Implanted Port (Bard Access Systems, Salt Lake City, Utah) was used almost exclusively and was assembled by the operating surgeon. Outcome measures included port reservoir leakage, catheter dislodgment, and number of device days until complication. Ports were implanted for multiple medical problems including 74.2% in hematology/oncology patients. Results: For 296 port insertions, 15 complications (5.1%) were identified in 13 patients (mean age, 8.4 years). Eleven leaks (3.7%) in 9 patients were found, with 9 leaks resulting from needle perforation of the port base and 2 leaks seen at the catheter connection site. Average port duration was 425 days (range, 12-1266 days) before leakage. Four patients had catheter dislodgment (1.4%), with 3 of 4 catheters embolizing to the heart or pulmonary artery. Patients were asymptomatic, and catheters were retrieved by interventional radiology. Dislodgment at the catheter-port connection site was seen in 3 of 4 cases, and average port duration was 1075 days (range, 269-2657 days) until catheter separation. Twelve of 13 patients had successful implantation of a new port system. Conclusions: This study identifies that (1) mechanical port complications (5.1%) are not rare for this device; (2) regardless of port age, the thin plastic base may result in a risk of perforation not seen in other devices; (3) the extended period before embolization likely indicates device wear rather than faulty assembly; and (4) complications could be successfully managed including retrieval of embolized catheters. (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:1582 / 1587
页数:6
相关论文
共 26 条
[1]   THE PINCH-OFF SIGN - A WARNING OF IMPENDING PROBLEMS WITH PERMANENT SUBCLAVIAN CATHETERS [J].
AITKEN, DR ;
MINTON, JP .
AMERICAN JOURNAL OF SURGERY, 1984, 148 (05) :633-636
[2]   Percutaneous retrieval of central venous catheter fragments [J].
Andrews, RE ;
Tulloh, RMR ;
Rigby, ML .
ARCHIVES OF DISEASE IN CHILDHOOD, 2002, 87 (02) :149-150
[3]   Implanted vascular access devices (ports) in children: complications and their prevention [J].
Babu, R ;
Spicer, RD .
PEDIATRIC SURGERY INTERNATIONAL, 2002, 18 (01) :50-53
[4]   Experience at a single institution with endovascular treatment of mechanical complications caused by implanted central venous access devices in pediatric and adult patients [J].
Bessoud, B ;
de Baere, T ;
Kuoch, V ;
Desruennes, E ;
Cosset, MF ;
Lassau, N ;
Roche, A .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 180 (02) :527-532
[5]  
BRINCKER H, 1986, CANCER, V57, P1124, DOI 10.1002/1097-0142(19860315)57:6<1124::AID-CNCR2820570611>3.0.CO
[6]  
2-D
[7]  
BROVIAC JW, 1973, SURG GYNECOL OBSTET, V136, P602
[8]   Ventricular tachycardia secondary to Port-a-Cath® fracture and embolization [J].
Denny, MA ;
Frank, LR .
JOURNAL OF EMERGENCY MEDICINE, 2003, 24 (01) :29-34
[9]   EVALUATION OF CURRENT TECHNIQUES FOR NON-SURGICAL REMOVAL OF INTRA-VASCULAR IATROGENIC FOREIGN-BODIES [J].
FISHER, RG ;
FERREYRO, R .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1978, 130 (03) :541-548
[10]  
Klotz HP, 1996, J SURG ONCOL, V62, P222, DOI 10.1002/(SICI)1096-9098(199607)62:3<222::AID-JSO14>3.0.CO