Retrieval of the Extraction Solvent by Magnetic Particles for Dispersive Liquid-Liquid Microextraction of UV Filters

被引:5
作者
Zhang, Ting [1 ]
Guo, Jun-Fang [2 ]
Bai, Li [3 ]
Shi, Zhi-Guo [3 ]
Qi, Li-Ming [4 ]
机构
[1] Shandong Acad Sci, Inst Oceanog Instrumentat, Shandong Prov Key Lab Ocean Environm Monitoring T, Qingdao 266001, Peoples R China
[2] Wuhan Inst Technol, Sch Mat Sci Engn, Wuhan, Peoples R China
[3] Wuhan Univ, Dept Chem, Wuhan 430072, Peoples R China
[4] Inst Sci Mer Rimouski, Rimouski, PQ, Canada
关键词
UV filters; magnetic particles; DLLME; environmental samples; extraction solvent; HPLC; BAR SORPTIVE EXTRACTION; SOLID-PHASE EXTRACTION; POLYCYCLIC AROMATIC-HYDROCARBONS; CHROMATOGRAPHY-MASS-SPECTROMETRY; WATER SAMPLES; SENSITIVE DETERMINATION; BATHING WATERS; DIODE-ARRAY; BENZOPHENONE; SUNSCREENS;
D O I
10.1080/10826076.2014.883538
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple dispersive liquid-liquid microextraction (DLLME) method, based on retrieval of the extraction solvent by magnetic particles and followed by HPLC-UV analysis, was proposed for the determination of UV filters in environmental water samples. The new method uses vortex agitation in the DLLME process to achieve rapid equilibrium. Another feature of the proposed method is that the retrieval of the extraction solvent is accomplished by functionalized magnetic particles rather than by special designed vessels or refrigeration and thawing process associated with DLLME when low-density extraction solvent was used. The parameters that may influence the extraction, including vortex time, volume of extraction solvent, weight of the magnetic particles, volume of desorption solvent, pH, and ionic concentration of the sample solution, were investigated in detail. Under the optimized conditions, the limits of detection for the target UV filters were in range of 0.7-12.3ngmL(-1). The results also demonstrated good linearity and precision, with the regression coefficients above 0.9989 and the RSDs below 4.4%, respectively.
引用
收藏
页码:104 / 110
页数:7
相关论文
共 42 条
[1]   On-line sequential injection dispersive liquid-liquid microextraction system for flame atomic absorption spectrometric determination of copper and lead in water samples [J].
Anthemidis, Aristidis N. ;
Ioannou, Kallirroy-Ioanna G. .
TALANTA, 2009, 79 (01) :86-91
[2]   Low-density extraction solvent-based solvent terminated dispersive liquid-liquid microextraction combined with gas chromatography-tandem mass spectrometry for the determination of carbamate pesticides in water samples [J].
Chen, Hao ;
Chen, Ruiwen ;
Li, Shengqing .
JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (08) :1244-1248
[3]   Determination of the UV filters worldwide authorised in sunscreens by high-performance liquid chromatography -: Use of cyclodextrins as mobile phase modifier [J].
Chisvert, A ;
Pascual-Martí, MC ;
Salvador, A .
JOURNAL OF CHROMATOGRAPHY A, 2001, 921 (02) :207-215
[4]   One-step in-syringe ionic liquid-based dispersive liquid-liquid microextraction [J].
Cruz-Vera, Marta ;
Lucena, Rafael ;
Cardenas, Soledad ;
Valcarcel, Miguel .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (37) :6459-6465
[5]   Determination of UV filters and antimicrobial agents in environmental water samples [J].
Cuderman, Petra ;
Heath, Ester .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 387 (04) :1343-1350
[6]   Monodisperse magnetic single-crystal ferrite microspheres [J].
Deng, H ;
Li, XL ;
Peng, Q ;
Wang, X ;
Chen, JP ;
Li, YD .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2005, 44 (18) :2782-2785
[7]   Organic UV filters and their photodegradates, metabolites and disinfection by-products in the aquatic environment [J].
Diaz-Cruz, M. Silvia ;
Llorca, Marta ;
Barcelo, Damia .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2008, 27 (10) :873-887
[8]   Dispersive liquid-liquid microextraction using extraction solvent lighter than water [J].
Farajzadeh, Mir Ali ;
Seyedi, Seyed Esmaeil ;
Shalamzari, Mohammad Safi ;
Bamorowat, Mehdi .
JOURNAL OF SEPARATION SCIENCE, 2009, 32 (18) :3191-3200
[9]   UV filters: From sunscreens to human body and the environment [J].
Giokas, Dimosthenis L. ;
Salvador, Amparo ;
Chisvert, Alberto .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2007, 26 (05) :360-374
[10]   Determination of UV-filter residues in bathing waters by liquid chromatography UV-diode array and gas chromatography mass spectrometry after micelle mediated extraction-solvent back extraction [J].
Giokas, DL ;
Sakkas, VA ;
Albanis, TA ;
Lampropoulou, DA .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1077 (01) :19-27