Magnetic resonance-guided focused ultrasound surgery (MRgFUS): Ablation of liver tissue in a porcine model

被引:52
作者
Kopelman, Doron [1 ]
Inbar, Yael
Hanannel, Arik
Freundlich, David
Castel, David
Perel, Azriel
Greenfeld, Adrian
Salamon, Tal
Sareli, Merab
Valeanu, Adrian
Papa, Moshe
机构
[1] HaEmek Med Ctr, Dept Surg B, Afula, Israel
[2] Technion Israel Inst Technol, IL-32000 Haifa, Israel
[3] Chaim Sheba Med Ctr, Focused Ultrasound Treatment Ctr, Tel Hashomer, Israel
[4] InSightec Ltd, Tirat Karmel, Israel
[5] Tel Aviv Univ, Sheba Med Ctr, Dept Anesthesiol & Intens Care, IL-52621 Tel Hashomer, Israel
[6] Tel Aviv Univ, Sheba Med Ctr, Dept Surg, IL-52621 Tel Hashomer, Israel
关键词
liver ablation; magnetic resonance-guided focused ultrasound surgery; animal experiment;
D O I
10.1016/j.ejrad.2006.04.008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Liver surgery is technically demanding and is considered a major procedure with relatively high morbidity rates. Magnetic resonance-guided focused ultrasound surgery (MRgFUS) uses focused ultrasonic energy to create a heat coagulation lesion, which can be achieved in a totally controlled, very accurate manner (< 1 mm). The aim of this study was to evaluate the safety and accuracy of non-invasive focal ablation of liver tissue achieved by consecutive MRgFUS sonications. Materials and methods: Six MRgFUS procedures were performed in five pigs under general anesthesia, with the ExAblate 2000 system (InSightec, Israel). Real-time imaging and temperature mapping (Signa Twinspeed 1.5T, GEHC, USA) enabled the immediate evaluation of the results of each sonication. Different foci were chosen within the liver. These mock lesions were ablated by several sonications, each of them performed during 20-30 s of apnea. Between sonications, the pigs were normally ventilated. The pigs were sacrificed 3-21 days after the procedure and their livers were examined. Results: The MRgFUS created complete tissue destruction of mock lesions in different areas of the pig's liver. The lesion sizes in each animal varied according to the number of sonications used and the extent of overlap between adjacent sonications. The lesion ranged in size from 1.5 cm x 1.5 cm x 2.0 cm to 5.5 cm x 4.5 cm x 2.0 cm. There was no morbidity. Conclusions: MRgFUS under general anesthesia is a safe, completely non-invasive technology for the ablation of liver tissue. Liver tissue can be ablated in a very accurate manner, based on the pre-treatment planning on the MR images. The MR imaging characteristics, including real-time temperature mapping, enable real-time control of every step of the ablation process. Mechanical ventilation with intermittent periods of apnea is a technique that overcomes the problem of the respiratory movements of the liver. (c) 2006 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:157 / 162
页数:6
相关论文
共 24 条
  • [11] A new method for the generation and use of focused ultrasound in experimental biology
    Lynn, JG
    Zwemer, RL
    Chick, AJ
    Miller, AE
    [J]. JOURNAL OF GENERAL PHYSIOLOGY, 1942, 26 (02) : 179 - 193
  • [12] Percutaneous MR imaging-guided laser-induced thermotherapy of hepatic metastases
    Mack, MG
    Straub, R
    Eichler, K
    Engelmann, K
    Zangos, S
    Roggan, A
    Woitaschek, D
    Böttger, M
    Vogl, TJ
    [J]. ABDOMINAL IMAGING, 2001, 26 (04): : 369 - 374
  • [13] MCCALL JL, 1995, BRIT J HOSP MED, V54, P378
  • [14] Comparison of resection and radiofrequency ablation for treatment of solitary colorectal liver metastases
    Oshowo, A
    Gillams, A
    Harrison, E
    Lees, WR
    Taylor, I
    [J]. BRITISH JOURNAL OF SURGERY, 2003, 90 (10) : 1240 - 1243
  • [15] PARKIN DM, 1992, IARC PUBLICATION, V120
  • [16] EXTRACORPOREAL HIGH-INTENSITY FOCUSED ULTRASOUND FOR VX2 LIVER-TUMORS IN THE RABBIT
    PRAT, F
    CENTARTI, M
    SIBILLE, A
    ELFADIL, FA
    HENRY, L
    CHAPELON, JY
    CATHIGNOL, D
    [J]. HEPATOLOGY, 1995, 21 (03) : 832 - 836
  • [17] THERMAL DOSE DETERMINATION IN CANCER-THERAPY
    SAPARETO, SA
    DEWEY, WC
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1984, 10 (06): : 787 - 800
  • [18] MR imaging-guided focused ultrasound surgery of uterine leiomyomas: A feasibility study
    Tempany, CMC
    Stewart, EA
    McDannold, N
    Quade, BJ
    Jolesz, FA
    Hynynen, K
    [J]. RADIOLOGY, 2003, 226 (03) : 897 - 905
  • [19] FOCUSED EXTRACORPOREAL PYROTHERAPY - FEASIBILITY STUDY IN MAN
    VALLANCIEN, G
    HAROUNI, M
    VEILLON, B
    MOMBET, A
    PRAPOTNICH, D
    BRISSET, JM
    BOUGARAN, J
    [J]. JOURNAL OF ENDOUROLOGY, 1992, 6 (02) : 173 - 181
  • [20] Visioli A G, 1999, Eur J Ultrasound, V9, P11, DOI 10.1016/S0929-8266(99)00009-9