Time-resolved diagnostics for concrete target response

被引:3
|
作者
Baum, DW
Kuklo, RM
Reaugh, JE
Simonson, SC
机构
关键词
D O I
10.1016/S0734-743X(97)87483-0
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
In order to facilitate the design of advanced penetrating weapons for defeating land targets, the interaction of concrete with high-velocity penetrators needs to be better characterized. To aid in this effort, three new types of time-resolved diagnostics are being developed and have been used in two experiments and one demonstration: fiber optic arrays to localize penetrators in space and time, Fabry-Perot velocimetry to record the concrete particle velocity, which is related to the pressure, at specific locations within concrete targets, and micropower impulse radar to provide a non-intrusive measure of the penetrator position-time history in a target. The two experiments used the fiber optic array and the Fabry-Perot velocimeter to diagnose the response of concrete to penetration by a Viper shaped charge jet. The results were analyzed using the CALE continuum mechanics simulation program, for which a preliminary model of the material properties of concrete was developed. The fiber optic arrays recorded the bow shock at locations 6.4 and 16.9 cm from the front surfaces. The Fabry-Perot velocimeter measured a free-surface velocity of 0.13 km/s at a distance of 3 cm and obliquity 70 degrees from the jet, which was moving at an interface velocity of 4.0 km/s at a depth of 29 cm. These values imply a pressure of about 6.6 kbar at that location. The demonstration used micropower impulse radar with a pulse repetition frequency of 0.25 MHz and a cell size of 30 ps to detect and record the motion of a metal penetrator simulant moving inside a cylindrical concrete target.
引用
收藏
页码:93 / 100
页数:8
相关论文
共 50 条
  • [1] Time-resolved diagnostic for concrete target response
    Lawrence Livermore Natl Lab, Livermore, United States
    Int J Impact Eng, 1 -5 pt 1 (93-100):
  • [2] TIME-RESOLVED TRANSILLUMINATION FOR MEDICAL DIAGNOSTICS
    ANDERSSONENGELS, S
    BERG, R
    SVANBERG, S
    JARLMAN, O
    OPTICS LETTERS, 1990, 15 (21) : 1179 - 1181
  • [3] Time-resolved diagnostics of a bipolar HiPIMS discharge
    Hippler, Rainer
    Cada, Martin
    Hubicka, Zdenek
    JOURNAL OF APPLIED PHYSICS, 2020, 127 (20)
  • [4] Time-resolved opto-acoustic diagnostics of tissue
    Karabutov, AA
    Podymova, NB
    IZVESTIYA AKADEMII NAUK SERIYA FIZICHESKAYA, 1997, 61 (08): : 1580 - 1585
  • [5] A PULSE STACKER FOR TIME-RESOLVED LASER PLASMA DIAGNOSTICS
    DANSON, CN
    EDWARDS, CB
    ROSS, IN
    OPTICS AND LASER TECHNOLOGY, 1985, 17 (02): : 99 - 101
  • [6] Global and target analysis of time-resolved spectra
    van Stokkum, IHM
    Larsen, DS
    van Grondelle, R
    BIOCHIMICA ET BIOPHYSICA ACTA-BIOENERGETICS, 2004, 1657 (2-3): : 82 - 104
  • [7] TIME-RESOLVED OPTICAL DIAGNOSTICS OF RADIO-FREQUENCY PLASMAS
    GOTTSCHO, RA
    MANDICH, ML
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1985, 3 (03): : 617 - 624
  • [8] TIME-RESOLVED PLASMA DIAGNOSTICS USING A NEUTRON PINHOLE CAMERA
    BAUER, RW
    WEINGART, RC
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1976, 21 (05): : 851 - 851
  • [9] TIME-RESOLVED LASER DIAGNOSTICS ON PULSED LASER PYROLYSIS OF METHANE
    GRAF, HP
    KNEUBUEHL, FK
    APPLIED PHYSICS B-PHOTOPHYSICS AND LASER CHEMISTRY, 1982, 28 (2-3): : 224 - 225
  • [10] Diagnostics of heterogeneous processes with the participation of radicals by time-resolved actinometry
    D. V. Lopaev
    A. V. Smirnov
    Plasma Physics Reports, 2004, 30 : 882 - 893