Common two-dimensional echocardiographic estimates of aortic linear dimensions are interchangeable

被引:7
作者
Georgiev, Ranko [1 ]
Rishniw, Mark [2 ,3 ]
Ljungvall, Ingrid [4 ]
Summerfield, Nuala
机构
[1] Cent Vet Clin, Sofia, Bulgaria
[2] Cornell Univ, Dept Clin Sci, Ithaca, NY 14853 USA
[3] Vet Informat Network, Davis, CA 95616 USA
[4] Swedish Univ Agr Sci, Dept Clin Sci, Uppsala, Sweden
关键词
Aorta; Echocardiography; Measurement; Dog; Cat; RATIO INDEXES; LEFT ATRIAL; DOGS;
D O I
10.1016/j.jvc.2013.02.002
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective: To compare two echocardiographic methods of measuring aortic diameter in short-axis projections. Methods: Right-parasternal short-axis 2-dimensional projections of the left atrium and aorta were obtained from dogs and cats undergoing routine cardiac evaluation. Two investigators measured the aortic valve linear dimension using 2 methods: along the commissure between the non-coronary and right-coronary cusps and along the commissure between the non-coronary and left-coronary cusps. Interobserver and intra-observer variability and agreement were assessed by comparing blinded measurements with each method by 4 trained observers on a standardized set of images. Measurements were compared for agreement using the limits of agreement analysis. Variability between observers was compared by examining residuals and intraclass correlation. Results: 274 canine and 100 feline aortic valve images were measured in the first part of the study. One observer demonstrated slight proportional bias, while the other observer showed more variability (less agreement). When results were pooled for both investigators, no bias was identified, and 95% limits of agreement were +/- 10% of the mean measurement for both species. In the second part of the study, 106 images were measured. Intraobserver variability was <4% for all observers. Inter-observer agreement was very high. Individual bias was identified in some observers, but was considered clinically inconsequential. Normalized differences between the 2 methods of measurement were below +/- 15% of the measured value for all observers. Conclusions: Our results show sufficient agreement between two common methods used to measure aortic linear dimensions to suggest that these methods are interchangeable. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:131 / 138
页数:8
相关论文
共 10 条
[1]  
Abbott JA, 2006, J VET INTERN MED, V20, P111, DOI 10.1892/0891-6640(2006)20[111:TEAOTF]2.0.CO
[2]  
2
[3]  
Brown DJ, 2005, J VET INTERN MED, V19, P542, DOI 10.1892/0891-6640(2005)19[542:QEEOME]2.0.CO
[4]  
2
[5]  
Brown DJ, 2003, J VET INTERN MED, V17, P653, DOI 10.1892/0891-6640(2003)017<0653:MERIIN>2.3.CO
[6]  
2
[7]  
Hall Daniel J, 2008, J Vet Cardiol, V10, P11, DOI 10.1016/j.jvc.2008.03.001
[8]   Left atrial to aortic root indices using two-dimensional and M-mode echocardiography in cavalier King Charles spaniels with and without left atrial enlargement [J].
Hansson, K ;
Häggström, J ;
Kvart, C ;
Lord, P .
VETERINARY RADIOLOGY & ULTRASOUND, 2002, 43 (06) :568-+
[9]  
Rishniw M, 2000, J VET INTERN MED, V14, P429, DOI 10.1892/0891-6640(2000)014<0429:EOFEMO>2.3.CO
[10]  
2