摘要
Introduction: Research of acute cardiac allograft rejection (ACAR) is important in PT (PT) care. A new method evaluates the ACAR based on the ventricular evoked response using pacemakers and fractal coated leads. We evaluated the long-term results, calculating sensitivity (SE), specificity (SP) and accuracy (AC). Materials and Methods: 30 PTs were analised. The electrograms (ELT) were recorded with CHARM protocol (Computerized Heart Acute Rejection Monitoring) and transferred by Internet. Results: A total of 1384 ELT have recorded in the course of 346 examinations. A SE of 81,8%, a SP of 100% and an AC of 94,9% were obtained. Conclusion: A good diagnostic performance was achieved. The calculated SE and SP are comparable with traditional endomyocardial biopsies (EMB).
引用
收藏
页码:507 / 512
页数:6
相关论文
共 50 条
  • [41] RETROSPECTIVE EVALUATION OF HOME INITIATION FOR LONG-TERM NON-INVASIVE VENTILATORY SUPPORT
    Palmer, J. M.
    Hughes, P. D.
    THORAX, 2009, 64 : A79 - A79
  • [42] NON-INVASIVE EVALUATION OF HEART MURMURS IN CHILDREN - REPLY
    NEWBURGER, JW
    MIETTINEN, OS
    NEW ENGLAND JOURNAL OF MEDICINE, 1983, 308 (21) : 1291 - 1291
  • [43] PRELIMINARY RESULTS OF A SYSTEMATIC REVIEW ON DIAGNOSTIC ACCURACY AND CLINICAL VALUE OF LONG TERM VIDEO-EEG MONITORING IN NON-INVASIVE PRESURGICAL EVALUATION OF PATIENTS WITH EPILEPSY
    Kobulashvili, T.
    Kuchukhidze, G.
    Brigo, F.
    Zimmermann, G.
    Hoefler, J.
    Leitinger, M.
    Dobesberger, J.
    Kalss, G.
    Rohracher, A.
    Neuray, C.
    Wakonig, A.
    Ernst, F.
    Hamed, J.
    Trinka, E.
    EPILEPSIA, 2016, 57 : 43 - 43
  • [44] Towards Long-term Non-invasive Monitoring for Epilepsy via Wearable EEG Devices
    Ingolfsson, Thorir Mar
    Cossettini, Andrea
    Wang, Xiaying
    Tabanelli, Enrico
    Tagliavini, Giuseppe
    Ryvlin, Philippe
    Benini, Luca
    Benatti, Simone
    2021 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (IEEE BIOCAS 2021), 2021,
  • [45] A Non-Invasive Technique for Long-Term Monitoring of Gastroesophageal Reflux-A Pilot Study
    Laracca, Marco
    Miele, Gianfranco
    Podesta, Luca
    Sangiovanni, Silvia
    SENSORS, 2023, 23 (23)
  • [46] Invasive versus non-invasive hemodynamic monitoring of heart failure patients and their outcomes
    Fadi Kandah
    Pooja Dhruva
    Raj Shukla
    Maedeh Ganji
    Carlos Palacio
    Emil Missov
    Jose Ruiz-Morales
    Journal of Geriatric Cardiology, 2022, 19 (04) : 315 - 318
  • [47] Non-invasive Cardiac Output Monitoring in Congenital Heart Disease
    Tandon A.
    Bhattacharya S.
    Morca A.
    Inan O.T.
    Munther D.S.
    Ryan S.D.
    Latifi S.Q.
    Lu N.
    Lasa J.J.
    Marino B.S.
    Baloglu O.
    Current Treatment Options in Pediatrics, 2023, 9 (4) : 247 - 259
  • [48] Invasive versus non-invasive hemodynamic monitoring of heart failure patients and their outcomes
    Kandah, Fadi
    Dhruva, Pooja
    Shukla, Raj
    Ganji, Maedeh
    Palacio, Carlos
    Missov, Emil
    Ruiz-Morales, Jose
    JOURNAL OF GERIATRIC CARDIOLOGY, 2022, 19 (04) : 315 - 318
  • [49] Heart patient health monitoring system using invasive and non-invasive measurement
    Mastoi, Qurat-ul-Ain
    Alqahtani, Ali
    Almakdi, Sultan
    Sulaiman, Adel
    Rajab, Adel
    Shaikh, Asadullah
    Alqhtani, Samar M.
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [50] Invasive versus non-invasive hemodynamic monitoring of heart failure patients and their outcomes
    Fadi Kandah
    Pooja Dhruva
    Raj Shukla
    Maedeh Ganji
    Carlos Palacio
    Emil Missov
    Jose RuizMorales
    Journal of Geriatric Cardiology, 2022, 19 (04) : 315 - 318