Evaluation of non-invasive monitoring after heart transplant - Long term results

被引:0
|
作者
Brofman, PR [1 ]
Bauer, V [1 ]
Milani, R [1 ]
Giffhorn, H [1 ]
Poffo, R [1 ]
Zarza, RQ [1 ]
Hutten, H [1 ]
Schreier, G [1 ]
Schaldach, M [1 ]
机构
[1] Hosp Univ Cajuru, PUC PR, Curitiba, Parana, Brazil
来源
EUROPACE 2001 | 2001年
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Research of acute cardiac allograft rejection (ACAR) is important in PT (PT) care. A new method evaluates the ACAR based on the ventricular evoked response using pacemakers and fractal coated leads. We evaluated the long-term results, calculating sensitivity (SE), specificity (SP) and accuracy (AC). Materials and Methods: 30 PTs were analised. The electrograms (ELT) were recorded with CHARM protocol (Computerized Heart Acute Rejection Monitoring) and transferred by Internet. Results: A total of 1384 ELT have recorded in the course of 346 examinations. A SE of 81,8%, a SP of 100% and an AC of 94,9% were obtained. Conclusion: A good diagnostic performance was achieved. The calculated SE and SP are comparable with traditional endomyocardial biopsies (EMB).
引用
收藏
页码:507 / 512
页数:6
相关论文
共 50 条
  • [21] Non-invasive Techniques for Heart Rate Monitoring: A Review
    Naik, Rasika
    Jadhav, Manjiri
    Mahankuda, Puja
    Gupta, Bhoomi
    SMART TRENDS IN COMPUTING AND COMMUNICATIONS, VOL 3, SMARTCOM 2024, 2024, 947 : 263 - 273
  • [22] Non-invasive monitoring of avian embryo heart rate
    Andrianov, Evgenii Aleksandrovich
    Sudakov, Alexander Nikolaevich
    Andriano, Aleksei Aleksandrovich
    Skolznev, Nikolay Yakovlevich
    JOURNAL OF ANIMAL BEHAVIOUR AND BIOMETEOROLOGY, 2019, 7 (03): : 119 - 122
  • [23] Calprotectin - A useful non-invasive marker for intestinal transplant monitoring
    Sudan, D
    Dijkstra, G
    Torres, C
    Ploeg, R
    Sun, Y
    AMERICAN JOURNAL OF TRANSPLANTATION, 2005, 5 : 230 - 231
  • [24] Non-invasive haemodynamic monitoring in renal transplant: a feasibility study
    Naji, S.
    Fabes, J.
    Hadi, D.
    Berry, P.
    Wittenberg, M.
    ANAESTHESIA, 2019, 74 : 35 - 35
  • [25] NON-INVASIVE AND INVASIVE MONITORING AFTER ACVB-OPERATION
    DEEG, P
    SCHAD, N
    HAUBITZ, I
    EMDE, EVD
    SCHNEIDER, KW
    ZEITSCHRIFT FUR KARDIOLOGIE, 1980, 69 (03): : 228 - 228
  • [26] Non-invasive telemonitorization in patients with chronic heart failure: long-term benefits
    Sara Couto Pereira, S.
    Nunes-Ferreira, A.
    Silverio Antonio, P.
    Brito, J.
    Gregorio, C.
    Silva, B.
    Alves Da Silva, P.
    Rigueira, J.
    Santos, R.
    Agostinho, J. R.
    Rodrigues, T.
    Cunha, N.
    Pinto, Fj
    Brito, D.
    EUROPEAN JOURNAL OF HEART FAILURE, 2022, 24 : 133 - 134
  • [27] NON-INVASIVE MONITORING IN THE PATIENT WITH HEART-DISEASE
    GRAVENSTEIN, JS
    CLEVELAND CLINIC QUARTERLY, 1981, 48 (01): : 37 - 43
  • [28] NON-INVASIVE MONITORING
    Turmelle, Michael
    JOURNAL OF HOSPITAL MEDICINE, 2010, 5 : 58 - 58
  • [29] Database management expert program for integrated evaluation of non-invasive and invasive results of coronary heart disease
    Koszegi, Z
    Balogh, E
    Balkay, L
    Varga, J
    Galuska, L
    Jenei, C
    Apro, D
    Edes, I
    COMPUTERS IN CARDIOLOGY 2003, VOL 30, 2003, 30 : 275 - 278
  • [30] A heart transplant after total artificial heart support: initial and long-term results
    David, Charles-Henri
    Lacoste, Philippe
    Nanjaiah, Prakash
    Bizouarn, Philippe
    Lepoivre, Thierry
    Michel, Magali
    Pattier, Sabine
    Toquet, Claire
    Perigaud, Christian
    Mugniot, Antoine
    Al Habash, Ousama
    Petit, Thierry
    Groleau, Nicolas
    Rozec, Bertrand
    Trochu, Jean Noel
    Roussel, Jean Christian
    Senage, Thomas
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2020, 58 (06) : 1175 - 1181