An efficient wavenumber algorithm towards real-time ultrasonic full-matrix imaging of multi-layered medium

被引:40
作者
Jin, Haoran [1 ]
Chen, Jian [1 ]
机构
[1] Zhejiang Univ, Sch Mech Engn, State Key Lab Fluid Power & Mechatron Syst, Hangzhou 310027, Peoples R China
基金
中国国家自然科学基金;
关键词
Full-matrix imaging; Wavenumber algorithm; Multi-layered medium; Total focusing method; Phased array; SHIFT MIGRATION; LAYERED OBJECTS; ARRAY DATA; CAPTURE;
D O I
10.1016/j.ymssp.2020.107149
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Ultrasonic full-matrix imaging can sense small defects in non-destructive evaluation using full-matrix capture (FMC). However, the accompanying heavy computational burden limits FMC's applications, especially for real-time scenarios. Currently, the full-matrix imaging for homogeneous medium has progressively advanced, but these algorithms become inaccu-rate and inefficient for the multi-layered medium. To overcome this problem, an efficient wavenumber algorithm for ultrasonic full-matrix imaging of multi-layered medium is proposed in this paper. The proposed method utilises wavefield extrapolation to migrate the transmitting and receiving transducers virtually to the interfaces between different layers. It then reconstructs the image of each layer with Stolt interpolation. The proposed method is developed based on a wave model, and thus is more rigorous than the ray-based theory in mathematics. Moreover, the calculation in the wavenumber domain dramatically reduces the computational cost. In comparison with well-established root-mean-square based total focusing method and extended phase shift migration, the proposed method performed better in terms of imaging quality and efficiency in the simulations and experiments. Specifically, it achieves 6-10 Hz imaging frame rates for ultrasonic full-matrix imaging of multi-layered medium using a 64-element phased array, and may find various real-time imaging applications in practice. (c) 2020 Published by Elsevier Ltd.
引用
收藏
页数:11
相关论文
共 35 条
[1]   Modeling of phased array transducers [J].
Ahmad, R ;
Kundu, T ;
Placko, D .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2005, 117 (04) :1762-1776
[2]  
Brekhovskikh LM, 2012, WAVES LAYERED MEDIA
[3]  
Chew W. C., 1995, WAVES FIELDS INHOMOG
[4]   Ultrasonic arrays for non-destructive evaluation: A review [J].
Drinkwater, Bruce W. ;
Wilcox, Paul D. .
NDT & E INTERNATIONAL, 2006, 39 (07) :525-541
[5]   4D in vivo ultrafast ultrasound imaging using a row-column addressed matrix and coherently-compounded orthogonal plane waves [J].
Flesch, M. ;
Pernot, M. ;
Provost, J. ;
Ferin, G. ;
Nguyen-Dinh, A. ;
Tanter, M. ;
Deffieux, T. .
PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (11) :4571-4588
[6]  
Gao XS, 2016, 2016 ASIA-PACIFIC CONFERENCE ON INTELLIGENT ROBOT SYSTEMS (ACIRS 2016), P16, DOI 10.1109/ACIRS.2016.7556180
[7]   Stolt's f-k Migration for Plane Wave Ultrasound Imaging [J].
Garcia, Damien ;
Le Tarnec, Louis ;
Muth, Stephan ;
Montagnon, Emmanuel ;
Poree, Jonathan ;
Cloutier, Guy .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2013, 60 (09) :1853-1867
[8]  
Harlan William, 1982, SEP30, V103, P110
[9]   Post-processing of the full matrix of ultrasonic transmit-receive array data for non-destructive evaluation [J].
Holmes, C ;
Drinkwater, BW ;
Wilcox, PD .
NDT & E INTERNATIONAL, 2005, 38 (08) :701-711
[10]   The post-processing of ultrasonic array data using the total focusing method [J].
Holmes, C ;
Drinkwater, BW ;
Wilcox, P .
INSIGHT, 2004, 46 (11) :677-680