Reactive torque monitoring and cycling speed control of a belt-driven cycle ergometer

被引:6
作者
Hsueh, Po-Wen [1 ]
Tsai, Mi-Ching [1 ]
机构
[1] Natl Cheng Kung Univ, Dept Mech Engn, Tainan 701, Taiwan
关键词
Cycle ergometer; State observer; Reactive torque estimation; Resonant attenuation; Lower limb rehabilitation; Impedance model; MOTION CONTROL; ASHWORTH;
D O I
10.1016/j.conengprac.2013.07.002
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The lower limb cycle ergometer driven by a motor is a typical rehabilitation-assistive device for hemiparetic patients with abnormal muscle tone in their lower limbs. Since unusual muscle tone may cause excessive spasticity during rehabilitation, it is important to monitor reactive torques produced primarily by the abnormal muscle tone. Thus, this study investigated a state observer design applied to a belt-driven ergometer, where the motor current and position information were used to estimate reliable reactive torque. A dual feedback control loop was proposed to improve the resonance caused by the belt-driven structure and stabilize the cycling speed in the cycle rehabilitated device; meanwhile, the impedance model constructed by the feedback control loop is presented to generate the compliance characteristic for stably and gently controlling the speed response affected by reactive torque. Simulation and experiments of the belt-driven ergometer were conducted with results validating the effectiveness of the proposed control scheme in terms of stable cycle speed and observer performance. Crown Copyright (C) 2013 Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1564 / 1576
页数:13
相关论文
共 24 条
[11]  
Johnson M. A., 2004, PID CONTROL
[12]  
Kwon TS, 2005, APPL POWER ELECT CO, P1035
[13]   Assessment of a portable device for the quantitative measurement of ankle joint stiffness in spastic individuals [J].
Lorentzen, Jakob ;
Grey, Michael J. ;
Geertsen, Svend S. ;
Biering-Sorensen, Fin ;
Brunton, Kelly ;
Gorassini, Monica ;
Nielsen, Jens Bo .
CLINICAL NEUROPHYSIOLOGY, 2012, 123 (07) :1371-1382
[14]  
Mazzocchio R, 2008, NEUROREHABILITATION, V23, P67
[15]  
Murakami T., 1993, Conference Record of the Power Conversion Conference - Yokohama 1993 (Cat. No.93TH0406-9), P352, DOI 10.1109/PCCON.1993.264158
[16]   High-performance control of dual-inertia servo-drive systems using low-cost integrated SAW torque transducers [J].
O'Sullivan, Tim M. ;
Bingham, Chris M. ;
Schofield, Nigel .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2006, 53 (04) :1226-1237
[17]   Spasticity and muscle contracture following stroke [J].
ODwyer, NJ ;
Ada, L ;
Neilson, PD .
BRAIN, 1996, 119 :1737-1749
[18]  
OHM DY, 1994, IEEE IND APPLIC SOC, P1923, DOI 10.1109/IAS.1994.377694
[19]   Motion control for advanced mechatronics [J].
Ohnishi, K ;
Shibata, M ;
Murakami, T .
IEEE-ASME TRANSACTIONS ON MECHATRONICS, 1996, 1 (01) :56-67
[20]   A review of the properties and limitations of the Ashworth and modified Ashworth Scales as measures of spasticity [J].
Pandyan, AD ;
Johnson, GR ;
Price, CIM ;
Curless, RH ;
Barnes, MP ;
Rodgers, H .
CLINICAL REHABILITATION, 1999, 13 (05) :373-383