Fluid flow induced by nonuniform ac electric fields in electrolytes on microelectrodes.: I.: Experimental measurements

被引:454
作者
Green, NG
Ramos, A
González, A
Morgan, H
Castellanos, A
机构
[1] Univ Sevilla, Dept Elect & Electromagnetismo, Fac Fis, Seville 41012, Spain
[2] ESI Univ Sevilla, Dept Fis Aplicada, Seville 41092, Spain
[3] Univ Glasgow, Bioelect Res Ctr, Dept Elect & Elect Engn, Glasgow G12 8LT, Lanark, Scotland
来源
PHYSICAL REVIEW E | 2000年 / 61卷 / 04期
关键词
D O I
10.1103/PhysRevE.61.4011
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
Under the influence of an ac electric field, electrolytes on planar microelectrodes exhibit fluid Row. The nonuniform electric field generated by the electrodes interacts with the suspending fluid through a number of mechanisms, giving rise to body forces and fluid flow. This paper presents the detailed experimental measurements of the velocity of fluid flow on microelectrodes at frequencies below the charge relaxation frequency of the electrolyte. The Velocity of latex tracer particles was measured as a function of applied signal frequency and potential, electrolyte conductivity, and position on the electrode surface. The data are discussed in terms of a linear model of ac electroosmosis: the interaction of the nonuniform ac field and the induced electrical double layer.
引用
收藏
页码:4011 / 4018
页数:8
相关论文
共 20 条
  • [1] Separation of submicrometre particles using a combination of dielectrophoretic and electrohydrodynamic forces
    Green, NG
    Morgan, H
    [J]. JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1998, 31 (07) : L25 - L30
  • [2] Manipulation and trapping of sub-micron bioparticles using dielectrophoresis
    Green, NG
    Morgan, H
    Milner, JJ
    [J]. JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 1997, 35 (02): : 89 - 102
  • [3] Dielectrophoretic investigations of sub-micrometre latex spheres
    Green, NG
    Morgan, H
    [J]. JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1997, 30 (18) : 2626 - 2633
  • [4] Dielectrophoretic separation of nano-particles
    Green, NG
    Morgan, H
    [J]. JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1997, 30 (11) : L41 - L44
  • [5] Dielectrophoresis of submicrometer latex spheres. 1. Experimental results
    Green, NG
    Morgan, H
    [J]. JOURNAL OF PHYSICAL CHEMISTRY B, 1999, 103 (01): : 41 - 50
  • [6] Grossman P.D., 1992, CAPILLARY ELECTROPHO
  • [7] Manipulation of herpes simplex virus type 1 by dielectrophoresis
    Hughes, MP
    Morgan, H
    Rixon, FJ
    Burt, JPH
    Pethig, R
    [J]. BIOCHIMICA ET BIOPHYSICA ACTA-GENERAL SUBJECTS, 1998, 1425 (01): : 119 - 126
  • [8] Lyklema J. J., 1995, FUNDAMENTALS INTERFA, V2
  • [9] Separation of submicron bioparticles by dielectrophoresis
    Morgan, H
    Hughes, MP
    Green, NG
    [J]. BIOPHYSICAL JOURNAL, 1999, 77 (01) : 516 - 525
  • [10] Trapping of micrometre and sub-micrometre particles by high-frequency electric fields and hydrodynamic forces
    Muller, T
    Gerardino, A
    Schnelle, T
    Shirley, SG
    Bordoni, F
    DeGasperis, G
    Leoni, R
    Fuhr, G
    [J]. JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1996, 29 (02) : 340 - 349